Changes for page 2. Installation and connection
Last modified by Admin on 2026/04/02 13:49
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -143,7 +143,7 @@ 143 143 |**3**|**+5V**|Supply voltage for BMS Logic 144 144 |**4**|**GND**|Ground 145 145 146 -=== X12 – header for internal CAN interface === 146 +=== X12 – header for internal CAN2 interface === 147 147 148 148 Receptacle Housing: Molex 430250400. Terminals: Molex 43030 149 149 ... ... @@ -151,41 +151,26 @@ 151 151 152 152 |**Pin**|**Name**|**Description** 153 153 |**1**|**CAN_INT_H**|RS-485 line A for communication with BMS Logic 154 -|**2**|**CAN_INT_L**| RS-485lineBfor communication withBMSLogic155 -|**3**|** +5V**|Supply voltage for BMS Logic154 +|**2**|**CAN_INT_L**|CAN L line for communication with external equipment 155 +|**3**|**–**|– 156 156 |**4**|**GND**|Ground 157 157 158 -=== X13 – header for externalCAN and RS-485 interfaces ===158 +=== X13 – header for CAN1 and RS-485 interfaces === 159 159 160 160 Receptacle Housing: Molex 430250600. Terminals: Molex 43030 161 161 162 -[[image:https://docs.movicomelectric.com/bin/download/Battery%20management%20systems/BMS%20Main%202.1/2.%20Installation%20and%20connection/WebHome/1731517180930-597.png?width=113&height=81&rev=1.1||alt="1731517180930-597.png" height="81" width="113"]] 162 +[[image:https://docs.movicomelectric.com/bin/download/Battery%20management%20systems/BMS%20Main%202.1/2.%20Installation%20and%20connection/WebHome/1731517180930-597.png?width=113&height=81&rev=1.1||alt="1731517180930-597.png" data-xwiki-image-style-alignment="center" height="81" width="113"]] 163 163 164 164 |**Pin**|**Name**|**Description** 165 -|**1**|**EXT_ RS485_A**|RS-485 line A for communication with external equipment166 -|**2**|**CAN_H**|CAN H line for communication with external equipment 167 -|**3**|**+5V _CAN**|Supply voltage 5V for external devices, max 200 mA168 -|**4**|**EXT_ RS485_B**|RS-485 line B for communication with external equipment169 -|**5**|**CAN_L**|CAN L line for communication with external equipment 170 -|**6**|**GND _CAN**|Ground165 +|**1**|**RS_EXT_A**|RS-485 line A for communication with external equipment 166 +|**2**|**CAN_EXT_H**|CAN H line for communication with external equipment 167 +|**3**|**+5V**|Supply voltage 5V for external devices, max 200 mA 168 +|**4**|**RS_EXT_B**|RS-485 line B for communication with external equipment 169 +|**5**|**CAN_EXT_L**|CAN L line for communication with external equipment 170 +|**6**|**GND**|Ground 171 171 172 -=== X14–header for high-voltagebusaftercontactors(minus)===172 +=== J1 – jumper for switching RS-485 bus terminal resistor === 173 173 174 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030 175 - 176 -[[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 177 - 178 -|**Pin**|**Name**|**Description** 179 -|**1**|**IN2-**|Minus of the high-voltage bus (after contactors) 180 -|**2**|**IN2-**|Minus of the high-voltage bus (after contactors) 181 - 182 -(% class="box warningmessage" %) 183 -((( 184 -The connected voltage must not exceed 1000V. 185 -))) 186 - 187 -=== J1 – jumper for switching RS-485-1 bus terminal resistor === 188 - 189 189 [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]] 190 190 191 191 To connect a terminal resistor between the **RS485_1_A** and **RS485_1_B** lines, install a jumper. The jumper is installed according to the table: