... ... @@ -96,116 +96,81 @@
96 96  [[image:1774456661980-866.png||data-xwiki-image-style-alignment="center" height="211" width="282"]]
97 97  
98 98  
99 -=== X8 – header for current sensor ===
99 +=== X8 – header for current sensor 1 ===
100 100  
101 -Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF
101 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030
102 102  
103 -[[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]]
103 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]
104 104  
105 105  |**Pin**|**Name**|**Description**
106 -|**1**|**CAN3_H**|CAN3 line H
107 -|**2**|**CAN3_L**|CAN3 line L
108 -|**3**|**GND**|Ground
109 -|**4**|**CAN3_5V**|CAN3 power line (5 V, max 400 mA)
106 +|**1**|**+5V**|Supply voltage for the current sensor 5V, max 50 mA
107 +|**2**|**GND**|Ground
108 +|**3**|**CS1_OUT**|Current sensor 1 output
109 +|**4**|**CS1_REF**|Current sensor 1 reference signal
110 110  
111 -(% class="box infomessage" %)
112 -(((
113 -**Note:**
114 -CAN3 operates differently depending on used firmware:
111 +=== X9 – (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)header for current sensor 2(%%) ===
115 115  
116 -* **BMS Main 3:** CAN3 bus is reserved;
117 -* **BMS Main 3X:** CAN3 bus is used to connect with BMS Main 3 inside parallel strings. Diagram for connecting battery modules to the CAN3 bus:
113 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030
118 118  
119 -[[image:1733316622613-181.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="417"]]
120 -)))
115 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]
121 121  
122 -=== X9 – header for BMS Logic (RS-485-2) ===
123 -
124 -Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF
125 -
126 -[[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]]
127 -
128 128  |**Pin**|**Name**|**Description**
129 -|**1**|**LOGIC_B**|RS-485 line B for communication with BMS Logic
130 -|**2**|**LOGIC_A**|RS-485 line A for communication with BMS Logic
131 -|**3**|**GND**|Ground
132 -|**4**|**LOGIC_5V**|BMS Logic power line (+5V, max 400mA)
118 +|**1**|**+5V**|Supply voltage for the current sensor 5V, max 50 mA
119 +|**2**|**GND**|Ground
120 +|**3**|**CS2_OUT**|Current sensor 2 output
121 +|**4**|**CS2_REF**|Current sensor 2 reference signal
133 133  
134 -(% class="box infomessage" %)
135 -(((
136 -**Note:**
137 -RS-485-2 operates differently depending on used firmware:
123 +=== X10 – (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)header for temperature sensors(%%) ===
138 138  
139 -* **BMS Main 3X:** RS-485-2 bus is reserved;
140 -* **BMS Main 3:** RS-485-2 bus is used to connect with BMS Logics in a battery pack. Connection diagram for BMS Logic devices:
125 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030
141 141  
142 -[[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="163" width="400"]]
143 -)))
127 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]
144 144  
145 -=== X10 – ===
146 -
147 -=== X11 – header for high-voltage bus before contactors (plus) ===
148 -
149 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030
150 -
151 -[[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]]
152 -
153 153  |**Pin**|**Name**|**Description**
154 -|**1**|**IN1+**|Plus of the high-voltage bus (before contactors)
155 -|**2**|**IN1+**|Plus of the high-voltage bus (before contactors)
130 +|**1, 2**|**GND**|Ground
131 +|**3**|**T_SENS1**|Temperature sensor 1 output
132 +|**4**|**T_SENS2**|Temperature sensor 2 output
156 156  
157 -(% class="box warningmessage" %)
158 -(((
159 -The connected voltage must not exceed 1000V.
160 -)))
134 +=== X11 – (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)header for BMS Logic(%%) ===
161 161  
162 -=== X12 – header for high-voltage bus before contactors (minus) ===
136 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030
163 163  
164 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030
138 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]
165 165  
166 -[[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]]
167 -
168 168  |**Pin**|**Name**|**Description**
169 -|**1**|**IN1-**|Minus of the high-voltage bus (before contactors)
170 -|**2**|**IN1-**|Minus of the high-voltage bus (before contactors)
141 +|**1**|**RS_LOGIC_A**|RS-485 line A for communication with BMS Logic
142 +|**2**|**RS_LOGIC_B**|RS-485 line B for communication with BMS Logic
143 +|**3**|**+5V**|Supply voltage for BMS Logic
144 +|**4**|**GND**|Ground
171 171  
172 -(% class="box warningmessage" %)
173 -(((
174 -The connected voltage must not exceed 1000V.
175 -)))
146 +=== X12 – header for internal CAN interface ===
176 176  
177 -=== X13 – header for high-voltage bus after contactors (plus) ===
148 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030
178 178  
179 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030
150 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]
180 180  
181 -[[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]]
182 -
183 183  |**Pin**|**Name**|**Description**
184 -|**1**|**IN2+**|Plus of the high-voltage bus (after contactors)
185 -|**2**|**IN2+**|Plus of the high-voltage bus (after contactors)
153 +|**1**|**CAN_INT_H**|RS-485 line A for communication with BMS Logic
154 +|**2**|**CAN_INT_L**|CAN L line for communication with external equipment
155 +|**3**|**–**|–
156 +|**4**|**GND**|Ground
186 186  
187 -(% class="box warningmessage" %)
188 -(((
189 -The connected voltage must not exceed 1000V.
190 -)))
158 +=== X13 – header for external CAN and RS-485 interfaces ===
191 191  
192 -=== X14 – header for high-voltage bus after contactors (minus) ===
160 +Receptacle Housing: Molex 430250600. Terminals: Molex 43030
193 193  
194 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030
162 +[[image:https://docs.movicomelectric.com/bin/download/Battery%20management%20systems/BMS%20Main%202.1/2.%20Installation%20and%20connection/WebHome/1731517180930-597.png?width=113&height=81&rev=1.1||alt="1731517180930-597.png" data-xwiki-image-style-alignment="center" height="81" width="113"]]
195 195  
196 -[[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]]
197 -
198 198  |**Pin**|**Name**|**Description**
199 -|**1**|**IN2-**|Minus of the high-voltage bus (after contactors)
200 -|**2**|**IN2-**|Minus of the high-voltage bus (after contactors)
165 +|**1**|**RS_EXT_A**|RS-485 line A for communication with external equipment
166 +|**2**|**CAN_EXT_H**|CAN H line for communication with external equipment
167 +|**3**|**+5V**|Supply voltage 5V for external devices, max 200 mA
168 +|**4**|**RS_EXT_B**|RS-485 line B for communication with external equipment
169 +|**5**|**CAN_EXT_L**|CAN L line for communication with external equipment
170 +|**6**|**GND**|Ground
201 201  
202 -(% class="box warningmessage" %)
203 -(((
204 -The connected voltage must not exceed 1000V.
205 -)))
172 +=== J1 – jumper for switching RS-485 bus terminal resistor ===
206 206  
207 -=== J1 – jumper for switching RS-485-1 bus terminal resistor ===
208 -
209 209  [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]
210 210  
211 211  To connect a terminal resistor between the **RS485_1_A** and **RS485_1_B** lines, install a jumper. The jumper is installed according to the table: