... ... @@ -58,35 +58,30 @@
58 58  |**10**|**DO_2**|Discrete output 2 (+5V, 20mA)
59 59  |**11**|**DO_3**|Discrete output 3 (+5V, 20mA)
60 60  |**12**|**DO_4**|Discrete output 4 (+5V, 20mA)
61 -|**13**|**DI_4**|Discrete input 4 “dry contact” (+5V)
62 -|**14**|**DI_3**|Power-on signal
63 -|**15**|**DI_2**|Power-on signal (battery charge requirement)
64 -|**16**|**DI_1**|Power line (9-32V)
61 +|**13**|**DI_4**|Discrete input 4 (“dry contact”, +5V)
62 +|**14**|**DI_3**|Discrete input 3 (“dry contact”, +5V)
63 +|**15**|**DI_2**|Discrete input (“dry contact”, +5V)
64 +|**16**|**DI_1**|Discrete input (“dry contact”, +5V)
65 65  
66 -Power supply connection diagram:
67 67  
68 -(% aria-label="1732120054870-496.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732120054870-496.png||data-xwiki-image-style-alignment="center" height="169" width="327"]]
69 69  
70 -=== X2 – header for contactors ===
68 +=== X2 – miniUSB connector ===
71 71  
72 -Receptacle Housing: Hirose ZE05-12DS-HU/R. Terminals: Hirose ZE05-2022SCF
70 +The miniUSB connector is used to configure the parameters of the BMS Main 2R device.
73 73  
74 -(% aria-label="1732121695049-411.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121695049-411.png||data-xwiki-image-style-alignment="center" height="87" width="267"]](% title="Click and drag to resize" %)
72 +=== (% title="Click and drag to resize" %)​(%%)X3 – (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)header for power supply(%%) ===
75 75  
74 +Receptacle Housing: Molex 39012020. Terminals: Molex 5556
75 +
76 +[[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]]
77 +
76 76  |**Pin**|**Name**|**Description**
77 -|**1–4, 8–9**|**GND**|Ground
78 -|**5**|**CONT1_OUT**|Contactor control 1 (plus)
79 -|**6**|**CONT2_OUT**|Contactor control 2 (plus)
80 -|**7**|**CONT3_OUT**|Contactor control 3 (plus)
81 -|**10**|**CONT4_OUT**|Contactor control 4 (plus)
82 -|**11**|**CONT5_OUT**|Contactor control 5 (plus)
83 -|**12**|**CONT6_OUT**|Contactor control 6 (plus)
79 +|**1**|**GND**|Ground
80 +|**2**|**V+**|Supply voltage (9-32V)
84 84  
85 - Contactor connection diagram:
86 86  
87 -(% aria-label="1732121755886-234.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121755886-234.png||data-xwiki-image-style-alignment="center" height="82" width="260"]]
88 88  
89 -=== (% title="Click and drag to resize" %)​(%%)X3header for discrete inputs and outputs ===
84 +=== X4, X5, X6, X7 – ===
90 90  
91 91  Receptacle Housing: Hirose ZE05-24DS-HU/R. Terminals: Hirose ZE05-2022SCF
92 92  
... ... @@ -251,10 +251,8 @@
251 251  [[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="163" width="400"]]
252 252  )))
253 253  
254 -=== X10 – miniUSB connector ===
249 +=== X10 – ===
255 255  
256 -The miniUSB connector is used to configure the parameters of the BMS Main 2R device.
257 -
258 258  === X11 – header for high-voltage bus before contactors (plus) ===
259 259  
260 260  Receptacle Housing: Molex 436450200. Terminals: Molex 43030