Changes for page 2. Installation and connection
Last modified by Admin on 2026/04/02 13:49
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -138,58 +138,39 @@ 138 138 [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 139 139 140 140 |**Pin**|**Name**|**Description** 141 -|**1**|**RS 485_A**|RS-485 line A for communication with BMS Logic142 -|**2**|**RS 485_B**|RS-485 line B for communication with BMS Logic141 +|**1**|**RS_LOGIC_A**|RS-485 line A for communication with BMS Logic 142 +|**2**|**RS_LOGIC_B**|RS-485 line B for communication with BMS Logic 143 143 |**3**|**+5V**|Supply voltage for BMS Logic 144 144 |**4**|**GND**|Ground 145 145 146 -=== X12 – header for high-voltagebus beforecontactors(minus)===146 +=== X12 – header for internal CAN2 interface === 147 147 148 -Receptacle Housing: Molex 43 6450200. Terminals: Molex 43030148 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 149 149 150 -[[image:173 3316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]]150 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 151 151 152 152 |**Pin**|**Name**|**Description** 153 -|**1**|**IN1-**|Minus of the high-voltage bus (before contactors) 154 -|**2**|**IN1-**|Minus of the high-voltage bus (before contactors) 153 +|**1**|**CAN_INT_H**|RS-485 line A for communication with BMS Logic 154 +|**2**|**CAN_INT_L**|CAN L line for communication with external equipment 155 +|**3**|**–**|– 156 +|**4**|**GND**|Ground 155 155 156 -(% class="box warningmessage" %) 157 -((( 158 -The connected voltage must not exceed 1000V. 159 -))) 158 +=== X13 – header for CAN1 and RS-485 interfaces === 160 160 161 - === X13 – headerfor high-voltagebusaftercontactors (plus)===160 +Receptacle Housing: Molex 430250600. Terminals: Molex 43030 162 162 163 - ReceptacleHousing: Molex 436450200. Terminals: Molex 43030162 +[[image:https://docs.movicomelectric.com/bin/download/Battery%20management%20systems/BMS%20Main%202.1/2.%20Installation%20and%20connection/WebHome/1731517180930-597.png?width=113&height=81&rev=1.1||alt="1731517180930-597.png" data-xwiki-image-style-alignment="center" height="81" width="113"]] 164 164 165 -[[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] 166 - 167 167 |**Pin**|**Name**|**Description** 168 -|**1**|**IN2+**|Plus of the high-voltage bus (after contactors) 169 -|**2**|**IN2+**|Plus of the high-voltage bus (after contactors) 165 +|**1**|**RS_EXT_A**|RS-485 line A for communication with external equipment 166 +|**2**|**CAN_EXT_H**|CAN H line for communication with external equipment 167 +|**3**|**+5V**|Supply voltage 5V for external devices, max 200 mA 168 +|**4**|**RS_EXT_B**|RS-485 line B for communication with external equipment 169 +|**5**|**CAN_EXT_L**|CAN L line for communication with external equipment 170 +|**6**|**GND**|Ground 170 170 171 -(% class="box warningmessage" %) 172 -((( 173 -The connected voltage must not exceed 1000V. 174 -))) 172 +=== J1 – jumper for switching RS-485 bus terminal resistor === 175 175 176 -=== X14 – header for high-voltage bus after contactors (minus) === 177 - 178 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030 179 - 180 -[[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 181 - 182 -|**Pin**|**Name**|**Description** 183 -|**1**|**IN2-**|Minus of the high-voltage bus (after contactors) 184 -|**2**|**IN2-**|Minus of the high-voltage bus (after contactors) 185 - 186 -(% class="box warningmessage" %) 187 -((( 188 -The connected voltage must not exceed 1000V. 189 -))) 190 - 191 -=== J1 – jumper for switching RS-485-1 bus terminal resistor === 192 - 193 193 [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]] 194 194 195 195 To connect a terminal resistor between the **RS485_1_A** and **RS485_1_B** lines, install a jumper. The jumper is installed according to the table: