Changes for page 5.2 Modbus protocol
Last modified by Admin on 2026/04/24 10:30
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -323,7 +323,7 @@ 323 323 324 324 bit 2 — device is ready; 325 325 326 -bit 3 — data from thedeviceis actual;326 +bit 3 — reserved; 327 327 328 328 bit 4 — temperature sensor #1 is present; 329 329 ... ... @@ -467,12 +467,12 @@ 467 467 bits 26-31 — seconds. 468 468 )))|(% style="width:96px" %)U32[2] 469 469 |(% style="width:92px" %)**0x2204-0x2207**|(% style="width:94px" %)4|(% style="width:368px" %)Record #2 from the errors journal|(% style="width:96px" %)U32[2] 470 -|(% style="width:92px" %)**0x2208-0x227B**|(% style="width:94px" %) 116|(% style="width:368px" %)Records #3-31 from the errors journal|(% style="width:96px" %)470 +|(% style="width:92px" %)**0x2208-0x227B**|(% style="width:94px" %) |(% style="width:368px" %)Records #3-31 from the errors journal|(% style="width:96px" %) 471 471 |(% style="width:92px" %)**0x227C-0x227F**|(% style="width:94px" %)4|(% style="width:368px" %)Record #32 from the errors journal|(% style="width:96px" %)U32[2] 472 472 |(% style="width:92px" %)**0x2300**|(% style="width:94px" %)1|(% style="width:368px" %)Number of the last record from the errors journal (1..32)|(% style="width:96px" %)U16 473 473 |(% style="width:92px" %)**0x2380-0x2383**|(% style="width:94px" %)4|(% style="width:368px" %)Record data #1 from the errors journal. First 32-bit word contains errors 2 flags (see 0x200E-0x200F).|(% style="width:96px" %)U32[2] 474 474 |(% style="width:92px" %)**0x2384-0x2387**|(% style="width:94px" %)4|(% style="width:368px" %)Record data #2 from the errors journal|(% style="width:96px" %)U32[2] 475 -|(% style="width:92px" %)**0x2388-0x23FB**|(% style="width:94px" %) 116|(% style="width:368px" %)Records data #3-31 from the errors journal|(% style="width:96px" %)475 +|(% style="width:92px" %)**0x2388-0x23FB**|(% style="width:94px" %) |(% style="width:368px" %)Records data #3-31 from the errors journal|(% style="width:96px" %) 476 476 |(% style="width:92px" %)**0x23FC-0x23FF**|(% style="width:94px" %)4|(% style="width:368px" %)Record data #32 from the errors journal|(% style="width:96px" %)U32[2] 477 477 |(% style="width:92px" %)**0x2400-0x2401**|(% style="width:94px" %)2|(% style="width:368px" %)Current measured by the auxiliary current sensor, A|(% style="width:96px" %)REAL32 478 478 |(% style="width:92px" %)**0x2402-0x2403**|(% style="width:94px" %)2|(% style="width:368px" %)((( ... ... @@ -680,3 +680,39 @@ 680 680 681 681 2-65535 – use the physical input "Fuse 3". 682 682 )))|(% style="width:96px" %)U16 683 +|(% style="width:92px" %)**0x5112**|(% style="width:94px" %)1|(% style="width:368px" %)((( 684 +Software control of the "Circuit breaker status" signal. Allowable values: 685 + 686 +0 – clear the signal; 687 + 688 +1 – set the signal; 689 + 690 +2-65535 – use the physical input "Circuit breaker status". 691 +)))|(% style="width:96px" %)U16 692 +|(% style="width:92px" %)**0x5113**|(% style="width:94px" %)1|(% style="width:368px" %)((( 693 +Software control of the "Balancing request" signal. Allowable values: 694 + 695 +0 – clear the signal; 696 + 697 +1 – set the signal; 698 + 699 +2-65535 – use the physical input "Balancing request". 700 +)))|(% style="width:96px" %)U16 701 +|(% style="width:92px" %)**0x5114**|(% style="width:94px" %)1|(% style="width:368px" %)((( 702 +Software control of the "Close Main contactor" signal. Allowable values: 703 + 704 +0 – clear the signal; 705 + 706 +1 – set the signal; 707 + 708 +2-65535 – use the physical input "Close Main contactor". 709 +)))|(% style="width:96px" %)U16 710 +|(% style="width:92px" %)**0x5115**|(% style="width:94px" %)1|(% style="width:368px" %)((( 711 +Software control of the "Close External 1" signal. Allowable values: 712 + 713 +0 – clear the signal; 714 + 715 +1 – set the signal; 716 + 717 +2-65535 – use the physical input "Close External 1". 718 +)))|(% style="width:96px" %)U16