Changes for page 2. Installation and connection
Last modified by Admin on 2026/04/02 13:49
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (1 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -19,24 +19,24 @@ 19 19 20 20 == Installation procedure == 21 21 22 -The mounting location of the BMS Main 2Rdevice must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors.22 +The mounting location of the BMS Main 3 / BMS Main 3X device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors. 23 23 24 24 Overall and mounting dimensions are shown in figure below. 25 25 26 -[[image:17 74349658793-888.0b.STEP.JPG||data-xwiki-image-style-alignment="center" height="522" width="450"]](% title="Click and drag to resize" %)26 +(% data-widget="image" contenteditable="false" tabindex="-1" %)[[image:1733311711953-224.png||data-xwiki-image-style-alignment="center" height="566" width="775"]](% title="Click and drag to resize" %) 27 27 28 28 |**Parameter**|**Value** 29 -|Overall dimensions (length × width × height), mm| 120 × 120× 1630 -|Mounting dimensions (length × width), mm|1 14 × 11429 +|Overall dimensions (length × width × height), mm|200 × 123 × 12 30 +|Mounting dimensions (length × width), mm|194 × 114 31 31 |Mounting holes|M3 32 32 33 33 == Headers == 34 34 35 -The location and designation of connectors on the BMS Main 2Rdevice are shown below.35 +The location and designation of connectors on the BMS Main 3 / BMS Main 3X device are shown below. 36 36 37 37 (% contenteditable="false" tabindex="-1" %) 38 38 ((( 39 -[[image:17 74455018488-627.png||data-xwiki-image-style-alignment="center"]]39 +[[image:1732119505664-787.png||data-xwiki-image-style-alignment="center" height="417" width="684"]] 40 40 ))) 41 41 42 42 (% class="box warningmessage" %) ... ... @@ -45,16 +45,15 @@ 45 45 All headers are shown from the device side! 46 46 ))) 47 47 48 -=== X1 – header for discreteinputs and outputs===48 +=== X1 – header to power the device === 49 49 50 50 Receptacle Housing: Hirose ZE05-8DS-HU/R. Terminals: Hirose ZE05-2022SCF 51 51 52 52 (% class="wikigeneratedid" id="H" %) 53 -[[image:17321 98937514-731.png||data-xwiki-image-style-alignment="center" height="85" width="272"]]53 +(% data-widget="image" contenteditable="false" tabindex="-1" %)[[image:1732121673277-246.png||data-xwiki-image-style-alignment="center" height="85" width="200"]] 54 54 55 55 |**Pin**|**Name**|**Description** 56 -|**1–8**|**GND**|Ground 57 -| | | 56 +|**1–2, 5–6**|**GND**|Ground 58 58 |**3**|**KEYRUN**|Power-on signal 59 59 |**4**|**CHARGE_ON**|Power-on signal (battery charge requirement) 60 60 |**7–8**|**VIN**|Power line (9-32V) ... ... @@ -125,7 +125,7 @@ 125 125 |**3**|**HVIL_IN**|Input of the current measurement circuit in the current loop (higher potential, measuring shunt input) 126 126 |**4**|**HVIL_PWR**|Current loop power supply (max 5V, 25mA) 127 127 128 - If the BMS Main 2Rdevice generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main2Ris a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins.127 + If the BMS Main 3 / BMS Main 3X device generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main 3 / BMS Main 3X is a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins. 129 129 130 130 Connection diagram to the current loop: 131 131 ... ... @@ -249,7 +249,7 @@ 249 249 250 250 === X10 – miniUSB connector === 251 251 252 -The miniUSB connector is used to configure the parameters of the BMS Main 2Rdevice.251 +The miniUSB connector is used to configure the parameters of the BMS Main 3 / BMS Main 3X device. 253 253 254 254 === X11 – header for high-voltage bus before contactors (plus) === 255 255 ... ... @@ -341,7 +341,7 @@ 341 341 342 342 === J5, J6 – jumpers for emergency opening of contactors when removing discrete input signals DIN7, DIN8 === 343 343 344 -The BMS Main 2Rdevice implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed.343 +The BMS Main 3 / BMS Main 3X device implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed. 345 345 346 346 == Indicators == 347 347 ... ... @@ -395,5 +395,5 @@ 395 395 * Connect the high-voltage network integrity circuit (if necessary) to header X4. 396 396 * Connect external devices (if necessary) to header X6. 397 397 * Connect other devices (BMS Indication, BMS Display, if necessary) to header X7. 398 -* If the BMS Main 2Ris the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3.397 +* If the BMS Main 3 / BMS Main 3X is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3. 399 399 * Connect an external power supply to header X1. The device will start when there is a 9-32V power supply and one of the KEYRUN or CHARGE_ON signals with a voltage of more than 8.5V is supplied.
- 1774349658793-888.0b.STEP.JPG
-
- Size
-
... ... @@ -1,1 +1,1 @@ 1 - 42.2KB1 +123.9 KB - Content
- 1774455018488-627.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -35.6 KB - Content