... ... @@ -151,8 +151,8 @@
151 151  
152 152  |**Pin**|**Name**|**Description**
153 153  |**1**|**CAN_INT_H**|RS-485 line A for communication with BMS Logic
154 -|**2**|**CAN_INT_L**|RS-485 line B for communication with BMS Logic
155 -|**3**|**+5V**|Supply voltage for BMS Logic
154 +|**2**|**CAN_INT_L**|CAN L line for communication with external equipment
155 +|**3**|****|
156 156  |**4**|**GND**|Ground
157 157  
158 158  === X13 – header for external CAN and RS-485 interfaces ===
... ... @@ -159,33 +159,18 @@
159 159  
160 160  Receptacle Housing: Molex 430250600. Terminals: Molex 43030
161 161  
162 -[[image:https://docs.movicomelectric.com/bin/download/Battery%20management%20systems/BMS%20Main%202.1/2.%20Installation%20and%20connection/WebHome/1731517180930-597.png?width=113&height=81&rev=1.1||alt="1731517180930-597.png" height="81" width="113"]]
162 +[[image:https://docs.movicomelectric.com/bin/download/Battery%20management%20systems/BMS%20Main%202.1/2.%20Installation%20and%20connection/WebHome/1731517180930-597.png?width=113&height=81&rev=1.1||alt="1731517180930-597.png" data-xwiki-image-style-alignment="center" height="81" width="113"]]
163 163  
164 164  |**Pin**|**Name**|**Description**
165 -|**1**|**EXT_RS485_A**|RS-485 line A for communication with external equipment
166 -|**2**|**CAN_H**|CAN H line for communication with external equipment
167 -|**3**|**+5V_CAN**|Supply voltage 5V for external devices, max 200 mA
168 -|**4**|**EXT_RS485_B**|RS-485 line B for communication with external equipment
169 -|**5**|**CAN_L**|CAN L line for communication with external equipment
170 -|**6**|**GND_CAN**|Ground
165 +|**1**|**RS_EXT_A**|RS-485 line A for communication with external equipment
166 +|**2**|**CAN_EXT_H**|CAN H line for communication with external equipment
167 +|**3**|**+5V**|Supply voltage 5V for external devices, max 200 mA
168 +|**4**|**RS_EXT_B**|RS-485 line B for communication with external equipment
169 +|**5**|**CAN_EXT_L**|CAN L line for communication with external equipment
170 +|**6**|**GND**|Ground
171 171  
172 -=== X14header for high-voltage bus after contactors (minus) ===
172 +=== J1 – jumper for switching RS-485 bus terminal resistor ===
173 173  
174 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030
175 -
176 -[[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]]
177 -
178 -|**Pin**|**Name**|**Description**
179 -|**1**|**IN2-**|Minus of the high-voltage bus (after contactors)
180 -|**2**|**IN2-**|Minus of the high-voltage bus (after contactors)
181 -
182 -(% class="box warningmessage" %)
183 -(((
184 -The connected voltage must not exceed 1000V.
185 -)))
186 -
187 -=== J1 – jumper for switching RS-485-1 bus terminal resistor ===
188 -
189 189  [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]
190 190  
191 191  To connect a terminal resistor between the **RS485_1_A** and **RS485_1_B** lines, install a jumper. The jumper is installed according to the table: