Changes for page 2. Installation and connection
Last modified by Admin on 2026/04/02 13:49
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -96,40 +96,53 @@ 96 96 [[image:1774456661980-866.png||data-xwiki-image-style-alignment="center" height="211" width="282"]] 97 97 98 98 99 -=== X8 – header for current sensor 1===99 +=== X8 – header for current sensor === 100 100 101 -Receptacle Housing: Molex430250400. Terminals:Molex43030101 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 102 102 103 -[[image:173 2198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]103 +[[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 104 104 105 105 |**Pin**|**Name**|**Description** 106 -|**1**|** +5V**|Supplyvoltage for the current sensor5V,max 50 mA107 -|**2**|** GND**|Ground108 -|**3**|** CS1_OUT**|Current sensor 1 output109 -|**4**|**C S1_REF**|Currentsensor 1 referencesignal106 +|**1**|**CAN3_H**|CAN3 line H 107 +|**2**|**CAN3_L**|CAN3 line L 108 +|**3**|**GND**|Ground 109 +|**4**|**CAN3_5V**|CAN3 power line (5 V, max 400 mA) 110 110 111 -=== X9 – (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)header for current sensor 2(%%) === 111 +(% class="box infomessage" %) 112 +((( 113 +**Note:** 114 +CAN3 operates differently depending on used firmware: 112 112 113 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030 116 +* **BMS Main 3:** CAN3 bus is reserved; 117 +* **BMS Main 3X:** CAN3 bus is used to connect with BMS Main 3 inside parallel strings. Diagram for connecting battery modules to the CAN3 bus: 114 114 115 -[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 119 +[[image:1733316622613-181.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="417"]] 120 +))) 116 116 122 +=== X9 – header for BMS Logic (RS-485-2) === 123 + 124 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 125 + 126 +[[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 127 + 117 117 |**Pin**|**Name**|**Description** 118 -|**1**|** +5V**|Supplyvoltage forthecurrentsensor5V,max50 mA119 -|**2**|**G ND**|Ground120 -|**3**|** CS2_OUT**|Current sensor 2 output121 -|**4**|**C S2_REF**|Currentsensor2 referencesignal129 +|**1**|**LOGIC_B**|RS-485 line B for communication with BMS Logic 130 +|**2**|**LOGIC_A**|RS-485 line A for communication with BMS Logic 131 +|**3**|**GND**|Ground 132 +|**4**|**LOGIC_5V**|BMS Logic power line (+5V, max 400mA) 122 122 123 -=== X10 – (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)header for temperature sensors(%%) === 134 +(% class="box infomessage" %) 135 +((( 136 +**Note:** 137 +RS-485-2 operates differently depending on used firmware: 124 124 125 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030 139 +* **BMS Main 3X:** RS-485-2 bus is reserved; 140 +* **BMS Main 3:** RS-485-2 bus is used to connect with BMS Logics in a battery pack. Connection diagram for BMS Logic devices: 126 126 127 -[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 142 +[[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="163" width="400"]] 143 +))) 128 128 129 -|**Pin**|**Name**|**Description** 130 -|**1, 2**|**GND**|Ground 131 -|**3**|**T_SENS1**|Ground 132 -|**4**|**T_SENS2**|Current sensor 2 output 145 +=== X10 – === 133 133 134 134 === X11 – header for high-voltage bus before contactors (plus) === 135 135