Changes for page 2. Installation and connection
Last modified by Admin on 2026/04/02 13:49
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 11 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - Battery managementsystems.BMS Main3.WebHome1 +drafts.BMS Main 2R.WebHome - Content
-
... ... @@ -3,13 +3,11 @@ 3 3 4 4 == Safety rules == 5 5 6 -To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, at least one contactor able to break the load and charge circuits must be connected to the BMS. 6 +To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, **at least one contactor** able to break the load and charge circuits must be connected to the BMS. 7 7 8 8 Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured. 9 9 10 -It is not recommended to use the system in batteries formed by several series of cells connected in parallel. To increase capacity, it is recommended to connect several cells in parallel groups, and then connect the groups in series. 11 - 12 -(% class="box warningmessage" %) 10 +(% class="box errormessage" %) 13 13 ((( 14 14 The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery. 15 15 ))) ... ... @@ -16,29 +16,29 @@ 16 16 17 17 (% class="box errormessage" %) 18 18 ((( 19 - **The system is not designed to operate with batteries whose total voltage exceeds 3000 V.**17 +The system is not designed to operate with batteries whose total voltage exceeds 3000 V. 20 20 ))) 21 21 22 22 == Installation procedure == 23 23 24 -The mounting location of the BMS Main 3/ BMS Main 3Xdevice must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors.22 +The mounting location of the BMS Main 2R device must be protected from mechanical particles (dust, dirt, large objects) and water. The installation location must provide easy access for subsequent connection to the device connectors. 25 25 26 26 Overall and mounting dimensions are shown in figure below. 27 27 28 - (% data-widget="image" contenteditable="false" tabindex="-1" %)[[image:1733311711953-224.png||data-xwiki-image-style-alignment="center" height="566" width="775"]](% title="Click and drag to resize" %)26 +[[image:1774349658793-888.0b.STEP.JPG||data-xwiki-image-style-alignment="center" height="522" width="450"]](% title="Click and drag to resize" %) 29 29 30 30 |**Parameter**|**Value** 31 -|Overall dimensions (length × width × height), mm|20 0× 123× 1232 -|Mounting dimensions (length × width), mm|1 94 × 11429 +|Overall dimensions (length × width × height), mm|120 × 120 × 16 30 +|Mounting dimensions (length × width), mm|114 × 114 33 33 |Mounting holes|M3 34 34 35 35 == Headers == 36 36 37 -The location and designation of connectors on the BMS Main 3/ BMS Main 3Xdevice are shown below.35 +The location and designation of connectors on the BMS Main 2R device are shown below. 38 38 39 39 (% contenteditable="false" tabindex="-1" %) 40 40 ((( 41 -[[image:17 32119505664-787.png||data-xwiki-image-style-alignment="center"height="417" width="684"]]39 +[[image:1774455018488-627.png||data-xwiki-image-style-alignment="center"]] 42 42 ))) 43 43 44 44 (% class="box warningmessage" %) ... ... @@ -47,37 +47,37 @@ 47 47 All headers are shown from the device side! 48 48 ))) 49 49 50 -=== X1 – header topowerthedevice ===48 +=== X1 – header for discrete inputs and outputs === 51 51 52 52 Receptacle Housing: Hirose ZE05-8DS-HU/R. Terminals: Hirose ZE05-2022SCF 53 53 54 54 (% class="wikigeneratedid" id="H" %) 55 - (% data-widget="image" contenteditable="false" tabindex="-1" %)[[image:1732121673277-246.png||data-xwiki-image-style-alignment="center" height="85" width="200"]]53 +[[image:1732198937514-731.png||data-xwiki-image-style-alignment="center" height="85" width="272"]] 56 56 57 57 |**Pin**|**Name**|**Description** 58 -|**1–2, 5–6**|**GND**|Ground 59 -|**3**|**KEYRUN**|Power-on signal 60 -|**4**|**CHARGE_ON**|Power-on signal (battery charge requirement) 61 -|**7–8**|**VIN**|Power line (9-32V) 56 +|**1–8**|**GND**|Ground 57 +|**9**|**DO_1**|Discrete output 1 (+5V, 20mA) 58 +|**10**|**DO_2**|Discrete output 2 (+5V, 20mA) 59 +|**11**|**DO_3**|Discrete output 3 (+5V, 20mA) 60 +|**12**|**DO_4**|Discrete output 4 (+5V, 20mA) 61 +|**13**|**DI_4**|Discrete input 4 (“dry contact”, +5V) 62 +|**14**|**DI_3**|Discrete input 3 (“dry contact”, +5V) 63 +|**15**|**DI_2**|Discrete input 2 (“dry contact”, +5V) 64 +|**16**|**DI_1**|Discrete input 1 (“dry contact”, +5V) 62 62 63 -Power supply connection diagram: 64 64 65 -(% aria-label="1732120054870-496.png image widget" data-widget="image" contenteditable="false" role="region" tabindex="-1" %)[[image:1732120054870-496.png||data-xwiki-image-style-alignment="center" height="169" width="327"]] 66 66 67 -=== X2 – header for contactors===68 +=== X2 – === 68 68 69 - ReceptacleHousing: HiroseZE05-12DS-HU/R. Terminals:HiroseZE05-2022SCF70 +=== P1 – header for power supply === 70 70 71 - (% aria-label="1732121695049-411.png image widget" data-widget="image"contenteditable="false"role="region"tabindex="-1"%)[[image:1732121695049-411.png||data-xwiki-image-style-alignment="center"height="87" width="267"]](% title="Click and drag toresize"%)72 +Receptacle Housing: Molex 39012020. Terminals: Molex 5556 72 72 74 +[[image:https://docs.movicomelectric.com/bin/download/Battery%20management%20systems/BMS%20Main%202.1/2.%20Installation%20and%20connection/WebHome/1732198827034-560.png?width=41&height=78&rev=1.1||alt="1732198827034-560.png" height="78" width="41"]] 75 + 73 73 |**Pin**|**Name**|**Description** 74 -|**1–4, 8–9**|**GND**|Ground 75 -|**5**|**CONT1_OUT**|Contactor control 1 (plus) 76 -|**6**|**CONT2_OUT**|Contactor control 2 (plus) 77 -|**7**|**CONT3_OUT**|Contactor control 3 (plus) 78 -|**10**|**CONT4_OUT**|Contactor control 4 (plus) 79 -|**11**|**CONT5_OUT**|Contactor control 5 (plus) 80 -|**12**|**CONT6_OUT**|Contactor control 6 (plus) 77 +|**1**|**GND**|Ground 78 +|**2**|**V+**|Supply voltage 9-30V 81 81 82 82 Contactor connection diagram: 83 83 ... ... @@ -126,7 +126,7 @@ 126 126 |**3**|**HVIL_IN**|Input of the current measurement circuit in the current loop (higher potential, measuring shunt input) 127 127 |**4**|**HVIL_PWR**|Current loop power supply (max 5V, 25mA) 128 128 129 - If the BMS Main 3/ BMS Main 3Xdevice generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main3 / BMS Main 3Xis a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins.127 + If the BMS Main 2R device generates current in a current loop, the current loop must be connected to the **HVIL_PWR** and **HVIL_IN** pins. If BMS Main 2R is a passive current loop meter, then the current loop must be connected to the **HVIL_IN** and **HVIL_OUT** pins. 130 130 131 131 Connection diagram to the current loop: 132 132 ... ... @@ -250,7 +250,7 @@ 250 250 251 251 === X10 – miniUSB connector === 252 252 253 -The miniUSB connector is used to configure the parameters of the BMS Main 3/ BMS Main 3Xdevice.251 +The miniUSB connector is used to configure the parameters of the BMS Main 2R device. 254 254 255 255 === X11 – header for high-voltage bus before contactors (plus) === 256 256 ... ... @@ -342,7 +342,7 @@ 342 342 343 343 === J5, J6 – jumpers for emergency opening of contactors when removing discrete input signals DIN7, DIN8 === 344 344 345 -The BMS Main 3/ BMS Main 3Xdevice implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed.343 +The BMS Main 2R device implements a circuit for hardware opening of power contactors when the discrete input signal DIN7 and/or DIN8 (voltage level 9-32V) is removed. To enable this function, jumper J5 and/or J6 must be installed. 346 346 347 347 == Indicators == 348 348 ... ... @@ -396,5 +396,5 @@ 396 396 * Connect the high-voltage network integrity circuit (if necessary) to header X4. 397 397 * Connect external devices (if necessary) to header X6. 398 398 * Connect other devices (BMS Indication, BMS Display, if necessary) to header X7. 399 -* If the BMS Main 3/ BMS Main 3X is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3.397 +* If the BMS Main 2R is the last device on the RS-485-1, CAN1, or CAN2 bus, install jumpers J1-J3. 400 400 * Connect an external power supply to header X1. The device will start when there is a 9-32V power supply and one of the KEYRUN or CHARGE_ON signals with a voltage of more than 8.5V is supplied.
- 1731517180930-597.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +5.5 KB - Content
- 1731517188900-976.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +3.1 KB - Content
- 1731517195672-298.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +3.2 KB - Content
- 1732198827034-560.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.2 KB - Content
- 1732198890482-787.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +2.0 KB - Content
- 1732198896526-660.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.7 KB - Content
- 1732198937514-731.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +6.6 KB - Content
- 1741620022836-867.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.7 KB - Content
- 1774349658793-888.0b.STEP.JPG
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +42.2 KB - Content
- 1774453953377-602.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.8 KB - Content
- 1774455018488-627.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +35.6 KB - Content