Last modified by Admin on 2026/04/02 13:49

From version 88.2
edited by Admin
on 2026/03/25 16:42
Change comment: There is no comment for this version
To version 88.1
edited by Admin
on 2026/03/25 16:41
Change comment: Uploaded new attachment "1732198890482-787.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -128,21 +128,24 @@
128 128  
129 129  |**Pin**|**Name**|**Description**
130 130  |**1, 2**|**GND**|Ground
131 -|**3**|**T_SENS1**|Temperature sensor 1 output
132 -|**4**|**T_SENS2**|Temperature sensor 2 output
131 +|**3**|**T_SENS1**|Ground
132 +|**4**|**T_SENS2**|Current sensor 2 output
133 133  
134 -=== X11 – (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)header for BMS Logic(%%) ===
134 +=== X11 – header for high-voltage bus before contactors (plus) ===
135 135  
136 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030
136 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030
137 137  
138 -[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]
138 +[[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]]
139 139  
140 140  |**Pin**|**Name**|**Description**
141 -|**1**|**RS485_A**|RS-485 line A for communication with BMS Logic
142 -|**2**|**RS485_B**|RS-485 line B for communication with BMS Logic
143 -|**3**|**+5V**|Supply voltage for BMS Logic
144 -|**4**|**GND**|Ground
141 +|**1**|**IN1+**|Plus of the high-voltage bus (before contactors)
142 +|**2**|**IN1+**|Plus of the high-voltage bus (before contactors)
145 145  
144 +(% class="box warningmessage" %)
145 +(((
146 +The connected voltage must not exceed 1000V.
147 +)))
148 +
146 146  === X12 – header for high-voltage bus before contactors (minus) ===
147 147  
148 148  Receptacle Housing: Molex 436450200. Terminals: Molex 43030