Changes for page 5.2 Modbus protocol
Last modified by Admin on 2026/04/24 10:30
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -240,11 +240,7 @@ 240 240 241 241 bit 25 – “Power up”; 242 242 243 -bit 26 — signal “External 1”; 244 - 245 -bit 27 — signal “Heater (AUX)”; 246 - 247 -bits 28-31 — not used. 243 +bits 26-31 – reserved. 248 248 )))|(% style="width:96px" %)U32 249 249 |(% style="width:92px" %)**0x200B**|(% style="width:94px" %)1|(% style="width:368px" %)((( 250 250 Discrete output signals (bitfield): ... ... @@ -272,7 +272,7 @@ 272 272 273 273 bits 4-15 — not used. 274 274 )))|(% style="width:96px" %)U16 275 -|(% style="width:92px" %)**0x200E -0x200F**|(% style="width:94px" %)2|(% style="width:368px" %)(((271 +|(% style="width:92px" %)**0x200E**|(% style="width:94px" %)2|(% style="width:368px" %)((( 276 276 Errors 2 (bitfield): 277 277 278 278 bit 0 – "Low CH temperature", temperature is too low for charging; ... ... @@ -303,15 +303,7 @@ 303 303 304 304 bit 13 – “General error”; 305 305 306 -bit 14 — reserved (set to 0); 307 - 308 -bit 15 — reserved (set to 0); 309 - 310 -bit 16 — reserved (set to 0); 311 - 312 -bit 17 — “Precharge error”; 313 - 314 -bits 18-31 — not used. 302 +bits 14-31 — reserved. 315 315 )))|(% style="width:96px" %)U32 316 316 |(% style="width:92px" %)**0x2010**|(% style="width:94px" %)1|(% style="width:368px" %)Address or the BMS Logic device whose parameters are in registers 0x2011-0x20C9|(% style="width:96px" %)U16 317 317 |(% style="width:92px" %)**0x2011**|(% style="width:94px" %)1|(% style="width:368px" %)((( ... ... @@ -365,19 +365,13 @@ 365 365 |(% style="width:92px" %)**0x20F4**|(% style="width:94px" %)1|(% style="width:368px" %)((( 366 366 Discrete input signals 2 (bitfield): 367 367 368 -bit 0 —“Fuse 2”;356 +bit 0 – “Fuse 2”; 369 369 370 -bit 1 —“Fuse 3”;358 +bit 1 – “Fuse 3”; 371 371 372 -bit 2 —“Circuit breaker status”;360 +bit 2 – “Circuit breaker status”; 373 373 374 -bit 3 — signal "Balancing request"; 375 - 376 -bit 4 — signal "Close Main contactor"; 377 - 378 -bit 5 — signal "Close External 1"; 379 - 380 -bits 6-15 — not used. 362 +bits 3-15 – reserved. 381 381 )))|(% style="width:96px" %)U16 382 382 |(% style="width:92px" %)**0x2100-0x2101**|(% style="width:94px" %)2|(% style="width:368px" %)Battery state of charge (SOC), %|(% style="width:96px" %)REAL32 383 383 |(% style="width:92px" %)**0x2102**|(% style="width:94px" %)1|(% style="width:368px" %)Number of BMS Logic devices|(% style="width:96px" %)U16