Last modified by Admin on 2026/04/02 13:49

From version 88.2
edited by Admin
on 2026/03/25 16:42
Change comment: There is no comment for this version
To version 89.1
edited by Admin
on 2026/03/25 16:43
Change comment: Uploaded new attachment "1731517180930-597.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -138,41 +138,37 @@
138 138  [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]
139 139  
140 140  |**Pin**|**Name**|**Description**
141 -|**1**|**RS485_A**|RS-485 line A for communication with BMS Logic
142 -|**2**|**RS485_B**|RS-485 line B for communication with BMS Logic
141 +|**1**|**RS_LOGIC_A**|RS-485 line A for communication with BMS Logic
142 +|**2**|**RS_LOGIC_B**|RS-485 line B for communication with BMS Logic
143 143  |**3**|**+5V**|Supply voltage for BMS Logic
144 144  |**4**|**GND**|Ground
145 145  
146 -=== X12 – header for high-voltage bus before contactors (minus) ===
146 +=== X12 – header for internal CAN interface ===
147 147  
148 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030
148 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030
149 149  
150 -[[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]]
150 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]
151 151  
152 152  |**Pin**|**Name**|**Description**
153 -|**1**|**IN1-**|Minus of the high-voltage bus (before contactors)
154 -|**2**|**IN1-**|Minus of the high-voltage bus (before contactors)
153 +|**1**|**CAN_INT_H**|RS-485 line A for communication with BMS Logic
154 +|**2**|**CAN_INT_L**|RS-485 line B for communication with BMS Logic
155 +|**3**|**+5V**|Supply voltage for BMS Logic
156 +|**4**|**GND**|Ground
155 155  
156 -(% class="box warningmessage" %)
157 -(((
158 -The connected voltage must not exceed 1000V.
159 -)))
158 +=== X13 – header for external CAN and RS-485 interfaces ===
160 160  
161 -=== X13 – header for high-voltage bus after contactors (plus) ===
160 +Receptacle Housing: Molex 430250600. Terminals: Molex 43030
162 162  
163 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030
162 +[[image:https://docs.movicomelectric.com/bin/download/Battery%20management%20systems/BMS%20Main%202.1/2.%20Installation%20and%20connection/WebHome/1731517180930-597.png?width=113&height=81&rev=1.1||alt="1731517180930-597.png" height="81" width="113"]]
164 164  
165 -[[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]]
166 -
167 167  |**Pin**|**Name**|**Description**
168 -|**1**|**IN2+**|Plus of the high-voltage bus (after contactors)
169 -|**2**|**IN2+**|Plus of the high-voltage bus (after contactors)
165 +|**1**|**EXT_RS485_A**|RS-485 line A for communication with external equipment
166 +|**2**|**CAN_H**|CAN H line for communication with external equipment
167 +|**3**|**+5V_CAN**|Supply voltage 5V for external devices, max 200 mA
168 +|**4**|**EXT_RS485_B**|RS-485 line B for communication with external equipment
169 +|**5**|**CAN_L**|CAN L line for communication with external equipment
170 +|**6**|**GND_CAN**|Ground
170 170  
171 -(% class="box warningmessage" %)
172 -(((
173 -The connected voltage must not exceed 1000V.
174 -)))
175 -
176 176  === X14 – header for high-voltage bus after contactors (minus) ===
177 177  
178 178  Receptacle Housing: Molex 436450200. Terminals: Molex 43030