... ... @@ -54,34 +54,35 @@
54 54  
55 55  |**Pin**|**Name**|**Description**
56 56  |**1–8**|**GND**|Ground
57 -|**9**|**DO_1**|Discrete output 1 (+5V, 20mA)
58 -|**10**|**DO_2**|Discrete output 2 (+5V, 20mA)
59 -|**11**|**DO_3**|Discrete output 3 (+5V, 20mA)
60 -|**12**|**DO_4**|Discrete output 4 (+5V, 20mA)
61 -|**13**|**DI_4**|Discrete input 4 (“dry contact”, +5V)
62 -|**14**|**DI_3**|Discrete input 3 (“dry contact”, +5V)
63 -|**15**|**DI_2**|Discrete input 2 (“dry contact”, +5V)
64 -|**16**|**DI_1**|Discrete input 1 (“dry contact”, +5V)
57 +| | |
58 +|**3**|**KEYRUN**|Power-on signal
59 +|**4**|**CHARGE_ON**|Power-on signal (battery charge requirement)
60 +|**7–8**|**VIN**|Power line (9-32V)
65 65  
62 +Power supply connection diagram:
66 66  
64 +(% aria-label="1732120054870-496.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732120054870-496.png||data-xwiki-image-style-alignment="center" height="169" width="327"]]
67 67  
68 -=== X2 – miniUSB connector ===
66 +=== X2 – header for contactors ===
69 69  
70 -The miniUSB connector is used to configure the parameters of the BMS Main 2R device.
68 +Receptacle Housing: Hirose ZE05-12DS-HU/R. Terminals: Hirose ZE05-2022SCF
71 71  
72 -=== (% title="Click and drag to resize" %)​(%%)X3 – (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)header for power supply(%%) ===
70 +(% aria-label="1732121695049-411.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121695049-411.png||data-xwiki-image-style-alignment="center" height="87" width="267"]](% title="Click and drag to resize" %)
73 73  
74 -Receptacle Housing: Molex 39012020. Terminals: Molex 5556
75 -
76 -[[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]]
77 -
78 78  |**Pin**|**Name**|**Description**
79 -|**1**|**GND**|Ground
80 -|**2**|**V+**|Supply voltage (9-32V)
73 +|**1–4, 8–9**|**GND**|Ground
74 +|**5**|**CONT1_OUT**|Contactor control 1 (plus)
75 +|**6**|**CONT2_OUT**|Contactor control 2 (plus)
76 +|**7**|**CONT3_OUT**|Contactor control 3 (plus)
77 +|**10**|**CONT4_OUT**|Contactor control 4 (plus)
78 +|**11**|**CONT5_OUT**|Contactor control 5 (plus)
79 +|**12**|**CONT6_OUT**|Contactor control 6 (plus)
81 81  
81 + Contactor connection diagram:
82 82  
83 +(% aria-label="1732121755886-234.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121755886-234.png||data-xwiki-image-style-alignment="center" height="82" width="260"]]
83 83  
84 -=== X4, X5, X6, X7 – ===
85 +=== (% title="Click and drag to resize" %)​(%%)X3header for discrete inputs and outputs ===
85 85  
86 86  Receptacle Housing: Hirose ZE05-24DS-HU/R. Terminals: Hirose ZE05-2022SCF
87 87  
... ... @@ -246,8 +246,10 @@
246 246  [[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="163" width="400"]]
247 247  )))
248 248  
249 -=== X10 – ===
250 +=== X10 – miniUSB connector ===
250 250  
252 +The miniUSB connector is used to configure the parameters of the BMS Main 2R device.
253 +
251 251  === X11 – header for high-voltage bus before contactors (plus) ===
252 252  
253 253  Receptacle Housing: Molex 436450200. Terminals: Molex 43030