Changes for page 5.2 Modbus protocol

Last modified by Admin on 2026/04/24 10:30

From version 8.2
edited by Admin
on 2025/02/04 10:03
Change comment: There is no comment for this version
To version 11.1
edited by Admin
on 2025/02/04 10:15
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -240,7 +240,11 @@
240 240  
241 241  bit 25 – “Power up”;
242 242  
243 -bits 26-31 – reserved.
243 +bit 26 — signal “External 1”;
244 +
245 +bit 27 — signal “Heater (AUX)”;
246 +
247 +bits 28-31 — not used.
244 244  )))|(% style="width:96px" %)U32
245 245  |(% style="width:92px" %)**0x200B**|(% style="width:94px" %)1|(% style="width:368px" %)(((
246 246  Discrete output signals (bitfield):
... ... @@ -299,7 +299,15 @@
299 299  
300 300  bit 13 – “General error”;
301 301  
302 -bits 14-31 — reserved.
306 +bit 14 — reserved (set to 0);
307 +
308 +bit 15 — reserved (set to 0);
309 +
310 +bit 16 — reserved (set to 0);
311 +
312 +bit 17 — “Precharge error”;
313 +
314 +bits 18-31 — not used.
303 303  )))|(% style="width:96px" %)U32
304 304  |(% style="width:92px" %)**0x2010**|(% style="width:94px" %)1|(% style="width:368px" %)Address or the BMS Logic device whose parameters are in registers 0x2011-0x20C9|(% style="width:96px" %)U16
305 305  |(% style="width:92px" %)**0x2011**|(% style="width:94px" %)1|(% style="width:368px" %)(((