Last modified by Admin on 2026/04/02 13:49

From version 89.1
edited by Admin
on 2026/03/25 16:43
Change comment: Uploaded new attachment "1731517180930-597.png", version {1}
To version 88.2
edited by Admin
on 2026/03/25 16:42
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -138,37 +138,41 @@
138 138  [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]
139 139  
140 140  |**Pin**|**Name**|**Description**
141 -|**1**|**RS_LOGIC_A**|RS-485 line A for communication with BMS Logic
142 -|**2**|**RS_LOGIC_B**|RS-485 line B for communication with BMS Logic
141 +|**1**|**RS485_A**|RS-485 line A for communication with BMS Logic
142 +|**2**|**RS485_B**|RS-485 line B for communication with BMS Logic
143 143  |**3**|**+5V**|Supply voltage for BMS Logic
144 144  |**4**|**GND**|Ground
145 145  
146 -=== X12 – header for internal CAN interface ===
146 +=== X12 – header for high-voltage bus before contactors (minus) ===
147 147  
148 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030
148 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030
149 149  
150 -[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]
150 +[[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]]
151 151  
152 152  |**Pin**|**Name**|**Description**
153 -|**1**|**CAN_INT_H**|RS-485 line A for communication with BMS Logic
154 -|**2**|**CAN_INT_L**|RS-485 line B for communication with BMS Logic
155 -|**3**|**+5V**|Supply voltage for BMS Logic
156 -|**4**|**GND**|Ground
153 +|**1**|**IN1-**|Minus of the high-voltage bus (before contactors)
154 +|**2**|**IN1-**|Minus of the high-voltage bus (before contactors)
157 157  
158 -=== X13 – header for external CAN and RS-485 interfaces ===
156 +(% class="box warningmessage" %)
157 +(((
158 +The connected voltage must not exceed 1000V.
159 +)))
159 159  
160 -Receptacle Housing: Molex 430250600. Terminals: Molex 43030
161 +=== X13 – header for high-voltage bus after contactors (plus) ===
161 161  
162 -[[image:https://docs.movicomelectric.com/bin/download/Battery%20management%20systems/BMS%20Main%202.1/2.%20Installation%20and%20connection/WebHome/1731517180930-597.png?width=113&height=81&rev=1.1||alt="1731517180930-597.png" height="81" width="113"]]
163 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030
163 163  
165 +[[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]]
166 +
164 164  |**Pin**|**Name**|**Description**
165 -|**1**|**EXT_RS485_A**|RS-485 line A for communication with external equipment
166 -|**2**|**CAN_H**|CAN H line for communication with external equipment
167 -|**3**|**+5V_CAN**|Supply voltage 5V for external devices, max 200 mA
168 -|**4**|**EXT_RS485_B**|RS-485 line B for communication with external equipment
169 -|**5**|**CAN_L**|CAN L line for communication with external equipment
170 -|**6**|**GND_CAN**|Ground
168 +|**1**|**IN2+**|Plus of the high-voltage bus (after contactors)
169 +|**2**|**IN2+**|Plus of the high-voltage bus (after contactors)
171 171  
171 +(% class="box warningmessage" %)
172 +(((
173 +The connected voltage must not exceed 1000V.
174 +)))
175 +
172 172  === X14 – header for high-voltage bus after contactors (minus) ===
173 173  
174 174  Receptacle Housing: Molex 436450200. Terminals: Molex 43030