Last modified by Admin on 2026/04/02 13:49

From version 86.2
edited by Admin
on 2026/03/25 16:38
Change comment: There is no comment for this version
To version 81.5
edited by Admin
on 2026/03/25 16:34
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -65,44 +65,148 @@
65 65  
66 66  
67 67  
68 -=== X2 – miniUSB connector ===
68 +=== X2 – ===
69 69  
70 -The miniUSB connector is used to configure the parameters of the BMS Main 2R device.
70 +=== P1 header for power supply ===
71 71  
72 -=== (% title="Click and drag to resize" %)​(%%)X3 – (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)header for power supply(%%) ===
73 -
74 74  Receptacle Housing: Molex 39012020. Terminals: Molex 5556
75 75  
76 -[[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]]
74 +[[image:https://docs.movicomelectric.com/bin/download/Battery%20management%20systems/BMS%20Main%202.1/2.%20Installation%20and%20connection/WebHome/1732198827034-560.png?width=41&height=78&rev=1.1||alt="1732198827034-560.png" height="78" width="41"]]
77 77  
78 78  |**Pin**|**Name**|**Description**
79 79  |**1**|**GND**|Ground
80 -|**2**|**V+**|Supply voltage (9-32V)
78 +|**2**|**V+**|Supply voltage 9-30V
81 81  
80 + Contactor connection diagram:
82 82  
82 +(% aria-label="1732121755886-234.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121755886-234.png||data-xwiki-image-style-alignment="center" height="82" width="260"]]
83 83  
84 -=== X4, X5, X6, X7 header of relay 1, 2, 3 and 4 ===
84 +=== (% title="Click and drag to resize" %)​(%%)X3 header for discrete inputs and outputs ===
85 85  
86 -Receptacle Housing: Molex 39012020. Terminals: Molex 5556
86 +Receptacle Housing: Hirose ZE05-24DS-HU/R. Terminals: Hirose ZE05-2022SCF
87 87  
88 -[[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]]
88 +(% aria-label="1732121811285-182.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121811285-182.png||data-xwiki-image-style-alignment="center" height="94" width="531"]]
89 89  
90 90  |**Pin**|**Name**|**Description**
91 -|**1**|**V+**|Switching voltage (up to 55V, max 3A)
92 -|**2**|**NO**|Normally open contact
91 +|**1–8, 12, 16–17, 21**|**DIO_GND**|Ground of input and output signals
92 +|**9**|**DIN1_SIGNAL**|Discrete input 1 “dry contact”
93 +|**10**|**DIN2_SIGNAL**|Discrete input 2 “dry contact”
94 +|**11**|**DIN3_SIGNAL**|Discrete input 3 “dry contact”
95 +|**13**|**DIN4_SIGNAL**|Discrete input 4 “dry contact”
96 +|**14**|**DIN5_SIGNAL**|Discrete input 5 “dry contact”
97 +|**15**|**DIN6_SIGNAL**|Discrete input 6 “dry contact”
98 +|**18**|**DIN7_VIN**|Discrete input 7 (signal detection with voltage 9-32V)
99 +|**19**|**DIN8_VIN**|Discrete input 8 (signal detection with voltage 9-32V)
100 +|**20**|**DOUT1_OD**|Discrete output 1 “open drain” (60 V, 1A)
101 +|**22**|**DOUT2_OD**|Discrete output 2 “open drain” (60 V, 1A)
102 +|**23**|**DOUT3_OD**|Discrete output 3 “open drain” (60 V, 1A)
103 +|**24**|**DOUT4_OD**|Discrete output 4 “open drain” (60 V, 1A)
93 93  
94 -Contactor connection example for all relays:
105 +Connection diagram of a discrete input to a dry contact output:
95 95  
96 -[[image:1774456661980-866.png||data-xwiki-image-style-alignment="center" height="211" width="282"]]
107 +(% aria-label="1732121887401-555.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121887401-555.png||data-xwiki-image-style-alignment="center" height="63" width="196"]](% title="Click and drag to resize" %)​(%%)Connection diagram of a discrete input to an open collector output:
97 97  
109 +(% aria-label="1732122137116-973.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732122137116-973.png||data-xwiki-image-style-alignment="center" height="100" width="274"]](% title="Click and drag to resize" %)​(%%)Connection diagram for a discrete input for detecting a 9-32V signal:
98 98  
99 -=== X8 header for current sensor ===
111 +(% aria-label="1732121926812-202.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121926812-202.png||data-xwiki-image-style-alignment="center" height="76" width="242"]](% title="Click and drag to resize" %)​(%%)Connection diagram for discrete output:
100 100  
113 +[[image:1739361269041-663.png||data-xwiki-image-style-alignment="center" height="93" width="275"]]
114 +
115 +=== X4 – header for HVIL ===
116 +
101 101  Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF
102 102  
119 +[[image:1732122015188-642.png||data-xwiki-image-style-alignment="center" height="64" width="150"]]
120 +
121 +|**Pin**|**Name**|**Description**
122 +|**1**|**-**|Not used
123 +|**2**|**HVIL_OUT**|Output of the current measurement circuit in the current loop (lower potential, measuring shunt output)
124 +|**3**|**HVIL_IN**|Input of the current measurement circuit in the current loop (higher potential, measuring shunt input)
125 +|**4**|**HVIL_PWR**|Current loop power supply (max 5V, 25mA)
126 +
127 + If the BMS Main 2R device generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main 2R is a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins.
128 +
129 +Connection diagram to the current loop:
130 +
131 +[[image:1739361367866-742.png||data-xwiki-image-style-alignment="center" height="210" width="281"]]
132 +
133 +=== X5 – header for current and temperature sensors ===
134 +
135 +Receptacle Housing: Hirose ZE05-16DS-HU/R. Terminals: Hirose ZE05-2022SCF
136 +
137 +[[image:1733311958053-469.png||data-xwiki-image-style-alignment="center" height="83" width="349"]]
138 +
139 +(% style="width:539px" %)
140 +|**Pin**|**Name**|(% style="width:402px" %)**Description**
141 +|**1**|**CS1_5V**|(% style="width:402px" %)Current sensor 1 power line (5 V, max 50 mA)
142 +|**2–6**|**GND**|(% style="width:402px" %)Ground
143 +|**7**|**CS1_IN1**|(% style="width:402px" %)Current sensor 1 signal line (for a dual-range current sensor, High range output)
144 +|**8**|**CS1_REF_IN2**|(% style="width:402px" %)Current sensor 1 reference voltage signal line (for a dual-range current sensor, Low range output)
145 +|**9**|**CS2_5V**|(% style="width:402px" %)Current sensor 2 power line (5 V, max 50 mA)
146 +|**10**|**CS2_IN1**|(% style="width:402px" %)Current sensor 2 signal line (for a dual-range current sensor, High range output)
147 +|**11**|**CS2_REF_IN2**|(% style="width:402px" %)Current sensor 2 reference voltage signal line (for a dual-range current sensor, Low range output)
148 +|**12**|**CS3_5V**|(% style="width:402px" %)Current sensor 3 power line (5 V, max 50 mA)
149 +|**13**|**CS3_IN1**|(% style="width:402px" %)Current sensor 3 signal line (for a dual-range current sensor, High range output)
150 +|**14**|**CS3_REF_IN2**|(% style="width:402px" %)Current sensor 3 reference voltage signal line (for a dual-range current sensor, Low range output)
151 +|**15**|**TEMP1**|(% style="width:402px" %)Temperature sensor 1 signal line (NTC-thermistor 100 kOhm)
152 +|**16**|**TEMP2**|(% style="width:402px" %)Temperature sensor 2 signal line (NTC-thermistor 100 kOhm)
153 +
154 +Current sensor connection diagram (using the example of LEM HASS 100-S):
155 +
156 +[[image:1733316158040-285.png||data-xwiki-image-style-alignment="center" height="170" width="412"]]
157 +
158 +Current sensor connection diagram (using the example of LEM DHAB S/118):
159 +
160 +[[image:1733316170709-142.png||data-xwiki-image-style-alignment="center" height="171" width="413"]]
161 +
162 +NTC-thermistor connection diagram:
163 +
164 +[[image:1733316189878-329.png||data-xwiki-image-style-alignment="center" height="130" width="260"]]
165 +
166 +=== X6 – header for CAN1 and RS-485-1 (external buses) ===
167 +
168 +Receptacle Housing: Hirose ZE05-5S-HU/R. Terminals: Hirose ZE05-2022SCF
169 +
170 +[[image:1733316218666-814.png||data-xwiki-image-style-alignment="center" height="55" width="162"]]
171 +
172 +|**Pin**|**Name**|**Description**
173 +|**1**|**CAN1_H**|CAN1 line H for communication with external equipment
174 +|**2**|**CAN1_L**|CAN1 line L for communication with external equipment
175 +|**3**|**CAN1_RS485_1_GND**|Ground of CAN1 and RS-485-1
176 +|**4**|**RS485_1_A**|RS-485-1 line A for communication with external equipment
177 +|**5**|**RS485_1_B**|RS-485-1 line B for communication with external equipment
178 +
179 +Connection diagram to the CAN1 bus:
180 +
181 +[[image:1733316241362-843.png||data-xwiki-image-style-alignment="center" height="153" width="410"]]
182 +
183 +Connection diagram to the RS-485-1 bus:
184 +
185 +[[image:1733316483336-290.png||data-xwiki-image-style-alignment="center" height="152" width="417"]]
186 +
187 +=== X7 – header for CAN2 (internal bus) ===
188 +
189 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF
190 +
103 103  [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]]
104 104  
105 105  |**Pin**|**Name**|**Description**
194 +|**1**|**CAN2_H**|CAN2 line H for communication with other BMS devices
195 +|**2**|**CAN2_L**|CAN2 line L for communication with other BMS devices
196 +|**3**|**GND**|Ground
197 +|**4**|**CAN2_5V**|CAN2 power line (5 V, max 400 mA)
198 +
199 +Connection diagram to the CAN2 bus (using the example of connecting BMS Display 1.2):
200 +
201 +[[image:1733316563149-458.png||data-xwiki-image-style-alignment="center" height="158" width="392"]]
202 +
203 +=== X8 – header for CAN3 ===
204 +
205 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF
206 +
207 +[[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]]
208 +
209 +|**Pin**|**Name**|**Description**
106 106  |**1**|**CAN3_H**|CAN3 line H
107 107  |**2**|**CAN3_L**|CAN3 line L
108 108  |**3**|**GND**|Ground
... ... @@ -142,8 +142,10 @@
142 142  [[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="163" width="400"]]
143 143  )))
144 144  
145 -=== X10 – ===
249 +=== X10 – miniUSB connector ===
146 146  
251 +The miniUSB connector is used to configure the parameters of the BMS Main 2R device.
252 +
147 147  === X11 – header for high-voltage bus before contactors (plus) ===
148 148  
149 149  Receptacle Housing: Molex 436450200. Terminals: Molex 43030
1741619814065-850.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -8.9 KB
Content
1774456661980-866.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -13.9 KB
Content