Changes for page 2. Installation and connection
Last modified by Admin on 2026/04/02 13:49
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -81,56 +81,173 @@ 81 81 82 82 83 83 84 -=== X4, X5, X6, X7 – headerofrelay 1, 2, 3 and 4===84 +=== X4, X5, X6, X7 – === 85 85 86 -Receptacle Housing: Molex39012020. Terminals:Molex555686 +Receptacle Housing: Hirose ZE05-24DS-HU/R. Terminals: Hirose ZE05-2022SCF 87 87 88 -[[image:17321 98827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]]88 +(% aria-label="1732121811285-182.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121811285-182.png||data-xwiki-image-style-alignment="center" height="94" width="531"]] 89 89 90 90 |**Pin**|**Name**|**Description** 91 -|**1**|**V+**|Switching voltage (up to 55V, max 3A) 92 -|**2**|**NO**|Normally open contact 91 +|**1–8, 12, 16–17, 21**|**DIO_GND**|Ground of input and output signals 92 +|**9**|**DIN1_SIGNAL**|Discrete input 1 “dry contact” 93 +|**10**|**DIN2_SIGNAL**|Discrete input 2 “dry contact” 94 +|**11**|**DIN3_SIGNAL**|Discrete input 3 “dry contact” 95 +|**13**|**DIN4_SIGNAL**|Discrete input 4 “dry contact” 96 +|**14**|**DIN5_SIGNAL**|Discrete input 5 “dry contact” 97 +|**15**|**DIN6_SIGNAL**|Discrete input 6 “dry contact” 98 +|**18**|**DIN7_VIN**|Discrete input 7 (signal detection with voltage 9-32V) 99 +|**19**|**DIN8_VIN**|Discrete input 8 (signal detection with voltage 9-32V) 100 +|**20**|**DOUT1_OD**|Discrete output 1 “open drain” (60 V, 1A) 101 +|**22**|**DOUT2_OD**|Discrete output 2 “open drain” (60 V, 1A) 102 +|**23**|**DOUT3_OD**|Discrete output 3 “open drain” (60 V, 1A) 103 +|**24**|**DOUT4_OD**|Discrete output 4 “open drain” (60 V, 1A) 93 93 94 -Con tactor connectionexampleforallrelays:105 +Connection diagram of a discrete input to a dry contact output: 95 95 96 -[[image:17 74456661980-866.png||data-xwiki-image-style-alignment="center" height="211" width="282"]]107 +(% aria-label="1732121887401-555.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121887401-555.png||data-xwiki-image-style-alignment="center" height="63" width="196"]](% title="Click and drag to resize" %)(%%)Connection diagram of a discrete input to an open collector output: 97 97 109 +(% aria-label="1732122137116-973.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732122137116-973.png||data-xwiki-image-style-alignment="center" height="100" width="274"]](% title="Click and drag to resize" %)(%%)Connection diagram for a discrete input for detecting a 9-32V signal: 98 98 99 - ===X8–headerfor current sensor1===111 +(% aria-label="1732121926812-202.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121926812-202.png||data-xwiki-image-style-alignment="center" height="76" width="242"]](% title="Click and drag to resize" %)(%%)Connection diagram for discrete output: 100 100 101 - Receptacle Housing: Molex 430250400.Terminals: Molex43030113 +[[image:1739361269041-663.png||data-xwiki-image-style-alignment="center" height="93" width="275"]] 102 102 103 - [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center"height="77"width="71"]]115 +=== X4 – header for HVIL === 104 104 117 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 118 + 119 +[[image:1732122015188-642.png||data-xwiki-image-style-alignment="center" height="64" width="150"]] 120 + 105 105 |**Pin**|**Name**|**Description** 106 -|**1**|** +5V**|Supply voltagefor the currentsensor 5V, max 50 mA107 -|**2**|** GND**|Ground108 -|**3**|** CS1_OUT**|Current sensor1output109 -|**4**|** CS1_REF**|Currentsensor1 referencesignal122 +|**1**|**-**|Not used 123 +|**2**|**HVIL_OUT**|Output of the current measurement circuit in the current loop (lower potential, measuring shunt output) 124 +|**3**|**HVIL_IN**|Input of the current measurement circuit in the current loop (higher potential, measuring shunt input) 125 +|**4**|**HVIL_PWR**|Current loop power supply (max 5V, 25mA) 110 110 111 - ===X9–(%style="color:inherit;font-family:inherit;font-size:max(18px,min(20px, 14.4444px+0.462963vw))"%)headerfor current sensor2(%%)===127 + If the BMS Main 2R device generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main 2R is a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins. 112 112 113 - Receptacle Housing:Molex430250400. Terminals: Molex 43030129 +Connection diagram to the current loop: 114 114 115 -[[image:173 2198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]131 +[[image:1739361367866-742.png||data-xwiki-image-style-alignment="center" height="210" width="281"]] 116 116 133 +=== X5 – header for current and temperature sensors === 134 + 135 +Receptacle Housing: Hirose ZE05-16DS-HU/R. Terminals: Hirose ZE05-2022SCF 136 + 137 +[[image:1733311958053-469.png||data-xwiki-image-style-alignment="center" height="83" width="349"]] 138 + 139 +(% style="width:539px" %) 140 +|**Pin**|**Name**|(% style="width:402px" %)**Description** 141 +|**1**|**CS1_5V**|(% style="width:402px" %)Current sensor 1 power line (5 V, max 50 mA) 142 +|**2–6**|**GND**|(% style="width:402px" %)Ground 143 +|**7**|**CS1_IN1**|(% style="width:402px" %)Current sensor 1 signal line (for a dual-range current sensor, High range output) 144 +|**8**|**CS1_REF_IN2**|(% style="width:402px" %)Current sensor 1 reference voltage signal line (for a dual-range current sensor, Low range output) 145 +|**9**|**CS2_5V**|(% style="width:402px" %)Current sensor 2 power line (5 V, max 50 mA) 146 +|**10**|**CS2_IN1**|(% style="width:402px" %)Current sensor 2 signal line (for a dual-range current sensor, High range output) 147 +|**11**|**CS2_REF_IN2**|(% style="width:402px" %)Current sensor 2 reference voltage signal line (for a dual-range current sensor, Low range output) 148 +|**12**|**CS3_5V**|(% style="width:402px" %)Current sensor 3 power line (5 V, max 50 mA) 149 +|**13**|**CS3_IN1**|(% style="width:402px" %)Current sensor 3 signal line (for a dual-range current sensor, High range output) 150 +|**14**|**CS3_REF_IN2**|(% style="width:402px" %)Current sensor 3 reference voltage signal line (for a dual-range current sensor, Low range output) 151 +|**15**|**TEMP1**|(% style="width:402px" %)Temperature sensor 1 signal line (NTC-thermistor 100 kOhm) 152 +|**16**|**TEMP2**|(% style="width:402px" %)Temperature sensor 2 signal line (NTC-thermistor 100 kOhm) 153 + 154 +Current sensor connection diagram (using the example of LEM HASS 100-S): 155 + 156 +[[image:1733316158040-285.png||data-xwiki-image-style-alignment="center" height="170" width="412"]] 157 + 158 +Current sensor connection diagram (using the example of LEM DHAB S/118): 159 + 160 +[[image:1733316170709-142.png||data-xwiki-image-style-alignment="center" height="171" width="413"]] 161 + 162 +NTC-thermistor connection diagram: 163 + 164 +[[image:1733316189878-329.png||data-xwiki-image-style-alignment="center" height="130" width="260"]] 165 + 166 +=== X6 – header for CAN1 and RS-485-1 (external buses) === 167 + 168 +Receptacle Housing: Hirose ZE05-5S-HU/R. Terminals: Hirose ZE05-2022SCF 169 + 170 +[[image:1733316218666-814.png||data-xwiki-image-style-alignment="center" height="55" width="162"]] 171 + 117 117 |**Pin**|**Name**|**Description** 118 -|**1**|**+5V**|Supply voltage for the current sensor 5V, max 50 mA 119 -|**2**|**GND**|Ground 120 -|**3**|**CS2_OUT**|Current sensor 2 output 121 -|**4**|**CS2_REF**|Current sensor 2 reference signal 173 +|**1**|**CAN1_H**|CAN1 line H for communication with external equipment 174 +|**2**|**CAN1_L**|CAN1 line L for communication with external equipment 175 +|**3**|**CAN1_RS485_1_GND**|Ground of CAN1 and RS-485-1 176 +|**4**|**RS485_1_A**|RS-485-1 line A for communication with external equipment 177 +|**5**|**RS485_1_B**|RS-485-1 line B for communication with external equipment 122 122 123 - === X10 – (% style="color:inherit; font-family:inherit; font-size:max(18px,min(20px, 14.4444px + 0.462963vw))" %)headerfortemperaturesensors(%%)===179 +Connection diagram to the CAN1 bus: 124 124 125 - Receptacle Housing: Molex430250400.Terminals: Molex43030181 +[[image:1733316241362-843.png||data-xwiki-image-style-alignment="center" height="153" width="410"]] 126 126 127 - [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center"height="77"width="71"]]183 +Connection diagram to the RS-485-1 bus: 128 128 185 +[[image:1733316483336-290.png||data-xwiki-image-style-alignment="center" height="152" width="417"]] 186 + 187 +=== X7 – header for CAN2 (internal bus) === 188 + 189 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 190 + 191 +[[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 192 + 129 129 |**Pin**|**Name**|**Description** 130 -|**1, 2**|**GND**|Ground 131 -|**3**|**T_SENS1**|Ground 132 -|**4**|**T_SENS2**|Current sensor 2 output 194 +|**1**|**CAN2_H**|CAN2 line H for communication with other BMS devices 195 +|**2**|**CAN2_L**|CAN2 line L for communication with other BMS devices 196 +|**3**|**GND**|Ground 197 +|**4**|**CAN2_5V**|CAN2 power line (5 V, max 400 mA) 133 133 199 +Connection diagram to the CAN2 bus (using the example of connecting BMS Display 1.2): 200 + 201 +[[image:1733316563149-458.png||data-xwiki-image-style-alignment="center" height="158" width="392"]] 202 + 203 +=== X8 – header for CAN3 === 204 + 205 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 206 + 207 +[[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 208 + 209 +|**Pin**|**Name**|**Description** 210 +|**1**|**CAN3_H**|CAN3 line H 211 +|**2**|**CAN3_L**|CAN3 line L 212 +|**3**|**GND**|Ground 213 +|**4**|**CAN3_5V**|CAN3 power line (5 V, max 400 mA) 214 + 215 +(% class="box infomessage" %) 216 +((( 217 +**Note:** 218 +CAN3 operates differently depending on used firmware: 219 + 220 +* **BMS Main 3:** CAN3 bus is reserved; 221 +* **BMS Main 3X:** CAN3 bus is used to connect with BMS Main 3 inside parallel strings. Diagram for connecting battery modules to the CAN3 bus: 222 + 223 +[[image:1733316622613-181.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="417"]] 224 +))) 225 + 226 +=== X9 – header for BMS Logic (RS-485-2) === 227 + 228 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 229 + 230 +[[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 231 + 232 +|**Pin**|**Name**|**Description** 233 +|**1**|**LOGIC_B**|RS-485 line B for communication with BMS Logic 234 +|**2**|**LOGIC_A**|RS-485 line A for communication with BMS Logic 235 +|**3**|**GND**|Ground 236 +|**4**|**LOGIC_5V**|BMS Logic power line (+5V, max 400mA) 237 + 238 +(% class="box infomessage" %) 239 +((( 240 +**Note:** 241 +RS-485-2 operates differently depending on used firmware: 242 + 243 +* **BMS Main 3X:** RS-485-2 bus is reserved; 244 +* **BMS Main 3:** RS-485-2 bus is used to connect with BMS Logics in a battery pack. Connection diagram for BMS Logic devices: 245 + 246 +[[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="163" width="400"]] 247 +))) 248 + 249 +=== X10 – === 250 + 134 134 === X11 – header for high-voltage bus before contactors (plus) === 135 135 136 136 Receptacle Housing: Molex 436450200. Terminals: Molex 43030
- 1741619814065-850.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -8.9 KB - Content
- 1774456661980-866.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -13.9 KB - Content