Changes for page 2. Installation and connection
Last modified by Admin on 2026/04/02 13:49
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -85,8 +85,10 @@ 85 85 86 86 Receptacle Housing: Molex 39012020. Terminals: Molex 5556 87 87 88 -[[image:1732198827034-560.png ||data-xwiki-image-style-alignment="center" height="78" width="41"]]88 +[[image:https://docs.movicomelectric.com/bin/download/Battery%20management%20systems/BMS%20Main%202.1/2.%20Installation%20and%20connection/WebHome/1732198827034-560.png?width=41&height=78&rev=1.1||alt="1732198827034-560.png" height="78" width="41"]] 89 89 90 +By default, relay 1 is used to control the discharging contactor. 91 + 90 90 |**Pin**|**Name**|**Description** 91 91 |**1**|**V+**|Switching voltage (up to 55V, max 3A) 92 92 |**2**|**NO**|Normally open contact ... ... @@ -93,16 +93,105 @@ 93 93 94 94 Contactor connection example for all relays: 95 95 96 -[[image:17 74456661980-866.png||data-xwiki-image-style-alignment="center" height="211" width="282"]]98 +[[image:https://docs.movicomelectric.com/bin/download/Battery%20management%20systems/BMS%20Main%202.1/2.%20Installation%20and%20connection/WebHome/1741619814065-850.png?width=252&height=189&rev=1.1||alt="1741619814065-850.png" height="189" width="252"]] 97 97 100 +[[image:1739361269041-663.png||data-xwiki-image-style-alignment="center" height="93" width="275"]] 98 98 99 -=== X 8– header forcurrentsensor===102 +=== X4 – header for HVIL === 100 100 101 101 Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 102 102 106 +[[image:1732122015188-642.png||data-xwiki-image-style-alignment="center" height="64" width="150"]] 107 + 108 +|**Pin**|**Name**|**Description** 109 +|**1**|**-**|Not used 110 +|**2**|**HVIL_OUT**|Output of the current measurement circuit in the current loop (lower potential, measuring shunt output) 111 +|**3**|**HVIL_IN**|Input of the current measurement circuit in the current loop (higher potential, measuring shunt input) 112 +|**4**|**HVIL_PWR**|Current loop power supply (max 5V, 25mA) 113 + 114 + If the BMS Main 2R device generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main 2R is a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins. 115 + 116 +Connection diagram to the current loop: 117 + 118 +[[image:1739361367866-742.png||data-xwiki-image-style-alignment="center" height="210" width="281"]] 119 + 120 +=== X5 – header for current and temperature sensors === 121 + 122 +Receptacle Housing: Hirose ZE05-16DS-HU/R. Terminals: Hirose ZE05-2022SCF 123 + 124 +[[image:1733311958053-469.png||data-xwiki-image-style-alignment="center" height="83" width="349"]] 125 + 126 +(% style="width:539px" %) 127 +|**Pin**|**Name**|(% style="width:402px" %)**Description** 128 +|**1**|**CS1_5V**|(% style="width:402px" %)Current sensor 1 power line (5 V, max 50 mA) 129 +|**2–6**|**GND**|(% style="width:402px" %)Ground 130 +|**7**|**CS1_IN1**|(% style="width:402px" %)Current sensor 1 signal line (for a dual-range current sensor, High range output) 131 +|**8**|**CS1_REF_IN2**|(% style="width:402px" %)Current sensor 1 reference voltage signal line (for a dual-range current sensor, Low range output) 132 +|**9**|**CS2_5V**|(% style="width:402px" %)Current sensor 2 power line (5 V, max 50 mA) 133 +|**10**|**CS2_IN1**|(% style="width:402px" %)Current sensor 2 signal line (for a dual-range current sensor, High range output) 134 +|**11**|**CS2_REF_IN2**|(% style="width:402px" %)Current sensor 2 reference voltage signal line (for a dual-range current sensor, Low range output) 135 +|**12**|**CS3_5V**|(% style="width:402px" %)Current sensor 3 power line (5 V, max 50 mA) 136 +|**13**|**CS3_IN1**|(% style="width:402px" %)Current sensor 3 signal line (for a dual-range current sensor, High range output) 137 +|**14**|**CS3_REF_IN2**|(% style="width:402px" %)Current sensor 3 reference voltage signal line (for a dual-range current sensor, Low range output) 138 +|**15**|**TEMP1**|(% style="width:402px" %)Temperature sensor 1 signal line (NTC-thermistor 100 kOhm) 139 +|**16**|**TEMP2**|(% style="width:402px" %)Temperature sensor 2 signal line (NTC-thermistor 100 kOhm) 140 + 141 +Current sensor connection diagram (using the example of LEM HASS 100-S): 142 + 143 +[[image:1733316158040-285.png||data-xwiki-image-style-alignment="center" height="170" width="412"]] 144 + 145 +Current sensor connection diagram (using the example of LEM DHAB S/118): 146 + 147 +[[image:1733316170709-142.png||data-xwiki-image-style-alignment="center" height="171" width="413"]] 148 + 149 +NTC-thermistor connection diagram: 150 + 151 +[[image:1733316189878-329.png||data-xwiki-image-style-alignment="center" height="130" width="260"]] 152 + 153 +=== X6 – header for CAN1 and RS-485-1 (external buses) === 154 + 155 +Receptacle Housing: Hirose ZE05-5S-HU/R. Terminals: Hirose ZE05-2022SCF 156 + 157 +[[image:1733316218666-814.png||data-xwiki-image-style-alignment="center" height="55" width="162"]] 158 + 159 +|**Pin**|**Name**|**Description** 160 +|**1**|**CAN1_H**|CAN1 line H for communication with external equipment 161 +|**2**|**CAN1_L**|CAN1 line L for communication with external equipment 162 +|**3**|**CAN1_RS485_1_GND**|Ground of CAN1 and RS-485-1 163 +|**4**|**RS485_1_A**|RS-485-1 line A for communication with external equipment 164 +|**5**|**RS485_1_B**|RS-485-1 line B for communication with external equipment 165 + 166 +Connection diagram to the CAN1 bus: 167 + 168 +[[image:1733316241362-843.png||data-xwiki-image-style-alignment="center" height="153" width="410"]] 169 + 170 +Connection diagram to the RS-485-1 bus: 171 + 172 +[[image:1733316483336-290.png||data-xwiki-image-style-alignment="center" height="152" width="417"]] 173 + 174 +=== X7 – header for CAN2 (internal bus) === 175 + 176 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 177 + 103 103 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 104 104 105 105 |**Pin**|**Name**|**Description** 181 +|**1**|**CAN2_H**|CAN2 line H for communication with other BMS devices 182 +|**2**|**CAN2_L**|CAN2 line L for communication with other BMS devices 183 +|**3**|**GND**|Ground 184 +|**4**|**CAN2_5V**|CAN2 power line (5 V, max 400 mA) 185 + 186 +Connection diagram to the CAN2 bus (using the example of connecting BMS Display 1.2): 187 + 188 +[[image:1733316563149-458.png||data-xwiki-image-style-alignment="center" height="158" width="392"]] 189 + 190 +=== X8 – header for CAN3 === 191 + 192 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 193 + 194 +[[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 195 + 196 +|**Pin**|**Name**|**Description** 106 106 |**1**|**CAN3_H**|CAN3 line H 107 107 |**2**|**CAN3_L**|CAN3 line L 108 108 |**3**|**GND**|Ground
- 1774456661980-866.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -13.9 KB - Content