... ... @@ -240,7 +240,11 @@
240 240  
241 241  bit 25 – “Power up”;
242 242  
243 -bits 26-31 – reserved.
243 +bit 26 — signal “External 1”;
244 +
245 +bit 27 — signal “Heater (AUX)”;
246 +
247 +bits 28-31 — not used.
244 244  )))|(% style="width:96px" %)U32
245 245  |(% style="width:92px" %)**0x200B**|(% style="width:94px" %)1|(% style="width:368px" %)(((
246 246  Discrete output signals (bitfield):