... ... @@ -19,24 +19,24 @@
19 19  
20 20  == Installation procedure ==
21 21  
22 -The mounting location of the BMS Main 2R device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors.
22 +The mounting location of the BMS Main 3 / BMS Main 3X device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors.
23 23  
24 24  Overall and mounting dimensions are shown in figure below.
25 25  
26 -[[image:1774349658793-888.0b.STEP.JPG||data-xwiki-image-style-alignment="center" height="522" width="450"]](% title="Click and drag to resize" %)​
26 +(% data-widget="image" contenteditable="false" tabindex="-1" %)[[image:1733311711953-224.png||data-xwiki-image-style-alignment="center" height="566" width="775"]](% title="Click and drag to resize" %)​
27 27  
28 28  |**Parameter**|**Value**
29 -|Overall dimensions (length × width × height), mm|120 × 120 × 16
30 -|Mounting dimensions (length × width), mm|114 × 114
29 +|Overall dimensions (length × width × height), mm|200 × 123 × 12
30 +|Mounting dimensions (length × width), mm|194 × 114
31 31  |Mounting holes|M3
32 32  
33 33  == Headers ==
34 34  
35 -The location and designation of connectors on the BMS Main 2R device are shown below.
35 +The location and designation of connectors on the BMS Main 3 / BMS Main 3X device are shown below.
36 36  
37 37  (% contenteditable="false" tabindex="-1" %)
38 38  (((
39 -[[image:1774455018488-627.png||data-xwiki-image-style-alignment="center"]]
39 +[[image:1732119505664-787.png||data-xwiki-image-style-alignment="center" height="417" width="684"]]
40 40  )))
41 41  
42 42  (% class="box warningmessage" %)
... ... @@ -45,16 +45,15 @@
45 45  All headers are shown from the device side!
46 46  )))
47 47  
48 -=== X1 – header for discrete inputs and outputs ===
48 +=== X1 – header to power the device ===
49 49  
50 50  Receptacle Housing: Hirose ZE05-8DS-HU/R. Terminals: Hirose ZE05-2022SCF
51 51  
52 52  (% class="wikigeneratedid" id="H" %)
53 -[[image:1732198937514-731.png||data-xwiki-image-style-alignment="center" height="85" width="272"]]
53 +(% data-widget="image" contenteditable="false" tabindex="-1" %)[[image:1732121673277-246.png||data-xwiki-image-style-alignment="center" height="85" width="200"]]
54 54  
55 55  |**Pin**|**Name**|**Description**
56 -|**1–8**|**GND**|Ground
57 -| | |
56 +|**1–2, 5–6**|**GND**|Ground
58 58  |**3**|**KEYRUN**|Power-on signal
59 59  |**4**|**CHARGE_ON**|Power-on signal (battery charge requirement)
60 60  |**7–8**|**VIN**|Power line (9-32V)
... ... @@ -125,7 +125,7 @@
125 125  |**3**|**HVIL_IN**|Input of the current measurement circuit in the current loop (higher potential, measuring shunt input)
126 126  |**4**|**HVIL_PWR**|Current loop power supply (max 5V, 25mA)
127 127  
128 - If the BMS Main 2R device generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main 2R is a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins.
127 + If the BMS Main 3 / BMS Main 3X device generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main 3 / BMS Main 3X is a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins.
129 129  
130 130  Connection diagram to the current loop:
131 131  
... ... @@ -249,7 +249,7 @@
249 249  
250 250  === X10 – miniUSB connector ===
251 251  
252 -The miniUSB connector is used to configure the parameters of the BMS Main 2R device.
251 +The miniUSB connector is used to configure the parameters of the BMS Main 3 / BMS Main 3X device.
253 253  
254 254  === X11 – header for high-voltage bus before contactors (plus) ===
255 255  
... ... @@ -341,7 +341,7 @@
341 341  
342 342  === J5, J6 – jumpers for emergency opening of contactors when removing discrete input signals DIN7, DIN8 ===
343 343  
344 -The BMS Main 2R device implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed.
343 +The BMS Main 3 / BMS Main 3X device implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed.
345 345  
346 346  == Indicators ==
347 347  
... ... @@ -395,5 +395,5 @@
395 395  * Connect the high-voltage network integrity circuit (if necessary) to header X4.
396 396  * Connect external devices (if necessary) to header X6.
397 397  * Connect other devices (BMS Indication, BMS Display, if necessary) to header X7.
398 -* If the BMS Main 2R is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3.
397 +* If the BMS Main 3 / BMS Main 3X is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3.
399 399  * Connect an external power supply to header X1. The device will start when there is a 9-32V power supply and one of the KEYRUN or CHARGE_ON signals with a voltage of more than 8.5V is supplied.
1731517188900-976.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -3.1 KB
Content
1731517195672-298.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -3.2 KB
Content
1732198937514-731.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -6.6 KB
Content
1774349658793-888.0b.STEP.JPG
Size
... ... @@ -1,1 +1,1 @@