Changes for page 2. Installation and connection
Last modified by Admin on 2026/04/02 13:49
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - drafts.BMS Main 2R.WebHome1 +Battery management systems.BMS Main 2R.WebHome - Content
-
... ... @@ -138,139 +138,100 @@ 138 138 [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 139 139 140 140 |**Pin**|**Name**|**Description** 141 -|**1**|** RS485_A**|RS-485 line A for communication with BMS Logic142 -|**2**|** RS485_B**|RS-485 line B for communication with BMS Logic143 -|**3**|** +5V**|Supply voltage for BMS Logic141 +|**1**|**LOGIC_A**|RS-485 line A for communication with BMS Logic 142 +|**2**|**LOGIC_B**|RS-485 line B for communication with BMS Logic 143 +|**3**|**LOGIC_5V**|Supply voltage for BMS Logic 144 144 |**4**|**GND**|Ground 145 145 146 -=== X12 – header for high-voltagebus before contactors(minus)===146 +=== X12 – header for CAN2 interface === 147 147 148 -Receptacle Housing: Molex 43 6450200. Terminals: Molex 43030148 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 149 149 150 -[[image:173 3316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]]150 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 151 151 152 152 |**Pin**|**Name**|**Description** 153 -|**1**|**IN1-**|Minus of the high-voltage bus (before contactors) 154 -|**2**|**IN1-**|Minus of the high-voltage bus (before contactors) 153 +|**1**|**CAN2_H**|CAN2 H line for communication with internal equipment 154 +|**2**|**CAN2_L**|CAN2 L line for communication with internal equipment 155 +|**3**|**–**|– 156 +|**4**|**GND**|Ground 155 155 156 -(% class="box warningmessage" %) 157 -((( 158 -The connected voltage must not exceed 1000V. 159 -))) 158 +=== X13 – header for CAN1 and RS-485 interfaces === 160 160 161 - === X13 – headerfor high-voltagebusaftercontactors (plus)===160 +Receptacle Housing: Molex 430250600. Terminals: Molex 43030 162 162 163 - ReceptacleHousing: Molex 436450200. Terminals: Molex 43030162 +[[image:https://docs.movicomelectric.com/bin/download/Battery%20management%20systems/BMS%20Main%202.1/2.%20Installation%20and%20connection/WebHome/1731517180930-597.png?width=113&height=81&rev=1.1||alt="1731517180930-597.png" data-xwiki-image-style-alignment="center" height="81" width="113"]] 164 164 165 -[[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] 166 - 167 167 |**Pin**|**Name**|**Description** 168 -|**1**|**IN2+**|Plus of the high-voltage bus (after contactors) 169 -|**2**|**IN2+**|Plus of the high-voltage bus (after contactors) 165 +|**1**|**RS485_1_A**|RS-485-1 line A for communication with external equipment 166 +|**2**|**CAN1_H**|CAN1 H line for communication with external equipment 167 +|**3**|**+5V**|Supply voltage 5V for external devices, max 200 mA 168 +|**4**|**RS485_1_B**|RS-485-1 line B for communication with external equipment 169 +|**5**|**CAN1_L**|CAN1 L line for communication with external equipment 170 +|**6**|**GND**|Ground 170 170 171 -(% class="box warningmessage" %) 172 -((( 173 -The connected voltage must not exceed 1000V. 174 -))) 172 +=== J1 – jumper for switching CAN2 bus terminal resistor === 175 175 176 -=== X14 – header for high-voltage bus after contactors (minus) === 177 177 178 - ReceptacleHousing:Molex436450200. Terminals: Molex43030175 +[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN2_H **and **CAN2_L **lines, install a jumper. The jumper is installed according to the table: 179 179 180 -[[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 181 - 182 182 |**Pin**|**Name**|**Description** 183 -|**1**|** IN2-**|Minus of thehigh-voltagebus(aftercontactors)184 -|**2**|** IN2-**|Minus of thehigh-voltagebus(aftercontactors)178 +|**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN1 bus is connected 179 +|**2-3**|**-**|The 120 Ohm terminal resistor of the CAN1 bus is disconnected 185 185 186 -(% class="box warningmessage" %) 187 -((( 188 -The connected voltage must not exceed 1000V. 189 -))) 181 +=== J2 – jumper for switching RS-485-1 bus terminal resistor === 190 190 191 -=== J1 – jumper for switching RS-485-1 bus terminal resistor === 192 - 193 193 [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]] 194 194 195 -To connect a terminal resistor between the **RS485_1_A** and**RS485_1_B**lines, install a jumper. The jumper is installed according to the table:185 +To connect a terminal resistor between the **RS485_1_A **and **RS485_1_B **lines, install a jumper. The jumper is installed according to the table: 196 196 197 197 |**Pin**|**Name**|**Description** 198 198 |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the RS-485-1 bus is connected 199 199 |**2-3**|**-**|The 120 Ohm terminal resistor of the RS-485-1 bus is disconnected 200 200 201 -=== J 2– jumper for switching CAN1 bus terminal resistor ===191 +=== J3 – jumper for switching CAN1 bus terminal resistor === 202 202 203 203 204 -[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN1_H** and **CAN1_L**lines, install a jumper. The jumper is installed according to the table:194 +[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN1_H **and **CAN1_L **lines, install a jumper. The jumper is installed according to the table: 205 205 206 206 |**Pin**|**Name**|**Description** 207 207 |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN1 bus is connected 208 208 |**2-3**|**-**|The 120 Ohm terminal resistor of the CAN1 bus is disconnected 209 209 210 -=== J3 – jumper for switching CAN2 bus terminal resistor === 211 - 212 - 213 -[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN2_H** and **CAN2_L** lines, install a jumper. The jumper is installed according to the table: 214 - 215 -|**Pin**|**Name**|**Description** 216 -|**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN2 bus is connected 217 -|**2-3**|**-**|The 120 Ohm terminal resistor of the CAN2 bus is disconnected 218 - 219 -=== J5, J6 – jumpers for emergency opening of contactors when removing discrete input signals DIN7, DIN8 === 220 - 221 -The BMS Main 2R device implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed. 222 - 223 223 == Indicators == 224 224 225 -=== DS 1–LED indicatingdevice power ===202 +=== DS2 – operation indicator === 226 226 227 227 |**State**|**Description** 228 -|** Lightsupgreen**|Devicepower(+5V)ispresent229 -|** Doesn’t light up**|No devicepower205 +|**Blinking green**|The BMS firmware is running 206 +|**Off**|The BMS firmware is not running 230 230 231 -=== DS 2–LED indicatingdevice work===208 +=== DS3 – communication indicator === 232 232 233 233 |**State**|**Description** 234 -|**Blinking green**|Executingthe batterymanagementprogram235 -|** No blinking**|Programexecutionerror211 +|**Blinking yellow (2Hz)**|Initializing communication with BMS Logic boards 212 +|**Blinking yellow (25Hz)**|Communication with BMS Logic is established 236 236 237 -=== DS 3–LEDindicating interactionwith child devices===214 +=== DS4 – error indicator === 238 238 239 -(% style="width:447px" %) 240 -|**State**|(% style="width:166px" %)**Description (Main 3)**|(% style="width:168px" %)**Description (Main 3X)** 241 -|**Blinking yellow**|(% style="width:166px" %)The device interacts with BMS Logic devices|(% style="width:168px" %)The device interacts with BMS Main 3 devices 242 -|**No blinking**|(% style="width:166px" %)-|(% style="width:168px" %)- 243 - 244 -=== DS4 – LED indicating loss of connection with child devices === 245 - 246 -(% style="width:601px" %) 247 -|**State**|(% style="width:220px" %)**Description (Main 3)**|(% style="width:218px" %)**Description (Main 3X)** 248 -|**Blinking/lights up red**|(% style="width:220px" %)Communication with one or more BMS Logic devices is lost|(% style="width:218px" %)Communication with one or more BMS Main 3 devices is lost 249 -|**No blinking**|(% style="width:220px" %)Communication with BMS Logic devices is stable|(% style="width:218px" %)Communication with BMS Main 3 devices is stable 250 - 251 -=== DS5-DS10 – LEDs indicating contactor switches 1-6 === 252 - 253 253 |**State**|**Description** 254 -|**Lights up green**|The switch supplies voltage to the contactor winding 255 -|**Doesn’t light up**|The switch doesn’t supply voltage to the contactor winding 217 +|**Blinking red**|Errors in communication with BMS Logic 256 256 257 -=== DS11 – LED indicating the presence of power supplyforcontactors===219 +=== DS1.1-DS1.4 – relay 1-4 indicator === 258 258 259 259 |**State**|**Description** 260 -|**Lights upgreen**|Power supplyfor contactor switches (9-32V)ispresent261 -|** Doesn’t light up**|Power supplyfor contactor switches (9-32V)isnotpresent222 +|**Lights green**|Relay #1-#4 is closed 223 +|**Off**|Relay #1-#4 is opened 262 262 263 263 == Connection procedure == 264 264 265 265 All operations to connect the device must be carried out with the supply voltage removed. 266 266 267 -* Connect the power contactors to header X2. 268 -* Connect one or more current sensors, as well as external temperature sensors (if necessary) to header X5. 269 -* Connect BMS Logic devices to header X9. 270 -* Connect digital inputs and outputs (if necessary) to header X3. 271 -* Connect the high voltage bus (if necessary) to headers X11-X14. 272 -* Connect the high-voltage network integrity circuit (if necessary) to header X4. 273 -* Connect external devices (if necessary) to header X6. 274 -* Connect other devices (BMS Indication, BMS Display, if necessary) to header X7. 275 -* If the BMS Main 2R is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3. 276 -* Connect an external power supply to header X1. The device will start when there is a 9-32V power supply and one of the KEYRUN or CHARGE_ON signals with a voltage of more than 8.5V is supplied. 229 +* Connect the power contactors to headers X4-X7. 230 +* Connect one or more current sensors to headers X8 and X9. 231 +* Connect external temperature sensors (if necessary) to header X10. 232 +* Connect BMS Logic devices to header X11. 233 +* Connect digital inputs and outputs (if necessary) to header X1. 234 +* Connect external devices (if necessary) to header X13. 235 +* Connect other devices (BMS Indication, BMS Display, if necessary) to header X12. 236 +* If the BMS Main 2R is the last device on the CAN2, RS-485-1 or CAN1 bus, install jumpers J1-J3. 237 +* Connect an external power supply to header X3. The device will start when there is a 9-32V power supply.