Changes for page 2. Installation and connection
Last modified by Admin on 2026/04/02 13:49
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -138,66 +138,60 @@ 138 138 [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 139 139 140 140 |**Pin**|**Name**|**Description** 141 -|**1**|** RS_LOGIC_A**|RS-485 line A for communication with BMS Logic142 -|**2**|** RS_LOGIC_B**|RS-485 line B for communication with BMS Logic143 -|**3**|** +5V**|Supply voltage for BMS Logic141 +|**1**|**LOGIC_A**|RS-485 line A for communication with BMS Logic 142 +|**2**|**LOGIC_B**|RS-485 line B for communication with BMS Logic 143 +|**3**|**LOGIC_5V**|Supply voltage for BMS Logic 144 144 |**4**|**GND**|Ground 145 145 146 -=== X12 – header for internalCAN interface ===146 +=== X12 – header for CAN2 interface === 147 147 148 148 Receptacle Housing: Molex 430250400. Terminals: Molex 43030 149 149 150 -[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 150 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]By defaul 151 151 152 152 |**Pin**|**Name**|**Description** 153 -|**1**|**CAN_ INT_H**|RS-485 line A for communication with BMS Logic154 -|**2**|**CAN_ INT_L**|RS-485lineBfor communication withBMSLogic155 -|**3**|** +5V**|Supply voltage for BMS Logic153 +|**1**|**CAN2_H**|RS-485 line A for communication with BMS Logic 154 +|**2**|**CAN2_L**|CAN L line for communication with external equipment 155 +|**3**|**–**|– 156 156 |**4**|**GND**|Ground 157 157 158 -=== X13 – header for externalCAN and RS-485 interfaces ===158 +=== X13 – header for CAN1 and RS-485 interfaces === 159 159 160 160 Receptacle Housing: Molex 430250600. Terminals: Molex 43030 161 161 162 -[[image:https://docs.movicomelectric.com/bin/download/Battery%20management%20systems/BMS%20Main%202.1/2.%20Installation%20and%20connection/WebHome/1731517180930-597.png?width=113&height=81&rev=1.1||alt="1731517180930-597.png" height="81" width="113"]] 162 +[[image:https://docs.movicomelectric.com/bin/download/Battery%20management%20systems/BMS%20Main%202.1/2.%20Installation%20and%20connection/WebHome/1731517180930-597.png?width=113&height=81&rev=1.1||alt="1731517180930-597.png" data-xwiki-image-style-alignment="center" height="81" width="113"]] 163 163 164 164 |**Pin**|**Name**|**Description** 165 -|**1**|** EXT_RS485_A**|RS-485 line A for communication with external equipment166 -|**2**|**CAN_H**|CAN H line for communication with external equipment 167 -|**3**|**+5V _CAN**|Supply voltage 5V for external devices, max 200 mA168 -|**4**|** EXT_RS485_B**|RS-485 line B for communication with external equipment169 -|**5**|**CAN_L**|CAN L line for communication with external equipment 170 -|**6**|**GND _CAN**|Ground165 +|**1**|**RS485_1_A**|RS-485 line A for communication with external equipment 166 +|**2**|**CAN1_H**|CAN H line for communication with external equipment 167 +|**3**|**+5V**|Supply voltage 5V for external devices, max 200 mA 168 +|**4**|**RS485_1_B**|RS-485 line B for communication with external equipment 169 +|**5**|**CAN1_L**|CAN L line for communication with external equipment 170 +|**6**|**GND**|Ground 171 171 172 -=== X14–header for high-voltage busaftercontactors(minus)===172 +=== J1 – jumper for switching internal CAN bus terminal resistor === 173 173 174 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030 175 175 176 -[[image:17333168 43397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]]175 +[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN2_H **and **CAN2_L **lines, install a jumper. The jumper is installed according to the table: 177 177 178 178 |**Pin**|**Name**|**Description** 179 -|**1**|** IN2-**|Minus of thehigh-voltagebus(aftercontactors)180 -|**2**|** IN2-**|Minus of thehigh-voltagebus(aftercontactors)178 +|**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN1 bus is connected 179 +|**2-3**|**-**|The 120 Ohm terminal resistor of the CAN1 bus is disconnected 181 181 182 -(% class="box warningmessage" %) 183 -((( 184 -The connected voltage must not exceed 1000V. 185 -))) 181 +=== J2 – jumper for switching RS-485 bus terminal resistor === 186 186 187 -=== J1 – jumper for switching RS-485-1 bus terminal resistor === 188 - 189 189 [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]] 190 190 191 -To connect a terminal resistor between the **RS485_1_A** and**RS485_1_B**lines, install a jumper. The jumper is installed according to the table:185 +To connect a terminal resistor between the **RS485_1_A **and **RS485_1_B **lines, install a jumper. The jumper is installed according to the table: 192 192 193 193 |**Pin**|**Name**|**Description** 194 194 |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the RS-485-1 bus is connected 195 195 |**2-3**|**-**|The 120 Ohm terminal resistor of the RS-485-1 bus is disconnected 196 196 197 -=== J 2– jumper for switching CAN1bus terminal resistor ===191 +=== J3 – jumper for switching external CAN bus terminal resistor === 198 198 199 199 200 -[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN1_H** and **CAN1_L**lines, install a jumper. The jumper is installed according to the table:194 +[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN1_H **and **CAN1_L **lines, install a jumper. The jumper is installed according to the table: 201 201 202 202 |**Pin**|**Name**|**Description** 203 203 |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN1 bus is connected