138 138  [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]
139 139  
140 140  |**Pin**|**Name**|**Description**
141 -|**1**|**RS485_A**|RS-485 line A for communication with BMS Logic
142 -|**2**|**RS485_B**|RS-485 line B for communication with BMS Logic
141 +|**1**|**RS_LOGIC_A**|RS-485 line A for communication with BMS Logic
142 +|**2**|**RS_LOGIC_B**|RS-485 line B for communication with BMS Logic
143 143  |**3**|**+5V**|Supply voltage for BMS Logic
144 144  |**4**|**GND**|Ground
145 145  
146 -=== X12 – header for high-voltage bus before contactors (minus) ===
146 +=== X12 – header for internal CAN2 interface ===
147 147  
148 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030
148 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030
149 149  
150 -[[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]]
150 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]
151 151  
152 152  |**Pin**|**Name**|**Description**
153 -|**1**|**IN1-**|Minus of the high-voltage bus (before contactors)
154 -|**2**|**IN1-**|Minus of the high-voltage bus (before contactors)
153 +|**1**|**CAN_INT_H**|RS-485 line A for communication with BMS Logic
154 +|**2**|**CAN_INT_L**|CAN L line for communication with external equipment
155 +|**3**|**–**|–
156 +|**4**|**GND**|Ground
155 155  
156 -(% class="box warningmessage" %)
157 -(((
158 -The connected voltage must not exceed 1000V.
159 -)))
158 +=== X13 – header for CAN1 and RS-485 interfaces ===
160 160  
161 -=== X13 – header for high-voltage bus after contactors (plus) ===
160 +Receptacle Housing: Molex 430250600. Terminals: Molex 43030
162 162  
163 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030
162 +[[image:https://docs.movicomelectric.com/bin/download/Battery%20management%20systems/BMS%20Main%202.1/2.%20Installation%20and%20connection/WebHome/1731517180930-597.png?width=113&height=81&rev=1.1||alt="1731517180930-597.png" data-xwiki-image-style-alignment="center" height="81" width="113"]]
164 164  
165 -[[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]]
166 -
167 167  |**Pin**|**Name**|**Description**
168 -|**1**|**IN2+**|Plus of the high-voltage bus (after contactors)
169 -|**2**|**IN2+**|Plus of the high-voltage bus (after contactors)
165 +|**1**|**RS_EXT_A**|RS-485 line A for communication with external equipment
166 +|**2**|**CAN_EXT_H**|CAN H line for communication with external equipment
167 +|**3**|**+5V**|Supply voltage 5V for external devices, max 200 mA
168 +|**4**|**RS_EXT_B**|RS-485 line B for communication with external equipment
169 +|**5**|**CAN_EXT_L**|CAN L line for communication with external equipment
170 +|**6**|**GND**|Ground
170 170  
171 -(% class="box warningmessage" %)
172 -(((
173 -The connected voltage must not exceed 1000V.
174 -)))
172 +=== J1 – jumper for switching internal CAN bus terminal resistor ===
175 175  
176 -=== X14 – header for high-voltage bus after contactors (minus) ===
177 177  
178 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030
175 +[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN_INT_H **and **CAN_INT_L **lines, install a jumper. The jumper is installed according to the table:
179 179  
180 -[[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]]
181 -
182 182  |**Pin**|**Name**|**Description**
183 -|**1**|**IN2-**|Minus of the high-voltage bus (after contactors)
184 -|**2**|**IN2-**|Minus of the high-voltage bus (after contactors)
178 +|**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN1 bus is connected
179 +|**2-3**|**-**|The 120 Ohm terminal resistor of the CAN1 bus is disconnected
185 185  
186 -(% class="box warningmessage" %)
187 -(((
188 -The connected voltage must not exceed 1000V.
189 -)))
181 +=== J2 – jumper for switching RS-485 bus terminal resistor ===
190 190  
191 -=== J1 – jumper for switching RS-485-1 bus terminal resistor ===
192 -
193 193  [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]
194 194  
195 -To connect a terminal resistor between the **RS485_1_A** and **RS485_1_B** lines, install a jumper. The jumper is installed according to the table:
185 +To connect a terminal resistor between the **RS_EXT_A **and **RS_EXT_B **lines, install a jumper. The jumper is installed according to the table:
196 196  
197 197  |**Pin**|**Name**|**Description**
198 198  |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the RS-485-1 bus is connected
199 199  |**2-3**|**-**|The 120 Ohm terminal resistor of the RS-485-1 bus is disconnected
200 200  
201 -=== J2 – jumper for switching CAN1 bus terminal resistor ===
191 +=== J3 – jumper for switching external CAN bus terminal resistor ===
202 202  
203 203  
204 -[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN1_H** and **CAN1_L** lines, install a jumper. The jumper is installed according to the table:
194 +[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN_EXT_H** and **CAN_EXT_L** lines, install a jumper. The jumper is installed according to the table: