Last modified by Admin on 2026/04/02 13:49

From version 81.2
edited by Admin
on 2026/03/25 16:31
Change comment: There is no comment for this version
To version 83.1
edited by Admin
on 2026/03/25 16:36
Change comment: Uploaded new attachment "1732198827034-560.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -54,35 +54,34 @@
54 54  
55 55  |**Pin**|**Name**|**Description**
56 56  |**1–8**|**GND**|Ground
57 -| | |
58 -|**3**|**KEYRUN**|Power-on signal
59 -|**4**|**CHARGE_ON**|Power-on signal (battery charge requirement)
60 -|**7–8**|**VIN**|Power line (9-32V)
57 +|**9**|**DO_1**|Discrete output 1 (+5V, 20mA)
58 +|**10**|**DO_2**|Discrete output 2 (+5V, 20mA)
59 +|**11**|**DO_3**|Discrete output 3 (+5V, 20mA)
60 +|**12**|**DO_4**|Discrete output 4 (+5V, 20mA)
61 +|**13**|**DI_4**|Discrete input 4 (“dry contact”, +5V)
62 +|**14**|**DI_3**|Discrete input 3 (“dry contact”, +5V)
63 +|**15**|**DI_2**|Discrete input 2 (“dry contact”, +5V)
64 +|**16**|**DI_1**|Discrete input 1 (“dry contact”, +5V)
61 61  
62 -Power supply connection diagram:
63 63  
64 -(% aria-label="1732120054870-496.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732120054870-496.png||data-xwiki-image-style-alignment="center" height="169" width="327"]]
65 65  
66 -=== X2 – header for contactors ===
68 +=== X2 – miniUSB connector ===
67 67  
68 -Receptacle Housing: Hirose ZE05-12DS-HU/R. Terminals: Hirose ZE05-2022SCF
70 +The miniUSB connector is used to configure the parameters of the BMS Main 2R device.
69 69  
70 -(% aria-label="1732121695049-411.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121695049-411.png||data-xwiki-image-style-alignment="center" height="87" width="267"]](% title="Click and drag to resize" %)
72 +=== (% title="Click and drag to resize" %)​(%%)X3 – (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)header for power supply(%%) ===
71 71  
74 +Receptacle Housing: Molex 39012020. Terminals: Molex 5556
75 +
76 +[[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]]
77 +
72 72  |**Pin**|**Name**|**Description**
73 -|**1–4, 8–9**|**GND**|Ground
74 -|**5**|**CONT1_OUT**|Contactor control 1 (plus)
75 -|**6**|**CONT2_OUT**|Contactor control 2 (plus)
76 -|**7**|**CONT3_OUT**|Contactor control 3 (plus)
77 -|**10**|**CONT4_OUT**|Contactor control 4 (plus)
78 -|**11**|**CONT5_OUT**|Contactor control 5 (plus)
79 -|**12**|**CONT6_OUT**|Contactor control 6 (plus)
79 +|**1**|**GND**|Ground
80 +|**2**|**V+**|Supply voltage (9-32V)
80 80  
81 - Contactor connection diagram:
82 82  
83 -(% aria-label="1732121755886-234.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121755886-234.png||data-xwiki-image-style-alignment="center" height="82" width="260"]]
84 84  
85 -=== (% title="Click and drag to resize" %)​(%%)X3header for discrete inputs and outputs ===
84 +=== X4, X5, X6, X7 – ===
86 86  
87 87  Receptacle Housing: Hirose ZE05-24DS-HU/R. Terminals: Hirose ZE05-2022SCF
88 88  
... ... @@ -247,10 +247,8 @@
247 247  [[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="163" width="400"]]
248 248  )))
249 249  
250 -=== X10 – miniUSB connector ===
249 +=== X10 – ===
251 251  
252 -The miniUSB connector is used to configure the parameters of the BMS Main 2R device.
253 -
254 254  === X11 – header for high-voltage bus before contactors (plus) ===
255 255  
256 256  Receptacle Housing: Molex 436450200. Terminals: Molex 43030