Changes for page 2. Installation and connection
Last modified by Admin on 2026/04/02 13:49
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -96,69 +96,53 @@ 96 96 [[image:1774456661980-866.png||data-xwiki-image-style-alignment="center" height="211" width="282"]] 97 97 98 98 99 -=== X8 – header for current sensor === 99 +=== X8 – header for current sensor 1 === 100 100 101 -Receptacle Housing: HiroseZE05-4S-HU/R. Terminals:HiroseZE05-2022SCF101 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 102 102 103 -[[image:173 3316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]]103 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 104 104 105 105 |**Pin**|**Name**|**Description** 106 -|**1**|** CAN3_H**|CAN3lineH107 -|**2**|** CAN3_L**|CAN3 line L108 -|**3**|** GND**|Ground109 -|**4**|**C AN3_5V**|CAN3powerline(5 V, max 400 mA)106 +|**1**|**+5V**|Supply voltage for the current sensor 5V, max 50 mA 107 +|**2**|**GND**|Ground 108 +|**3**|**CS1_OUT**|Current sensor 1 output 109 +|**4**|**CS1_REF**|Current sensor 1 reference signal 110 110 111 -(% class="box infomessage" %) 112 -((( 113 -**Note:** 114 -CAN3 operates differently depending on used firmware: 111 +=== X9 – (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)header for current sensor 2(%%) === 115 115 116 -* **BMS Main 3:** CAN3 bus is reserved; 117 -* **BMS Main 3X:** CAN3 bus is used to connect with BMS Main 3 inside parallel strings. Diagram for connecting battery modules to the CAN3 bus: 113 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 118 118 119 -[[image:1733316622613-181.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="417"]] 120 -))) 115 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 121 121 122 -=== X9 – header for BMS Logic (RS-485-2) === 123 - 124 -Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 125 - 126 -[[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 127 - 128 128 |**Pin**|**Name**|**Description** 129 -|**1**|** LOGIC_B**|RS-485lineBfor communicationwithBMSLogic130 -|**2**|** LOGIC_A**|RS-485 line A forcommunication with BMS Logic131 -|**3**|** GND**|Ground132 -|**4**|** LOGIC_5V**|BMSLogicpowerline(+5V, max 400mA)118 +|**1**|**+5V**|Supply voltage for the current sensor 5V, max 50 mA 119 +|**2**|**GND**|Ground 120 +|**3**|**CS2_OUT**|Current sensor 2 output 121 +|**4**|**CS2_REF**|Current sensor 2 reference signal 133 133 134 -(% class="box infomessage" %) 135 -((( 136 -**Note:** 137 -RS-485-2 operates differently depending on used firmware: 123 +=== X10 – (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)header for temperature sensors(%%) === 138 138 139 -* **BMS Main 3X:** RS-485-2 bus is reserved; 140 -* **BMS Main 3:** RS-485-2 bus is used to connect with BMS Logics in a battery pack. Connection diagram for BMS Logic devices: 125 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 141 141 142 -[[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="163" width="400"]] 143 -))) 127 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 144 144 145 -=== X10 – === 129 +|**Pin**|**Name**|**Description** 130 +|**1, 2**|**GND**|Ground 131 +|**3**|**T_SENS1**|Temperature sensor 1 output 132 +|**4**|**T_SENS2**|Temperature sensor 2 output 146 146 147 -=== X11 – he ader for high-voltagebusbeforecontactors(plus) ===134 +=== X11 – (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)header for BMS Logic(%%) === 148 148 149 -Receptacle Housing: Molex 43 6450200. Terminals: Molex 43030136 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 150 150 151 -[[image:173 3316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]]138 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]] 152 152 153 153 |**Pin**|**Name**|**Description** 154 -|**1**|**IN1+**|Plus of the high-voltage bus (before contactors) 155 -|**2**|**IN1+**|Plus of the high-voltage bus (before contactors) 141 +|**1**|**RS485_A**|RS-485 line A for communication with BMS Logic 142 +|**2**|**RS485_B**|RS-485 line B for communication with BMS Logic 143 +|**3**|**+5V**|Supply voltage for BMS Logic 144 +|**4**|**GND**|Ground 156 156 157 -(% class="box warningmessage" %) 158 -((( 159 -The connected voltage must not exceed 1000V. 160 -))) 161 - 162 162 === X12 – header for high-voltage bus before contactors (minus) === 163 163 164 164 Receptacle Housing: Molex 436450200. Terminals: Molex 43030