... ... @@ -19,24 +19,24 @@
19 19  
20 20  == Installation procedure ==
21 21  
22 -The mounting location of the BMS Main 3 / BMS Main 3X device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors.
22 +The mounting location of the BMS Main 2R device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors.
23 23  
24 24  Overall and mounting dimensions are shown in figure below.
25 25  
26 -(% data-widget="image" contenteditable="false" tabindex="-1" %)[[image:1733311711953-224.png||data-xwiki-image-style-alignment="center" height="566" width="775"]](% title="Click and drag to resize" %)​
26 +[[image:1774349658793-888.0b.STEP.JPG||data-xwiki-image-style-alignment="center" height="522" width="450"]](% title="Click and drag to resize" %)​
27 27  
28 28  |**Parameter**|**Value**
29 -|Overall dimensions (length × width × height), mm|200 × 123 × 12
30 -|Mounting dimensions (length × width), mm|194 × 114
29 +|Overall dimensions (length × width × height), mm|120 × 120 × 16
30 +|Mounting dimensions (length × width), mm|114 × 114
31 31  |Mounting holes|M3
32 32  
33 33  == Headers ==
34 34  
35 -The location and designation of connectors on the BMS Main 3 / BMS Main 3X device are shown below.
35 +The location and designation of connectors on the BMS Main 2R device are shown below.
36 36  
37 37  (% contenteditable="false" tabindex="-1" %)
38 38  (((
39 -[[image:1732119505664-787.png||data-xwiki-image-style-alignment="center" height="417" width="684"]]
39 +[[image:1774455018488-627.png||data-xwiki-image-style-alignment="center"]]
40 40  )))
41 41  
42 42  (% class="box warningmessage" %)
... ... @@ -45,354 +45,193 @@
45 45  All headers are shown from the device side!
46 46  )))
47 47  
48 -=== X1 – header to power the device ===
48 +=== X1 – header for discrete inputs and outputs ===
49 49  
50 50  Receptacle Housing: Hirose ZE05-8DS-HU/R. Terminals: Hirose ZE05-2022SCF
51 51  
52 52  (% class="wikigeneratedid" id="H" %)
53 -(% data-widget="image" contenteditable="false" tabindex="-1" %)[[image:1732121673277-246.png||data-xwiki-image-style-alignment="center" height="85" width="200"]]
53 +[[image:1732198937514-731.png||data-xwiki-image-style-alignment="center" height="85" width="272"]]
54 54  
55 55  |**Pin**|**Name**|**Description**
56 -|**1–2, 5–6**|**GND**|Ground
57 -|**3**|**KEYRUN**|Power-on signal
58 -|**4**|**CHARGE_ON**|Power-on signal (battery charge requirement)
59 -|**7–8**|**VIN**|Power line (9-32V)
56 +|**1–8**|**GND**|Ground
57 +|**9**|**DO_1**|Discrete output 1 (+5V, 20mA)
58 +|**10**|**DO_2**|Discrete output 2 (+5V, 20mA)
59 +|**11**|**DO_3**|Discrete output 3 (+5V, 20mA)
60 +|**12**|**DO_4**|Discrete output 4 (+5V, 20mA)
61 +|**13**|**DI_4**|Discrete input 4 (“dry contact”, +5V)
62 +|**14**|**DI_3**|Discrete input 3 (“dry contact”, +5V)
63 +|**15**|**DI_2**|Discrete input 2 (“dry contact”, +5V)
64 +|**16**|**DI_1**|Discrete input 1 (“dry contact”, +5V)
60 60  
61 -Power supply connection diagram:
62 62  
63 -(% aria-label="1732120054870-496.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732120054870-496.png||data-xwiki-image-style-alignment="center" height="169" width="327"]]
64 64  
65 -=== X2 – header for contactors ===
68 +=== X2 – miniUSB connector ===
66 66  
67 -Receptacle Housing: Hirose ZE05-12DS-HU/R. Terminals: Hirose ZE05-2022SCF
70 +The miniUSB connector is used to configure the parameters of the BMS Main 2R device.
68 68  
69 -(% aria-label="1732121695049-411.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121695049-411.png||data-xwiki-image-style-alignment="center" height="87" width="267"]](% title="Click and drag to resize" %)
72 +=== (% title="Click and drag to resize" %)​(%%)X3 – (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)header for power supply(%%) ===
70 70  
71 -|**Pin**|**Name**|**Description**
72 -|**1–4, 8–9**|**GND**|Ground
73 -|**5**|**CONT1_OUT**|Contactor control 1 (plus)
74 -|**6**|**CONT2_OUT**|Contactor control 2 (plus)
75 -|**7**|**CONT3_OUT**|Contactor control 3 (plus)
76 -|**10**|**CONT4_OUT**|Contactor control 4 (plus)
77 -|**11**|**CONT5_OUT**|Contactor control 5 (plus)
78 -|**12**|**CONT6_OUT**|Contactor control 6 (plus)
74 +Receptacle Housing: Molex 39012020. Terminals: Molex 5556
79 79  
80 - Contactor connection diagram:
76 +[[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]]
81 81  
82 -(% aria-label="1732121755886-234.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121755886-234.png||data-xwiki-image-style-alignment="center" height="82" width="260"]]
83 -
84 -=== (% title="Click and drag to resize" %)​(%%)X3 – header for discrete inputs and outputs ===
85 -
86 -Receptacle Housing: Hirose ZE05-24DS-HU/R. Terminals: Hirose ZE05-2022SCF
87 -
88 -(% aria-label="1732121811285-182.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121811285-182.png||data-xwiki-image-style-alignment="center" height="94" width="531"]]
89 -
90 90  |**Pin**|**Name**|**Description**
91 -|**1–8, 12, 16–17, 21**|**DIO_GND**|Ground of input and output signals
92 -|**9**|**DIN1_SIGNAL**|Discrete input 1 “dry contact”
93 -|**10**|**DIN2_SIGNAL**|Discrete input 2 “dry contact”
94 -|**11**|**DIN3_SIGNAL**|Discrete input 3 “dry contact”
95 -|**13**|**DIN4_SIGNAL**|Discrete input 4 “dry contact”
96 -|**14**|**DIN5_SIGNAL**|Discrete input 5 “dry contact”
97 -|**15**|**DIN6_SIGNAL**|Discrete input 6 “dry contact”
98 -|**18**|**DIN7_VIN**|Discrete input 7 (signal detection with voltage 9-32V)
99 -|**19**|**DIN8_VIN**|Discrete input 8 (signal detection with voltage 9-32V)
100 -|**20**|**DOUT1_OD**|Discrete output 1 “open drain” (60 V, 1A)
101 -|**22**|**DOUT2_OD**|Discrete output 2 “open drain” (60 V, 1A)
102 -|**23**|**DOUT3_OD**|Discrete output 3 “open drain” (60 V, 1A)
103 -|**24**|**DOUT4_OD**|Discrete output 4 “open drain” (60 V, 1A)
79 +|**1**|**GND**|Ground
80 +|**2**|**V+**|Supply voltage (9-32V)
104 104  
105 -Connection diagram of a discrete input to a dry contact output:
106 106  
107 -(% aria-label="1732121887401-555.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121887401-555.png||data-xwiki-image-style-alignment="center" height="63" width="196"]](% title="Click and drag to resize" %)​(%%)Connection diagram of a discrete input to an open collector output:
108 108  
109 -(% aria-label="1732122137116-973.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732122137116-973.png||data-xwiki-image-style-alignment="center" height="100" width="274"]](% title="Click and drag to resize" %)​(%%)Connection diagram for a discrete input for detecting a 9-32V signal:
84 +=== X4, X5, X6, X7 – header of relay 1, 2, 3 and 4 ===
110 110  
111 -(% aria-label="1732121926812-202.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732121926812-202.png||data-xwiki-image-style-alignment="center" height="76" width="242"]](% title="Click and drag to resize" %)​(%%)Connection diagram for discrete output:
86 +Receptacle Housing: Molex 39012020. Terminals: Molex 5556
112 112  
113 -[[image:1739361269041-663.png||data-xwiki-image-style-alignment="center" height="93" width="275"]]
88 +[[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]]
114 114  
115 -=== X4 – header for HVIL ===
116 -
117 -Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF
118 -
119 -[[image:1732122015188-642.png||data-xwiki-image-style-alignment="center" height="64" width="150"]]
120 -
121 121  |**Pin**|**Name**|**Description**
122 -|**1**|**-**|Not used
123 -|**2**|**HVIL_OUT**|Output of the current measurement circuit in the current loop (lower potential, measuring shunt output)
124 -|**3**|**HVIL_IN**|Input of the current measurement circuit in the current loop (higher potential, measuring shunt input)
125 -|**4**|**HVIL_PWR**|Current loop power supply (max 5V, 25mA)
91 +|**1**|**V+**|Switching voltage (up to 55V, max 3A)
92 +|**2**|**NO**|Normally open contact
126 126  
127 - If the BMS Main 3 / BMS Main 3X device generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main 3 / BMS Main 3X is a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins.
94 +Contactor connection example for all relays:
128 128  
129 -Connection diagram to the current loop:
96 +[[image:1774456661980-866.png||data-xwiki-image-style-alignment="center" height="211" width="282"]]
130 130  
131 -[[image:1739361367866-742.png||data-xwiki-image-style-alignment="center" height="210" width="281"]]
132 132  
133 -=== X5 – header for current and temperature sensors ===
99 +=== X8 – header for current sensor 1 ===
134 134  
135 -Receptacle Housing: Hirose ZE05-16DS-HU/R. Terminals: Hirose ZE05-2022SCF
101 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030
136 136  
137 -[[image:1733311958053-469.png||data-xwiki-image-style-alignment="center" height="83" width="349"]]
103 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]
138 138  
139 -(% style="width:539px" %)
140 -|**Pin**|**Name**|(% style="width:402px" %)**Description**
141 -|**1**|**CS1_5V**|(% style="width:402px" %)Current sensor 1 power line (5 V, max 50 mA)
142 -|**2–6**|**GND**|(% style="width:402px" %)Ground
143 -|**7**|**CS1_IN1**|(% style="width:402px" %)Current sensor 1 signal line (for a dual-range current sensor, High range output)
144 -|**8**|**CS1_REF_IN2**|(% style="width:402px" %)Current sensor 1 reference voltage signal line (for a dual-range current sensor, Low range output)
145 -|**9**|**CS2_5V**|(% style="width:402px" %)Current sensor 2 power line (5 V, max 50 mA)
146 -|**10**|**CS2_IN1**|(% style="width:402px" %)Current sensor 2 signal line (for a dual-range current sensor, High range output)
147 -|**11**|**CS2_REF_IN2**|(% style="width:402px" %)Current sensor 2 reference voltage signal line (for a dual-range current sensor, Low range output)
148 -|**12**|**CS3_5V**|(% style="width:402px" %)Current sensor 3 power line (5 V, max 50 mA)
149 -|**13**|**CS3_IN1**|(% style="width:402px" %)Current sensor 3 signal line (for a dual-range current sensor, High range output)
150 -|**14**|**CS3_REF_IN2**|(% style="width:402px" %)Current sensor 3 reference voltage signal line (for a dual-range current sensor, Low range output)
151 -|**15**|**TEMP1**|(% style="width:402px" %)Temperature sensor 1 signal line (NTC-thermistor 100 kOhm)
152 -|**16**|**TEMP2**|(% style="width:402px" %)Temperature sensor 2 signal line (NTC-thermistor 100 kOhm)
153 -
154 -Current sensor connection diagram (using the example of LEM HASS 100-S):
155 -
156 -[[image:1733316158040-285.png||data-xwiki-image-style-alignment="center" height="170" width="412"]]
157 -
158 -Current sensor connection diagram (using the example of LEM DHAB S/118):
159 -
160 -[[image:1733316170709-142.png||data-xwiki-image-style-alignment="center" height="171" width="413"]]
161 -
162 -NTC-thermistor connection diagram:
163 -
164 -[[image:1733316189878-329.png||data-xwiki-image-style-alignment="center" height="130" width="260"]]
165 -
166 -=== X6 – header for CAN1 and RS-485-1 (external buses) ===
167 -
168 -Receptacle Housing: Hirose ZE05-5S-HU/R. Terminals: Hirose ZE05-2022SCF
169 -
170 -[[image:1733316218666-814.png||data-xwiki-image-style-alignment="center" height="55" width="162"]]
171 -
172 172  |**Pin**|**Name**|**Description**
173 -|**1**|**CAN1_H**|CAN1 line H for communication with external equipment
174 -|**2**|**CAN1_L**|CAN1 line L for communication with external equipment
175 -|**3**|**CAN1_RS485_1_GND**|Ground of CAN1 and RS-485-1
176 -|**4**|**RS485_1_A**|RS-485-1 line A for communication with external equipment
177 -|**5**|**RS485_1_B**|RS-485-1 line B for communication with external equipment
106 +|**1**|**+5V**|Supply voltage for the current sensor 5V, max 50 mA
107 +|**2**|**GND**|Ground
108 +|**3**|**CS1_OUT**|Current sensor 1 output
109 +|**4**|**CS1_REF**|Current sensor 1 reference signal
178 178  
179 -Connection diagram to the CAN1 bus:
111 +=== X9 – (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)header for current sensor 2(%%) ===
180 180  
181 -[[image:1733316241362-843.png||data-xwiki-image-style-alignment="center" height="153" width="410"]]
113 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030
182 182  
183 -Connection diagram to the RS-485-1 bus:
115 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]
184 184  
185 -[[image:1733316483336-290.png||data-xwiki-image-style-alignment="center" height="152" width="417"]]
186 -
187 -=== X7 – header for CAN2 (internal bus) ===
188 -
189 -Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF
190 -
191 -[[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]]
192 -
193 193  |**Pin**|**Name**|**Description**
194 -|**1**|**CAN2_H**|CAN2 line H for communication with other BMS devices
195 -|**2**|**CAN2_L**|CAN2 line L for communication with other BMS devices
196 -|**3**|**GND**|Ground
197 -|**4**|**CAN2_5V**|CAN2 power line (5 V, max 400 mA)
118 +|**1**|**+5V**|Supply voltage for the current sensor 5V, max 50 mA
119 +|**2**|**GND**|Ground
120 +|**3**|**CS2_OUT**|Current sensor 2 output
121 +|**4**|**CS2_REF**|Current sensor 2 reference signal
198 198  
199 -Connection diagram to the CAN2 bus (using the example of connecting BMS Display 1.2):
123 +=== X10 – (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)header for temperature sensors(%%) ===
200 200  
201 -[[image:1733316563149-458.png||data-xwiki-image-style-alignment="center" height="158" width="392"]]
125 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030
202 202  
203 -=== X8 – header for CAN3 ===
127 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]
204 204  
205 -Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF
206 -
207 -[[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]]
208 -
209 209  |**Pin**|**Name**|**Description**
210 -|**1**|**CAN3_H**|CAN3 line H
211 -|**2**|**CAN3_L**|CAN3 line L
212 -|**3**|**GND**|Ground
213 -|**4**|**CAN3_5V**|CAN3 power line (5 V, max 400 mA)
130 +|**1, 2**|**GND**|Ground
131 +|**3**|**T_SENS1**|Temperature sensor 1 output
132 +|**4**|**T_SENS2**|Temperature sensor 2 output
214 214  
215 -(% class="box infomessage" %)
216 -(((
217 -**Note:**
218 -CAN3 operates differently depending on used firmware:
134 +=== X11 – (% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)header for BMS Logic(%%) ===
219 219  
220 -* **BMS Main 3:** CAN3 bus is reserved;
221 -* **BMS Main 3X:** CAN3 bus is used to connect with BMS Main 3 inside parallel strings. Diagram for connecting battery modules to the CAN3 bus:
136 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030
222 222  
223 -[[image:1733316622613-181.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="417"]]
224 -)))
138 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]
225 225  
226 -=== X9 – header for BMS Logic (RS-485-2) ===
227 -
228 -Receptacle Housing: Hirose ZE05-4S-HU/R. Terminals: Hirose ZE05-2022SCF
229 -
230 -[[image:1733316517741-698.png||data-xwiki-image-style-alignment="center" height="59" width="144"]]
231 -
232 232  |**Pin**|**Name**|**Description**
233 -|**1**|**LOGIC_B**|RS-485 line B for communication with BMS Logic
234 -|**2**|**LOGIC_A**|RS-485 line A for communication with BMS Logic
235 -|**3**|**GND**|Ground
236 -|**4**|**LOGIC_5V**|BMS Logic power line (+5V, max 400mA)
141 +|**1**|**LOGIC_A**|RS-485 line A for communication with BMS Logic
142 +|**2**|**LOGIC_B**|RS-485 line B for communication with BMS Logic
143 +|**3**|**LOGIC_5V**|Supply voltage for BMS Logic
144 +|**4**|**GND**|Ground
237 237  
238 -(% class="box infomessage" %)
239 -(((
240 -**Note:**
241 -RS-485-2 operates differently depending on used firmware:
146 +=== X12 – header for CAN2 interface ===
242 242  
243 -* **BMS Main 3X:** RS-485-2 bus is reserved;
244 -* **BMS Main 3:** RS-485-2 bus is used to connect with BMS Logics in a battery pack. Connection diagram for BMS Logic devices:
148 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030
245 245  
246 -[[image:1733316674363-604.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="163" width="400"]]
247 -)))
150 +[[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]
248 248  
249 -=== X10 – miniUSB connector ===
250 -
251 -The miniUSB connector is used to configure the parameters of the BMS Main 3 / BMS Main 3X device.
252 -
253 -=== X11 – header for high-voltage bus before contactors (plus) ===
254 -
255 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030
256 -
257 -[[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]]
258 -
259 259  |**Pin**|**Name**|**Description**
260 -|**1**|**IN1+**|Plus of the high-voltage bus (before contactors)
261 -|**2**|**IN1+**|Plus of the high-voltage bus (before contactors)
153 +|**1**|**CAN2_H**|CAN2 H line for communication with internal equipment
154 +|**2**|**CAN2_L**|CAN2 L line for communication with internal equipment
155 +|**3**|**–**|–
156 +|**4**|**GND**|Ground
262 262  
263 -(% class="box warningmessage" %)
264 -(((
265 -The connected voltage must not exceed 1000V.
266 -)))
158 +=== X13 – header for CAN1 and RS-485 interfaces ===
267 267  
268 -=== X12 – header for high-voltage bus before contactors (minus) ===
160 +Receptacle Housing: Molex 430250600. Terminals: Molex 43030
269 269  
270 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030
162 +[[image:https://docs.movicomelectric.com/bin/download/Battery%20management%20systems/BMS%20Main%202.1/2.%20Installation%20and%20connection/WebHome/1731517180930-597.png?width=113&height=81&rev=1.1||alt="1731517180930-597.png" data-xwiki-image-style-alignment="center" height="81" width="113"]]
271 271  
272 -[[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]]
273 -
274 274  |**Pin**|**Name**|**Description**
275 -|**1**|**IN1-**|Minus of the high-voltage bus (before contactors)
276 -|**2**|**IN1-**|Minus of the high-voltage bus (before contactors)
165 +|**1**|**RS485_1_A**|RS-485-1 line A for communication with external equipment
166 +|**2**|**CAN1_H**|CAN1 H line for communication with external equipment
167 +|**3**|**+5V**|Supply voltage 5V for external devices, max 200 mA
168 +|**4**|**RS485_1_B**|RS-485-1 line B for communication with external equipment
169 +|**5**|**CAN1_L**|CAN1 L line for communication with external equipment
170 +|**6**|**GND**|Ground
277 277  
278 -(% class="box warningmessage" %)
279 -(((
280 -The connected voltage must not exceed 1000V.
281 -)))
172 +=== J1 – jumper for switching CAN2 bus terminal resistor ===
282 282  
283 -=== X13 – header for high-voltage bus after contactors (plus) ===
284 284  
285 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030
175 +[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN2_H **and **CAN2_L **lines, install a jumper. The jumper is installed according to the table:
286 286  
287 -[[image:1733316780753-798.png||data-xwiki-image-style-alignment="center" height="60" width="91"]]
288 -
289 289  |**Pin**|**Name**|**Description**
290 -|**1**|**IN2+**|Plus of the high-voltage bus (after contactors)
291 -|**2**|**IN2+**|Plus of the high-voltage bus (after contactors)
178 +|**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN1 bus is connected
179 +|**2-3**|**-**|The 120 Ohm terminal resistor of the CAN1 bus is disconnected
292 292  
293 -(% class="box warningmessage" %)
294 -(((
295 -The connected voltage must not exceed 1000V.
296 -)))
181 +=== J2 – jumper for switching RS-485-1 bus terminal resistor ===
297 297  
298 -=== X14 – header for high-voltage bus after contactors (minus) ===
299 -
300 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030
301 -
302 -[[image:1733316843397-336.png||data-xwiki-image-style-alignment="center" height="53" width="79"]]
303 -
304 -|**Pin**|**Name**|**Description**
305 -|**1**|**IN2-**|Minus of the high-voltage bus (after contactors)
306 -|**2**|**IN2-**|Minus of the high-voltage bus (after contactors)
307 -
308 -(% class="box warningmessage" %)
309 -(((
310 -The connected voltage must not exceed 1000V.
311 -)))
312 -
313 -=== J1 – jumper for switching RS-485-1 bus terminal resistor ===
314 -
315 315  [[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]
316 316  
317 -To connect a terminal resistor between the **RS485_1_A** and **RS485_1_B** lines, install a jumper. The jumper is installed according to the table:
185 +To connect a terminal resistor between the **RS485_1_A **and **RS485_1_B **lines, install a jumper. The jumper is installed according to the table:
318 318  
319 319  |**Pin**|**Name**|**Description**
320 320  |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the RS-485-1 bus is connected
321 321  |**2-3**|**-**|The 120 Ohm terminal resistor of the RS-485-1 bus is disconnected
322 322  
323 -=== J2 – jumper for switching CAN1 bus terminal resistor ===
191 +=== J3 – jumper for switching CAN1 bus terminal resistor ===
324 324  
325 325  
326 -[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN1_H** and **CAN1_L** lines, install a jumper. The jumper is installed according to the table:
194 +[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN1_H **and **CAN1_L **lines, install a jumper. The jumper is installed according to the table:
327 327  
328 328  |**Pin**|**Name**|**Description**
329 329  |**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN1 bus is connected
330 330  |**2-3**|**-**|The 120 Ohm terminal resistor of the CAN1 bus is disconnected
331 331  
332 -=== J3 – jumper for switching CAN2 bus terminal resistor ===
333 -
334 -
335 -[[image:1733316982359-759.png||data-xwiki-image-style-alignment="center" height="77" width="148"]]To connect a terminal resistor between the **CAN2_H** and **CAN2_L** lines, install a jumper. The jumper is installed according to the table:
336 -
337 -|**Pin**|**Name**|**Description**
338 -|**1-2**|**120 Ohm**|The 120 Ohm terminal resistor of the CAN2 bus is connected
339 -|**2-3**|**-**|The 120 Ohm terminal resistor of the CAN2 bus is disconnected
340 -
341 -=== J5, J6 – jumpers for emergency opening of contactors when removing discrete input signals DIN7, DIN8 ===
342 -
343 -The BMS Main 3 / BMS Main 3X device implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed.
344 -
345 345  == Indicators ==
346 346  
347 -=== DS1LED indicating device power ===
202 +=== DS2operation indicator ===
348 348  
349 349  |**State**|**Description**
350 -|**Lights up green**|Device power (+5V) is present
351 -|**Doesn’t light up**|No device power
205 +|**Blinking green**|The BMS firmware is running
206 +|**Off**|The BMS firmware is not running
352 352  
353 -=== DS2LED indicating device work ===
208 +=== DS3communication indicator ===
354 354  
355 355  |**State**|**Description**
356 -|**Blinking green**|Executing the battery management program
357 -|**No blinking**|Program execution error
211 +|**Blinking yellow (2Hz)**|Initializing communication with BMS Logic boards
212 +|**Blinking yellow (25Hz)**|Communication with BMS Logic is established
358 358  
359 -=== DS3LED indicating interaction with child devices ===
214 +=== DS4error indicator ===
360 360  
361 -(% style="width:447px" %)
362 -|**State**|(% style="width:166px" %)**Description (Main 3)**|(% style="width:168px" %)**Description (Main 3X)**
363 -|**Blinking yellow**|(% style="width:166px" %)The device interacts with BMS Logic devices|(% style="width:168px" %)The device interacts with BMS Main 3 devices
364 -|**No blinking**|(% style="width:166px" %)-|(% style="width:168px" %)-
365 -
366 -=== DS4 – LED indicating loss of connection with child devices ===
367 -
368 -(% style="width:601px" %)
369 -|**State**|(% style="width:220px" %)**Description (Main 3)**|(% style="width:218px" %)**Description (Main 3X)**
370 -|**Blinking/lights up red**|(% style="width:220px" %)Communication with one or more BMS Logic devices is lost|(% style="width:218px" %)Communication with one or more BMS Main 3 devices is lost
371 -|**No blinking**|(% style="width:220px" %)Communication with BMS Logic devices is stable|(% style="width:218px" %)Communication with BMS Main 3 devices is stable
372 -
373 -=== DS5-DS10 – LEDs indicating contactor switches 1-6 ===
374 -
375 375  |**State**|**Description**
376 -|**Lights up green**|The switch supplies voltage to the contactor winding
377 -|**Doesn’t light up**|The switch doesn’t supply voltage to the contactor winding
217 +|**Blinking red**|Errors in communication with BMS Logic
378 378  
379 -=== DS11 – LED indicating the presence of power supply for contactors ===
219 +=== DS1.1-DS1.4 – relay 1-4 indicator ===
380 380  
381 381  |**State**|**Description**
382 -|**Lights up green**|Power supply for contactor switches (9-32V) is present
383 -|**Doesn’t light up**|Power supply for contactor switches (9-32V) is not present
222 +|**Lights green**|Relay #1-#4 is closed
223 +|**Off**|Relay #1-#4 is opened
384 384  
385 385  == Connection procedure ==
386 386  
387 387  All operations to connect the device must be carried out with the supply voltage removed.
388 388  
389 -* Connect the power contactors to header X2.
390 -* Connect one or more current sensors, as well as external temperature sensors (if necessary) to header X5.
391 -* Connect BMS Logic devices to header X9.
392 -* Connect digital inputs and outputs (if necessary) to header X3.
393 -* Connect the high voltage bus (if necessary) to headers X11-X14.
394 -* Connect the high-voltage network integrity circuit (if necessary) to header X4.
395 -* Connect external devices (if necessary) to header X6.
396 -* Connect other devices (BMS Indication, BMS Display, if necessary) to header X7.
397 -* If the BMS Main 3 / BMS Main 3X is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3.
398 -* Connect an external power supply to header X1. The device will start when there is a 9-32V power supply and one of the KEYRUN or CHARGE_ON signals with a voltage of more than 8.5V is supplied.
229 +* Connect the power contactors to headers X4-X7.
230 +* Connect one or more current sensors to headers X8 and X9.
231 +* Connect external temperature sensors (if necessary) to header X10.
232 +* Connect BMS Logic devices to header X11.
233 +* Connect digital inputs and outputs (if necessary) to header X1.
234 +* Connect external devices (if necessary) to header X13.
235 +* Connect other devices (BMS Indication, BMS Display, if necessary) to header X12.
236 +* If the BMS Main 2R is the last device on the CAN2,  RS-485-1 or CAN1 bus, install jumpers J1-J3.
237 +* Connect an external power supply to header X3. The device will start when there is a 9-32V power supply.
1774349658793-888.0b.STEP.JPG
Size
... ... @@ -1,1 +1,1 @@
1 -123.9 KB
1 +42.2 KB
Content
1741619814065-850.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +8.9 KB
Content
1774453953377-602.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +7.8 KB
Content
1774455018488-627.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +35.6 KB
Content
1774456661980-866.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +13.9 KB
Content