... ... @@ -1,1 +1,1 @@ 1 - drafts.BMS Main2R.WebHome1 +Battery management systems.BMS Main 3.WebHome - Content
-
... ... @@ -3,11 +3,13 @@ 3 3 4 4 == Safety rules == 5 5 6 -To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, **at least one contactor**able to break the load and charge circuits must be connected to the BMS.6 +To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, at least one contactor able to break the load and charge circuits must be connected to the BMS. 7 7 8 -Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured.8 +Before use, configure the system. Proper operation of the BMS is possible only if it is correctly configured. 9 9 10 -(% class="box errormessage" %) 10 +It is not recommended to use the system in batteries formed by several series of cells connected in parallel. To increase capacity, it is recommended to connect several cells in parallel groups, and then connect the groups in series. 11 + 12 +(% class="box warningmessage" %) 11 11 ((( 12 12 The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery. 13 13 ))) ... ... @@ -14,29 +14,29 @@ 14 14 15 15 (% class="box errormessage" %) 16 16 ((( 17 -The system is not designed to operate with batteries whose total voltage exceeds 3000 V. 19 +**The system is not designed to operate with batteries whose total voltage exceeds 3000 V.** 18 18 ))) 19 19 20 20 == Installation procedure == 21 21 22 -The mounting location of the BMS Main 2Rdevice must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors.24 +The mounting location of the BMS Main 3 / BMS Main 3X device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors. 23 23 24 24 Overall and mounting dimensions are shown in figure below. 25 25 26 -[[image:17 74349658793-888.0b.STEP.JPG||data-xwiki-image-style-alignment="center" height="522" width="450"]](% title="Click and drag to resize" %)28 +(% data-widget="image" contenteditable="false" tabindex="-1" %)[[image:1733311711953-224.png||data-xwiki-image-style-alignment="center" height="566" width="775"]](% title="Click and drag to resize" %) 27 27 28 28 |**Parameter**|**Value** 29 -|Overall dimensions (length × width × height), mm| 120 × 120× 1630 -|Mounting dimensions (length × width), mm|1 14 × 11431 +|Overall dimensions (length × width × height), mm|200 × 123 × 12 32 +|Mounting dimensions (length × width), mm|194 × 114 31 31 |Mounting holes|M3 32 32 33 33 == Headers == 34 34 35 -The location and designation of connectors on the BMS Main 2Rdevice are shown below.37 +The location and designation of connectors on the BMS Main 3 / BMS Main 3X device are shown below. 36 36 37 37 (% contenteditable="false" tabindex="-1" %) 38 38 ((( 39 -[[image:17 74455018488-627.png||data-xwiki-image-style-alignment="center"]]41 +[[image:1732119505664-787.png||data-xwiki-image-style-alignment="center" height="417" width="684"]] 40 40 ))) 41 41 42 42 (% class="box warningmessage" %) ... ... @@ -45,43 +45,43 @@ 45 45 All headers are shown from the device side! 46 46 ))) 47 47 48 -=== X1 – header for discreteinputs and outputs===50 +=== X1 – header to power the device === 49 49 50 50 Receptacle Housing: Hirose ZE05-8DS-HU/R. Terminals: Hirose ZE05-2022SCF 51 51 52 52 (% class="wikigeneratedid" id="H" %) 53 -[[image:17321 98937514-731.png||data-xwiki-image-style-alignment="center" height="85" width="272"]]55 +(% data-widget="image" contenteditable="false" tabindex="-1" %)[[image:1732121673277-246.png||data-xwiki-image-style-alignment="center" height="85" width="200"]] 54 54 55 55 |**Pin**|**Name**|**Description** 56 -|**1–8**|**GND**|Ground 57 -|**9**|**DO_1**|Discrete output 1 (+5V, 20mA) 58 -|**10**|**DO_2**|Discrete output 2 (+5V, 20mA) 59 -|**11**|**DO_3**|Discrete output 3 (+5V, 20mA) 60 -|**12**|**DO_4**|Discrete output 4 (+5V, 20mA) 61 -|**13**|**DI_4**|Discrete input 4 (“dry contact”, +5V) 62 -|**14**|**DI_3**|Discrete input 3 (“dry contact”, +5V) 63 -|**15**|**DI_2**|Discrete input 2 (“dry contact”, +5V) 64 -|**16**|**DI_1**|Discrete input 1 (“dry contact”, +5V) 58 +|**1–2, 5–6**|**GND**|Ground 59 +|**3**|**KEYRUN**|Power-on signal 60 +|**4**|**CHARGE_ON**|Power-on signal (battery charge requirement) 61 +|**7–8**|**VIN**|Power line (9-32V) 65 65 63 +Power supply connection diagram: 66 66 65 +(% aria-label="1732120054870-496.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732120054870-496.png||data-xwiki-image-style-alignment="center" height="169" width="327"]] 67 67 68 -=== X2 – miniUSBconnector ===67 +=== X2 – header for contactors === 69 69 70 - TheminiUSBconnector is usedtoconfigurethe parametersof theBMSMain2R device.69 +Receptacle Housing: Hirose ZE05-12DS-HU/R. Terminals: Hirose ZE05-2022SCF 71 71 72 - ===(%title="Click anddragto resize"%)(%%)X3 – (% style="color:inherit;font-family:inherit; font-size:max(18px,min(20px,14.4444px+0.462963vw))"%)headerforpowersupply(%%)===71 +(% aria-label="1732121695049-411.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121695049-411.png||data-xwiki-image-style-alignment="center" height="87" width="267"]](% title="Click and drag to resize" %) 73 73 74 -Receptacle Housing: Molex 39012020. Terminals: Molex 5556 75 - 76 -[[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]] 77 - 78 78 |**Pin**|**Name**|**Description** 79 -|**1**|**GND**|Ground 80 -|**2**|**V+**|Supply voltage (9-32V) 74 +|**1–4, 8–9**|**GND**|Ground 75 +|**5**|**CONT1_OUT**|Contactor control 1 (plus) 76 +|**6**|**CONT2_OUT**|Contactor control 2 (plus) 77 +|**7**|**CONT3_OUT**|Contactor control 3 (plus) 78 +|**10**|**CONT4_OUT**|Contactor control 4 (plus) 79 +|**11**|**CONT5_OUT**|Contactor control 5 (plus) 80 +|**12**|**CONT6_OUT**|Contactor control 6 (plus) 81 81 82 + Contactor connection diagram: 82 82 84 +(% aria-label="1732121755886-234.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121755886-234.png||data-xwiki-image-style-alignment="center" height="82" width="260"]] 83 83 84 -=== X4,X5,X6,X7– ===86 +=== (% title="Click and drag to resize" %)(%%)X3 – header for discrete inputs and outputs === 85 85 86 86 Receptacle Housing: Hirose ZE05-24DS-HU/R. Terminals: Hirose ZE05-2022SCF 87 87 ... ... @@ -124,7 +124,7 @@ 124 124 |**3**|**HVIL_IN**|Input of the current measurement circuit in the current loop (higher potential, measuring shunt input) 125 125 |**4**|**HVIL_PWR**|Current loop power supply (max 5V, 25mA) 126 126 127 - If the BMS Main 2Rdevice generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main2Ris a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins.129 + If the BMS Main 3 / BMS Main 3X device generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main 3 / BMS Main 3X is a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins. 128 128 129 129 Connection diagram to the current loop: 130 130 ... ... @@ -246,8 +246,10 @@ 246 246 [[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="163" width="400"]] 247 247 ))) 248 248 249 -=== X10 – === 251 +=== X10 – miniUSB connector === 250 250 253 +The miniUSB connector is used to configure the parameters of the BMS Main 3 / BMS Main 3X device. 254 + 251 251 === X11 – header for high-voltage bus before contactors (plus) === 252 252 253 253 Receptacle Housing: Molex 436450200. Terminals: Molex 43030 ... ... @@ -338,7 +338,7 @@ 338 338 339 339 === J5, J6 – jumpers for emergency opening of contactors when removing discrete input signals DIN7, DIN8 === 340 340 341 -The BMS Main 2Rdevice implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed.345 +The BMS Main 3 / BMS Main 3X device implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed. 342 342 343 343 == Indicators == 344 344 ... ... @@ -392,5 +392,5 @@ 392 392 * Connect the high-voltage network integrity circuit (if necessary) to header X4. 393 393 * Connect external devices (if necessary) to header X6. 394 394 * Connect other devices (BMS Indication, BMS Display, if necessary) to header X7. 395 -* If the BMS Main 2Ris the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3.399 +* If the BMS Main 3 / BMS Main 3X is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3. 396 396 * Connect an external power supply to header X1. The device will start when there is a 9-32V power supply and one of the KEYRUN or CHARGE_ON signals with a voltage of more than 8.5V is supplied.
- 1731517180930-597.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -5.5 KB - Content
- 1731517188900-976.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -3.1 KB - Content
- 1731517195672-298.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -3.2 KB - Content
- 1732198827034-560.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.2 KB - Content
- 1732198890482-787.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -2.0 KB - Content
- 1732198896526-660.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.7 KB - Content
- 1732198937514-731.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -6.6 KB - Content
- 1741620022836-867.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -9.7 KB - Content
- 1774349658793-888.0b.STEP.JPG
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -42.2 KB - Content
- 1774453953377-602.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -7.8 KB - Content
- 1774455018488-627.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -35.6 KB - Content