Changes for page 2. Installation and connection
Last modified by Admin on 2026/04/02 13:49
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -138,37 +138,41 @@ 138 138 [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 139 139 140 140 |**Pin**|**Name**|**Description** 141 -|**1**|**RS_ LOGIC_A**|RS-485 line A for communication with BMS Logic142 -|**2**|**RS_ LOGIC_B**|RS-485 line B for communication with BMS Logic141 +|**1**|**RS485_A**|RS-485 line A for communication with BMS Logic 142 +|**2**|**RS485_B**|RS-485 line B for communication with BMS Logic 143 143 |**3**|**+5V**|Supply voltage for BMS Logic 144 144 |**4**|**GND**|Ground 145 145 146 -=== X12 – header for i nternalCANinterface===146 +=== X12 – header for high-voltage bus before contactors (minus) === 147 147 148 -Receptacle Housing: Molex 4302 50400. Terminals: Molex 43030148 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 149 149 150 -[[image:173 2198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]150 +[[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 151 151 152 152 |**Pin**|**Name**|**Description** 153 -|**1**|**CAN_INT_H**|RS-485 line A for communication with BMS Logic 154 -|**2**|**CAN_INT_L**|RS-485 line B for communication with BMS Logic 155 -|**3**|**+5V**|Supply voltage for BMS Logic 156 -|**4**|**GND**|Ground 153 +|**1**|**IN1-**|Minus of the high-voltage bus (before contactors) 154 +|**2**|**IN1-**|Minus of the high-voltage bus (before contactors) 157 157 158 -=== X13 – header for external CAN and RS-485 interfaces === 156 +(% class="box warningmessage" %) 157 +((( 158 +The connected voltage must not exceed 1000V. 159 +))) 159 159 160 - ReceptacleHousing: Molex430250600.Terminals: Molex43030161 +=== X13 – header for high-voltage bus after contactors (plus) === 161 161 162 - [[image:https://docs.movicomelectric.com/bin/download/Battery%20management%20systems/BMS%20Main%202.1/2.%20Installation%20and%20connection/WebHome/1731517180930-597.png?width=113&height=81&rev=1.1||alt="1731517180930-597.png" height="81" width="113"]]163 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 163 163 165 +[[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] 166 + 164 164 |**Pin**|**Name**|**Description** 165 -|**1**|**EXT_RS485_A**|RS-485 line A for communication with external equipment 166 -|**2**|**CAN_H**|CAN H line for communication with external equipment 167 -|**3**|**+5V_CAN**|Supply voltage 5V for external devices, max 200 mA 168 -|**4**|**EXT_RS485_B**|RS-485 line B for communication with external equipment 169 -|**5**|**CAN_L**|CAN L line for communication with external equipment 170 -|**6**|**GND_CAN**|Ground 168 +|**1**|**IN2+**|Plus of the high-voltage bus (after contactors) 169 +|**2**|**IN2+**|Plus of the high-voltage bus (after contactors) 171 171 171 +(% class="box warningmessage" %) 172 +((( 173 +The connected voltage must not exceed 1000V. 174 +))) 175 + 172 172 === X14 – header for high-voltage bus after contactors (minus) === 173 173 174 174 Receptacle Housing: Molex 436450200. Terminals: Molex 43030