Changes for page 2. Installation and connection
Last modified by Admin on 2026/04/02 13:49
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -108,41 +108,46 @@ 108 108 |**3**|**CS1_OUT**|Current sensor 1 output 109 109 |**4**|**CS1_REF**|Current sensor 1 reference signal 110 110 111 -=== X9 – (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)header forcurrentsensor2(%%) ===111 +=== X9 – header for BMS Logic (RS-485-2) === 112 112 113 -Receptacle Housing: Molex430250400. Terminals:Molex43030113 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 114 114 115 -[[image:173 2198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]115 +[[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 116 116 117 117 |**Pin**|**Name**|**Description** 118 -|**1**|** +5V**|Supplyvoltage forthecurrentsensor5V,max50 mA119 -|**2**|**G ND**|Ground120 -|**3**|** CS2_OUT**|Current sensor 2 output121 -|**4**|**C S2_REF**|Currentsensor2 referencesignal118 +|**1**|**LOGIC_B**|RS-485 line B for communication with BMS Logic 119 +|**2**|**LOGIC_A**|RS-485 line A for communication with BMS Logic 120 +|**3**|**GND**|Ground 121 +|**4**|**LOGIC_5V**|BMS Logic power line (+5V, max 400mA) 122 122 123 -=== X10 – (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)header for temperature sensors(%%) === 123 +(% class="box infomessage" %) 124 +((( 125 +**Note:** 126 +RS-485-2 operates differently depending on used firmware: 124 124 125 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030 128 +* **BMS Main 3X:** RS-485-2 bus is reserved; 129 +* **BMS Main 3:** RS-485-2 bus is used to connect with BMS Logics in a battery pack. Connection diagram for BMS Logic devices: 126 126 127 -[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 131 +[[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="163" width="400"]] 132 +))) 128 128 129 -|**Pin**|**Name**|**Description** 130 -|**1, 2**|**GND**|Ground 131 -|**3**|**T_SENS1**|Temperature sensor 1 output 132 -|**4**|**T_SENS2**|Temperature sensor 2 output 134 +=== X10 – === 133 133 134 -=== X11 – (% style="color:inherit; font-family:inherit;font-size:max(18px,min(20px, 14.4444px + 0.462963vw))" %)headerforBMS Logic(%%) ===136 +=== X11 – header for high-voltage bus before contactors (plus) === 135 135 136 -Receptacle Housing: Molex 4302 50400. Terminals: Molex 43030138 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 137 137 138 -[[image:173 2198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]140 +[[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] 139 139 140 140 |**Pin**|**Name**|**Description** 141 -|**1**|**RS485_A**|RS-485 line A for communication with BMS Logic 142 -|**2**|**RS485_B**|RS-485 line B for communication with BMS Logic 143 -|**3**|**+5V**|Supply voltage for BMS Logic 144 -|**4**|**GND**|Ground 143 +|**1**|**IN1+**|Plus of the high-voltage bus (before contactors) 144 +|**2**|**IN1+**|Plus of the high-voltage bus (before contactors) 145 145 146 +(% class="box warningmessage" %) 147 +((( 148 +The connected voltage must not exceed 1000V. 149 +))) 150 + 146 146 === X12 – header for high-voltage bus before contactors (minus) === 147 147 148 148 Receptacle Housing: Molex 436450200. Terminals: Molex 43030