Changes for page 2. Installation and connection
Last modified by Admin on 2026/04/02 13:49
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 13 removed)
Details
- Page properties
-
- Content
-
... ... @@ -19,24 +19,24 @@ 19 19 20 20 == Installation procedure == 21 21 22 -The mounting location of the BMS Main 2Rdevice must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors.22 +The mounting location of the BMS Main 3 / BMS Main 3X device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors. 23 23 24 24 Overall and mounting dimensions are shown in figure below. 25 25 26 -[[image:17 74349658793-888.0b.STEP.JPG||data-xwiki-image-style-alignment="center" height="522" width="450"]](% title="Click and drag to resize" %)26 +(% data-widget="image" contenteditable="false" tabindex="-1" %)[[image:1733311711953-224.png||data-xwiki-image-style-alignment="center" height="566" width="775"]](% title="Click and drag to resize" %) 27 27 28 28 |**Parameter**|**Value** 29 -|Overall dimensions (length × width × height), mm| 120 × 120× 1630 -|Mounting dimensions (length × width), mm|1 14 × 11429 +|Overall dimensions (length × width × height), mm|200 × 123 × 12 30 +|Mounting dimensions (length × width), mm|194 × 114 31 31 |Mounting holes|M3 32 32 33 33 == Headers == 34 34 35 -The location and designation of connectors on the BMS Main 2Rdevice are shown below.35 +The location and designation of connectors on the BMS Main 3 / BMS Main 3X device are shown below. 36 36 37 37 (% contenteditable="false" tabindex="-1" %) 38 38 ((( 39 -[[image:17 74455018488-627.png||data-xwiki-image-style-alignment="center"]]39 +[[image:1732119505664-787.png||data-xwiki-image-style-alignment="center" height="417" width="684"]] 40 40 ))) 41 41 42 42 (% class="box warningmessage" %) ... ... @@ -45,64 +45,168 @@ 45 45 All headers are shown from the device side! 46 46 ))) 47 47 48 -=== X1 – header for discreteinputs and outputs===48 +=== X1 – header to power the device === 49 49 50 50 Receptacle Housing: Hirose ZE05-8DS-HU/R. Terminals: Hirose ZE05-2022SCF 51 51 52 52 (% class="wikigeneratedid" id="H" %) 53 -[[image:17321 98937514-731.png||data-xwiki-image-style-alignment="center" height="85" width="272"]]53 +(% data-widget="image" contenteditable="false" tabindex="-1" %)[[image:1732121673277-246.png||data-xwiki-image-style-alignment="center" height="85" width="200"]] 54 54 55 55 |**Pin**|**Name**|**Description** 56 -|**1–8**|**GND**|Ground 57 -|**9**|**DO_1**|Discrete output 1 (+5V, 20mA) 58 -|**10**|**DO_2**|Discrete output 2 (+5V, 20mA) 59 -|**11**|**DO_3**|Discrete output 3 (+5V, 20mA) 60 -|**12**|**DO_4**|Discrete output 4 (+5V, 20mA) 61 -|**13**|**DI_4**|Discrete input 4 (“dry contact”, +5V) 62 -|**14**|**DI_3**|Discrete input 3 (“dry contact”, +5V) 63 -|**15**|**DI_2**|Discrete input 2 (“dry contact”, +5V) 64 -|**16**|**DI_1**|Discrete input 1 (“dry contact”, +5V) 56 +|**1–2, 5–6**|**GND**|Ground 57 +|**3**|**KEYRUN**|Power-on signal 58 +|**4**|**CHARGE_ON**|Power-on signal (battery charge requirement) 59 +|**7–8**|**VIN**|Power line (9-32V) 65 65 61 +Power supply connection diagram: 66 66 63 +(% aria-label="1732120054870-496.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732120054870-496.png||data-xwiki-image-style-alignment="center" height="169" width="327"]] 67 67 68 -=== X2 – miniUSBconnector ===65 +=== X2 – header for contactors === 69 69 70 - TheminiUSBconnector is usedtoconfigurethe parametersof theBMSMain2R device.67 +Receptacle Housing: Hirose ZE05-12DS-HU/R. Terminals: Hirose ZE05-2022SCF 71 71 72 - ===(%title="Click anddragto resize"%)(%%)X3 – (% style="color:inherit;font-family:inherit; font-size:max(18px,min(20px,14.4444px+0.462963vw))"%)headerforpowersupply(%%)===69 +(% aria-label="1732121695049-411.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121695049-411.png||data-xwiki-image-style-alignment="center" height="87" width="267"]](% title="Click and drag to resize" %) 73 73 74 -Receptacle Housing: Molex 39012020. Terminals: Molex 5556 71 +|**Pin**|**Name**|**Description** 72 +|**1–4, 8–9**|**GND**|Ground 73 +|**5**|**CONT1_OUT**|Contactor control 1 (plus) 74 +|**6**|**CONT2_OUT**|Contactor control 2 (plus) 75 +|**7**|**CONT3_OUT**|Contactor control 3 (plus) 76 +|**10**|**CONT4_OUT**|Contactor control 4 (plus) 77 +|**11**|**CONT5_OUT**|Contactor control 5 (plus) 78 +|**12**|**CONT6_OUT**|Contactor control 6 (plus) 75 75 76 - [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center"height="78" width="41"]]80 + Contactor connection diagram: 77 77 82 +(% aria-label="1732121755886-234.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121755886-234.png||data-xwiki-image-style-alignment="center" height="82" width="260"]] 83 + 84 +=== (% title="Click and drag to resize" %)(%%)X3 – header for discrete inputs and outputs === 85 + 86 +Receptacle Housing: Hirose ZE05-24DS-HU/R. Terminals: Hirose ZE05-2022SCF 87 + 88 +(% aria-label="1732121811285-182.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121811285-182.png||data-xwiki-image-style-alignment="center" height="94" width="531"]] 89 + 78 78 |**Pin**|**Name**|**Description** 79 -|**1**|**GND**|Ground 80 -|**2**|**V+**|Supply voltage (9-32V) 91 +|**1–8, 12, 16–17, 21**|**DIO_GND**|Ground of input and output signals 92 +|**9**|**DIN1_SIGNAL**|Discrete input 1 “dry contact” 93 +|**10**|**DIN2_SIGNAL**|Discrete input 2 “dry contact” 94 +|**11**|**DIN3_SIGNAL**|Discrete input 3 “dry contact” 95 +|**13**|**DIN4_SIGNAL**|Discrete input 4 “dry contact” 96 +|**14**|**DIN5_SIGNAL**|Discrete input 5 “dry contact” 97 +|**15**|**DIN6_SIGNAL**|Discrete input 6 “dry contact” 98 +|**18**|**DIN7_VIN**|Discrete input 7 (signal detection with voltage 9-32V) 99 +|**19**|**DIN8_VIN**|Discrete input 8 (signal detection with voltage 9-32V) 100 +|**20**|**DOUT1_OD**|Discrete output 1 “open drain” (60 V, 1A) 101 +|**22**|**DOUT2_OD**|Discrete output 2 “open drain” (60 V, 1A) 102 +|**23**|**DOUT3_OD**|Discrete output 3 “open drain” (60 V, 1A) 103 +|**24**|**DOUT4_OD**|Discrete output 4 “open drain” (60 V, 1A) 81 81 105 +Connection diagram of a discrete input to a dry contact output: 82 82 107 +(% aria-label="1732121887401-555.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121887401-555.png||data-xwiki-image-style-alignment="center" height="63" width="196"]](% title="Click and drag to resize" %)(%%)Connection diagram of a discrete input to an open collector output: 83 83 84 -=== X4,X5,X6, X7–header ofrelay1,2,3and4===109 +(% aria-label="1732122137116-973.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732122137116-973.png||data-xwiki-image-style-alignment="center" height="100" width="274"]](% title="Click and drag to resize" %)(%%)Connection diagram for a discrete input for detecting a 9-32V signal: 85 85 86 - ReceptacleHousing:Molex 39012020.Terminals: Molex5556111 +(% aria-label="1732121926812-202.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121926812-202.png||data-xwiki-image-style-alignment="center" height="76" width="242"]](% title="Click and drag to resize" %)(%%)Connection diagram for discrete output: 87 87 88 -[[image:173 2198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]]113 +[[image:1739361269041-663.png||data-xwiki-image-style-alignment="center" height="93" width="275"]] 89 89 115 +=== X4 – header for HVIL === 116 + 117 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 118 + 119 +[[image:1732122015188-642.png||data-xwiki-image-style-alignment="center" height="64" width="150"]] 120 + 90 90 |**Pin**|**Name**|**Description** 91 -|**1**|**V+**|Switching voltage (up to 55V, max 3A) 92 -|**2**|**NO**|Normally open contact 122 +|**1**|**-**|Not used 123 +|**2**|**HVIL_OUT**|Output of the current measurement circuit in the current loop (lower potential, measuring shunt output) 124 +|**3**|**HVIL_IN**|Input of the current measurement circuit in the current loop (higher potential, measuring shunt input) 125 +|**4**|**HVIL_PWR**|Current loop power supply (max 5V, 25mA) 93 93 94 - Contactor connectionexampleforallrelays:127 + If the BMS Main 3 / BMS Main 3X device generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main 3 / BMS Main 3X is a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins. 95 95 96 - [[image:1774456661980-866.png||data-xwiki-image-style-alignment="center"height="211"width="282"]]129 +Connection diagram to the current loop: 97 97 131 +[[image:1739361367866-742.png||data-xwiki-image-style-alignment="center" height="210" width="281"]] 98 98 99 -=== X 8– header for current sensor ===133 +=== X5 – header for current and temperature sensors === 100 100 135 +Receptacle Housing: Hirose ZE05-16DS-HU/R. Terminals: Hirose ZE05-2022SCF 136 + 137 +[[image:1733311958053-469.png||data-xwiki-image-style-alignment="center" height="83" width="349"]] 138 + 139 +(% style="width:539px" %) 140 +|**Pin**|**Name**|(% style="width:402px" %)**Description** 141 +|**1**|**CS1_5V**|(% style="width:402px" %)Current sensor 1 power line (5 V, max 50 mA) 142 +|**2–6**|**GND**|(% style="width:402px" %)Ground 143 +|**7**|**CS1_IN1**|(% style="width:402px" %)Current sensor 1 signal line (for a dual-range current sensor, High range output) 144 +|**8**|**CS1_REF_IN2**|(% style="width:402px" %)Current sensor 1 reference voltage signal line (for a dual-range current sensor, Low range output) 145 +|**9**|**CS2_5V**|(% style="width:402px" %)Current sensor 2 power line (5 V, max 50 mA) 146 +|**10**|**CS2_IN1**|(% style="width:402px" %)Current sensor 2 signal line (for a dual-range current sensor, High range output) 147 +|**11**|**CS2_REF_IN2**|(% style="width:402px" %)Current sensor 2 reference voltage signal line (for a dual-range current sensor, Low range output) 148 +|**12**|**CS3_5V**|(% style="width:402px" %)Current sensor 3 power line (5 V, max 50 mA) 149 +|**13**|**CS3_IN1**|(% style="width:402px" %)Current sensor 3 signal line (for a dual-range current sensor, High range output) 150 +|**14**|**CS3_REF_IN2**|(% style="width:402px" %)Current sensor 3 reference voltage signal line (for a dual-range current sensor, Low range output) 151 +|**15**|**TEMP1**|(% style="width:402px" %)Temperature sensor 1 signal line (NTC-thermistor 100 kOhm) 152 +|**16**|**TEMP2**|(% style="width:402px" %)Temperature sensor 2 signal line (NTC-thermistor 100 kOhm) 153 + 154 +Current sensor connection diagram (using the example of LEM HASS 100-S): 155 + 156 +[[image:1733316158040-285.png||data-xwiki-image-style-alignment="center" height="170" width="412"]] 157 + 158 +Current sensor connection diagram (using the example of LEM DHAB S/118): 159 + 160 +[[image:1733316170709-142.png||data-xwiki-image-style-alignment="center" height="171" width="413"]] 161 + 162 +NTC-thermistor connection diagram: 163 + 164 +[[image:1733316189878-329.png||data-xwiki-image-style-alignment="center" height="130" width="260"]] 165 + 166 +=== X6 – header for CAN1 and RS-485-1 (external buses) === 167 + 168 +Receptacle Housing: Hirose ZE05-5S-HU/R. Terminals: Hirose ZE05-2022SCF 169 + 170 +[[image:1733316218666-814.png||data-xwiki-image-style-alignment="center" height="55" width="162"]] 171 + 172 +|**Pin**|**Name**|**Description** 173 +|**1**|**CAN1_H**|CAN1 line H for communication with external equipment 174 +|**2**|**CAN1_L**|CAN1 line L for communication with external equipment 175 +|**3**|**CAN1_RS485_1_GND**|Ground of CAN1 and RS-485-1 176 +|**4**|**RS485_1_A**|RS-485-1 line A for communication with external equipment 177 +|**5**|**RS485_1_B**|RS-485-1 line B for communication with external equipment 178 + 179 +Connection diagram to the CAN1 bus: 180 + 181 +[[image:1733316241362-843.png||data-xwiki-image-style-alignment="center" height="153" width="410"]] 182 + 183 +Connection diagram to the RS-485-1 bus: 184 + 185 +[[image:1733316483336-290.png||data-xwiki-image-style-alignment="center" height="152" width="417"]] 186 + 187 +=== X7 – header for CAN2 (internal bus) === 188 + 101 101 Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 102 102 103 103 [[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 104 104 105 105 |**Pin**|**Name**|**Description** 194 +|**1**|**CAN2_H**|CAN2 line H for communication with other BMS devices 195 +|**2**|**CAN2_L**|CAN2 line L for communication with other BMS devices 196 +|**3**|**GND**|Ground 197 +|**4**|**CAN2_5V**|CAN2 power line (5 V, max 400 mA) 198 + 199 +Connection diagram to the CAN2 bus (using the example of connecting BMS Display 1.2): 200 + 201 +[[image:1733316563149-458.png||data-xwiki-image-style-alignment="center" height="158" width="392"]] 202 + 203 +=== X8 – header for CAN3 === 204 + 205 +Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF 206 + 207 +[[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]] 208 + 209 +|**Pin**|**Name**|**Description** 106 106 |**1**|**CAN3_H**|CAN3 line H 107 107 |**2**|**CAN3_L**|CAN3 line L 108 108 |**3**|**GND**|Ground ... ... @@ -142,8 +142,10 @@ 142 142 [[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="163" width="400"]] 143 143 ))) 144 144 145 -=== X10 – === 249 +=== X10 – miniUSB connector === 146 146 251 +The miniUSB connector is used to configure the parameters of the BMS Main 3 / BMS Main 3X device. 252 + 147 147 === X11 – header for high-voltage bus before contactors (plus) === 148 148 149 149 Receptacle Housing: Molex 436450200. Terminals: Molex 43030 ... ... @@ -234,7 +234,7 @@ 234 234 235 235 === J5, J6 – jumpers for emergency opening of contactors when removing discrete input signals DIN7, DIN8 === 236 236 237 -The BMS Main 2Rdevice implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed.343 +The BMS Main 3 / BMS Main 3X device implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed. 238 238 239 239 == Indicators == 240 240 ... ... @@ -288,5 +288,5 @@ 288 288 * Connect the high-voltage network integrity circuit (if necessary) to header X4. 289 289 * Connect external devices (if necessary) to header X6. 290 290 * Connect other devices (BMS Indication, BMS Display, if necessary) to header X7. 291 -* If the BMS Main 2Ris the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3.397 +* If the BMS Main 3 / BMS Main 3X is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3. 292 292 * Connect an external power supply to header X1. The device will start when there is a 9-32V power supply and one of the KEYRUN or CHARGE_ON signals with a voltage of more than 8.5V is supplied.
- 1731517180930-597.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -5.5 KB - Content
- 1731517188900-976.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -3.1 KB - Content
- 1731517195672-298.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -3.2 KB - Content
- 1732198827034-560.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.2 KB - Content
- 1732198890482-787.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -2.0 KB - Content
- 1732198896526-660.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.7 KB - Content
- 1732198937514-731.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -6.6 KB - Content
- 1741619814065-850.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -8.9 KB - Content
- 1741620022836-867.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -9.7 KB - Content
- 1774349658793-888.0b.STEP.JPG
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -42.2 KB - Content
- 1774453953377-602.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -7.8 KB - Content
- 1774455018488-627.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -35.6 KB - Content
- 1774456661980-866.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -13.9 KB - Content