Changes for page 2. Installation and connection
Last modified by Admin on 2026/04/02 13:49
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -108,93 +108,69 @@ 108 108 |**3**|**CS1_OUT**|Current sensor 1 output 109 109 |**4**|**CS1_REF**|Current sensor 1 reference signal 110 110 111 -=== X9 – header for BMSLogic(RS-485-2) ===111 +=== X9 – (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)header for current sensor 2(%%) === 112 112 113 -Receptacle Housing: HiroseZE05-4S-HU/R. Terminals:HiroseZE05-2022SCF113 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 114 114 115 -[[image:173 3316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]]115 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 116 116 117 117 |**Pin**|**Name**|**Description** 118 -|**1**|** LOGIC_B**|RS-485lineBfor communicationwithBMSLogic119 -|**2**|** LOGIC_A**|RS-485 line A forcommunication with BMS Logic120 -|**3**|** GND**|Ground121 -|**4**|** LOGIC_5V**|BMSLogicpowerline(+5V, max 400mA)118 +|**1**|**+5V**|Supply voltage for the current sensor 5V, max 50 mA 119 +|**2**|**GND**|Ground 120 +|**3**|**CS2_OUT**|Current sensor 2 output 121 +|**4**|**CS2_REF**|Current sensor 2 reference signal 122 122 123 -(% class="box infomessage" %) 124 -((( 125 -**Note:** 126 -RS-485-2 operates differently depending on used firmware: 123 +=== X10 – (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)header for temperature sensors(%%) === 127 127 128 -* **BMS Main 3X:** RS-485-2 bus is reserved; 129 -* **BMS Main 3:** RS-485-2 bus is used to connect with BMS Logics in a battery pack. Connection diagram for BMS Logic devices: 125 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 130 130 131 -[[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="163" width="400"]] 132 -))) 127 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 133 133 134 -=== X10 – === 135 - 136 -=== X11 – header for high-voltage bus before contactors (plus) === 137 - 138 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030 139 - 140 -[[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] 141 - 142 142 |**Pin**|**Name**|**Description** 143 -|**1**|**IN1+**|Plus of the high-voltage bus (before contactors) 144 -|**2**|**IN1+**|Plus of the high-voltage bus (before contactors) 130 +|**1, 2**|**GND**|Ground 131 +|**3**|**T_SENS1**|Temperature sensor 1 output 132 +|**4**|**T_SENS2**|Temperature sensor 2 output 145 145 146 -(% class="box warningmessage" %) 147 -((( 148 -The connected voltage must not exceed 1000V. 149 -))) 134 +=== X11 – (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)header for BMS Logic(%%) === 150 150 151 - === X12 – headerfor high-voltagebusbefore contactors (minus)===136 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 152 152 153 - Receptacle Housing: Molex 436450200.Terminals: Molex43030138 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 154 154 155 -[[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 156 - 157 157 |**Pin**|**Name**|**Description** 158 -|**1**|**IN1-**|Minus of the high-voltage bus (before contactors) 159 -|**2**|**IN1-**|Minus of the high-voltage bus (before contactors) 141 +|**1**|**RS_LOGIC_A**|RS-485 line A for communication with BMS Logic 142 +|**2**|**RS_LOGIC_B**|RS-485 line B for communication with BMS Logic 143 +|**3**|**+5V**|Supply voltage for BMS Logic 144 +|**4**|**GND**|Ground 160 160 161 -(% class="box warningmessage" %) 162 -((( 163 -The connected voltage must not exceed 1000V. 164 -))) 146 +=== X12 – header for internal CAN interface === 165 165 166 - === X13 – headerfor high-voltagebusaftercontactors (plus)===148 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 167 167 168 - Receptacle Housing: Molex 436450200.Terminals: Molex43030150 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 169 169 170 -[[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]] 171 - 172 172 |**Pin**|**Name**|**Description** 173 -|**1**|**IN2+**|Plus of the high-voltage bus (after contactors) 174 -|**2**|**IN2+**|Plus of the high-voltage bus (after contactors) 153 +|**1**|**CAN_INT_H**|RS-485 line A for communication with BMS Logic 154 +|**2**|**CAN_INT_L**|CAN L line for communication with external equipment 155 +|**3**|**–**|– 156 +|**4**|**GND**|Ground 175 175 176 -(% class="box warningmessage" %) 177 -((( 178 -The connected voltage must not exceed 1000V. 179 -))) 158 +=== X13 – header for external CAN and RS-485 interfaces === 180 180 181 - === X14 – headerfor high-voltagebusaftercontactors (minus)===160 +Receptacle Housing: Molex 430250600. Terminals: Molex 43030 182 182 183 - ReceptacleHousing: Molex 436450200. Terminals: Molex 43030162 +[[image:https://docs.movicomelectric.com/bin/download/Battery%20management%20systems/BMS%20Main%202.1/2.%20Installation%20and%20connection/WebHome/1731517180930-597.png?width=113&height=81&rev=1.1||alt="1731517180930-597.png" data-xwiki-image-style-alignment="center" height="81" width="113"]] 184 184 185 -[[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]] 186 - 187 187 |**Pin**|**Name**|**Description** 188 -|**1**|**IN2-**|Minus of the high-voltage bus (after contactors) 189 -|**2**|**IN2-**|Minus of the high-voltage bus (after contactors) 165 +|**1**|**RS_EXT_A**|RS-485 line A for communication with external equipment 166 +|**2**|**CAN_EXT_H**|CAN H line for communication with external equipment 167 +|**3**|**+5V**|Supply voltage 5V for external devices, max 200 mA 168 +|**4**|**RS_EXT_B**|RS-485 line B for communication with external equipment 169 +|**5**|**CAN_EXT_L**|CAN L line for communication with external equipment 170 +|**6**|**GND**|Ground 190 190 191 -(% class="box warningmessage" %) 192 -((( 193 -The connected voltage must not exceed 1000V. 194 -))) 172 +=== J1 – jumper for switching RS-485 bus terminal resistor === 195 195 196 -=== J1 – jumper for switching RS-485-1 bus terminal resistor === 197 - 198 198 [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]] 199 199 200 200 To connect a terminal resistor between the **RS485_1_A** and **RS485_1_B** lines, install a jumper. The jumper is installed according to the table: