Changes for page 2. Installation and connection
Last modified by Admin on 2026/04/02 13:49
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -128,83 +128,70 @@ 128 128 129 129 |**Pin**|**Name**|**Description** 130 130 |**1, 2**|**GND**|Ground 131 -|**3**|**T_SENS1**| Ground132 -|**4**|**T_SENS2**| Currentsensor 2output131 +|**3**|**T_SENS1**|Temperature sensor 1 output 132 +|**4**|**T_SENS2**|Temperature sensor 2 output 133 133 134 -=== X11 – he ader for high-voltagebusbeforecontactors(plus) ===134 +=== X11 – (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)header for BMS Logic(%%) === 135 135 136 -Receptacle Housing: Molex 43 6450200. Terminals: Molex 43030136 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 137 137 138 -[[image:173 3316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]]138 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 139 139 140 140 |**Pin**|**Name**|**Description** 141 -|**1**|**IN1+**|Plus of the high-voltage bus (before contactors) 142 -|**2**|**IN1+**|Plus of the high-voltage bus (before contactors) 141 +|**1**|**RS_LOGIC_A**|RS-485 line A for communication with BMS Logic 142 +|**2**|**RS_LOGIC_B**|RS-485 line B for communication with BMS Logic 143 +|**3**|**+5V**|Supply voltage for BMS Logic 144 +|**4**|**GND**|Ground 143 143 144 -(% class="box warningmessage" %) 145 -((( 146 -The connected voltage must not exceed 1000V. 147 -))) 146 +=== X12 – header for internal CAN2 interface === 148 148 149 - === X12 – headerfor high-voltagebusbefore contactors (minus)===148 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 150 150 151 - Receptacle Housing: Molex 436450200.Terminals: Molex43030150 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 152 152 153 -[[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 154 - 155 155 |**Pin**|**Name**|**Description** 156 -|**1**|**IN1-**|Minus of the high-voltage bus (before contactors) 157 -|**2**|**IN1-**|Minus of the high-voltage bus (before contactors) 153 +|**1**|**CAN_INT_H**|RS-485 line A for communication with BMS Logic 154 +|**2**|**CAN_INT_L**|CAN L line for communication with external equipment 155 +|**3**|**–**|– 156 +|**4**|**GND**|Ground 158 158 159 -(% class="box warningmessage" %) 160 -((( 161 -The connected voltage must not exceed 1000V. 162 -))) 158 +=== X13 – header for CAN1 and RS-485 interfaces === 163 163 164 - === X13 – headerfor high-voltagebusaftercontactors (plus)===160 +Receptacle Housing: Molex 430250600. Terminals: Molex 43030 165 165 166 - ReceptacleHousing: Molex 436450200. Terminals: Molex 43030162 +[[image:https://docs.movicomelectric.com/bin/download/Battery%20management%20systems/BMS%20Main%202.1/2.%20Installation%20and%20connection/WebHome/1731517180930-597.png?width=113&height=81&rev=1.1||alt="1731517180930-597.png" data-xwiki-image-style-alignment="center" height="81" width="113"]] 167 167 168 -[[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] 169 - 170 170 |**Pin**|**Name**|**Description** 171 -|**1**|**IN2+**|Plus of the high-voltage bus (after contactors) 172 -|**2**|**IN2+**|Plus of the high-voltage bus (after contactors) 165 +|**1**|**RS_EXT_A**|RS-485 line A for communication with external equipment 166 +|**2**|**CAN_EXT_H**|CAN H line for communication with external equipment 167 +|**3**|**+5V**|Supply voltage 5V for external devices, max 200 mA 168 +|**4**|**RS_EXT_B**|RS-485 line B for communication with external equipment 169 +|**5**|**CAN_EXT_L**|CAN L line for communication with external equipment 170 +|**6**|**GND**|Ground 173 173 174 -(% class="box warningmessage" %) 175 -((( 176 -The connected voltage must not exceed 1000V. 177 -))) 172 +=== J1 – jumper for switching internal CAN bus terminal resistor === 178 178 179 -=== X14 – header for high-voltage bus after contactors (minus) === 180 180 181 - ReceptacleHousing:Molex436450200. Terminals: Molex43030175 +[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN_INT_H **and **CAN_INT_L **lines, install a jumper. The jumper is installed according to the table: 182 182 183 -[[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 184 - 185 185 |**Pin**|**Name**|**Description** 186 -|**1**|** IN2-**|Minus of thehigh-voltagebus(aftercontactors)187 -|**2**|** IN2-**|Minus of thehigh-voltagebus(aftercontactors)178 +|**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN1 bus is connected 179 +|**2-3**|**-**|The 120 Ohm terminal resistor of the CAN1 bus is disconnected 188 188 189 -(% class="box warningmessage" %) 190 -((( 191 -The connected voltage must not exceed 1000V. 192 -))) 181 +=== J2 – jumper for switching RS-485 bus terminal resistor === 193 193 194 -=== J1 – jumper for switching RS-485-1 bus terminal resistor === 195 - 196 196 [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]] 197 197 198 -To connect a terminal resistor between the **RS 485_1_A**and**RS485_1_B**lines, install a jumper. The jumper is installed according to the table:185 +To connect a terminal resistor between the **RS_EXT_A **and **RS_EXT_B **lines, install a jumper. The jumper is installed according to the table: 199 199 200 200 |**Pin**|**Name**|**Description** 201 201 |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the RS-485-1 bus is connected 202 202 |**2-3**|**-**|The 120 Ohm terminal resistor of the RS-485-1 bus is disconnected 203 203 204 -=== J 2– jumper for switching CAN1bus terminal resistor ===191 +=== J3 – jumper for switching external CAN bus terminal resistor === 205 205 206 206 207 -[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN 1_H** and **CAN1_L**lines, install a jumper. The jumper is installed according to the table:194 +[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN_EXT_H** and **CAN_EXT_L** lines, install a jumper. The jumper is installed according to the table: 208 208 209 209 |**Pin**|**Name**|**Description** 210 210 |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN1 bus is connected