Changes for page 5.2 Modbus protocol
Last modified by Admin on 2026/04/24 10:30
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -440,15 +440,15 @@ 440 440 |(% style="width:92px" %)**0x2181-0x2182**|(% style="width:94px" %)2|(% style="width:368px" %)Ethernet netmask|(% style="width:96px" %)U8[4] 441 441 |(% style="width:92px" %)**0x2183-0x2184**|(% style="width:94px" %)2|(% style="width:368px" %)Ethernet gateway|(% style="width:96px" %)U8[4] 442 442 |(% style="width:92px" %)**0x2185-0x2186**|(% style="width:94px" %)2|(% style="width:368px" %)Calibrated voltage in the reference line of the current sensor, V|(% style="width:96px" %)REAL32 443 -|(% style="width:92px" %)**0x218E**|(% style="width:94px" %)2|(% style="width:368px" %)Voltage from the current sensor, V|(% style="width:96px" %)REAL32 444 -|(% style="width:92px" %)**0x2190**|(% style="width:94px" %)2|(% style="width:368px" %)Voltage in the reference line of the current sensor, V|(% style="width:96px" %)REAL32 445 -|(% style="width:92px" %)**0x2192**|(% style="width:94px" %)2|(% style="width:368px" %)Voltage from the auxiliary current sensor, V|(% style="width:96px" %)REAL32 446 -|(% style="width:92px" %)**0x2194**|(% style="width:94px" %)2|(% style="width:368px" %)Voltage in the reference line of the auxiliary current sensor, V|(% style="width:96px" %)REAL32 447 -|(% style="width:92px" %)**0x219F**|(% style="width:94px" %)2|(% style="width:368px" %)Charge current limit, A|(% style="width:96px" %)REAL32 448 -|(% style="width:92px" %)**0x21A1**|(% style="width:94px" %)2|(% style="width:368px" %)Discharge current limit, A|(% style="width:96px" %)REAL32 443 +|(% style="width:92px" %)**0x218E-0x218F**|(% style="width:94px" %)2|(% style="width:368px" %)Voltage from the current sensor, V|(% style="width:96px" %)REAL32 444 +|(% style="width:92px" %)**0x2190-0x2191**|(% style="width:94px" %)2|(% style="width:368px" %)Voltage in the reference line of the current sensor, V|(% style="width:96px" %)REAL32 445 +|(% style="width:92px" %)**0x2192-0x2193**|(% style="width:94px" %)2|(% style="width:368px" %)Voltage from the auxiliary current sensor, V|(% style="width:96px" %)REAL32 446 +|(% style="width:92px" %)**0x2194-0x2195**|(% style="width:94px" %)2|(% style="width:368px" %)Voltage in the reference line of the auxiliary current sensor, V|(% style="width:96px" %)REAL32 447 +|(% style="width:92px" %)**0x219F-0x21A0**|(% style="width:94px" %)2|(% style="width:368px" %)Charge current limit, A|(% style="width:96px" %)REAL32 448 +|(% style="width:92px" %)**0x21A1-0x21A2**|(% style="width:94px" %)2|(% style="width:368px" %)Discharge current limit, A|(% style="width:96px" %)REAL32 449 449 |(% style="width:92px" %)**0x21B8**|(% style="width:94px" %)1|(% style="width:368px" %)Flag indicating that the cells are balancing|(% style="width:96px" %)U16 450 -|(% style="width:92px" %)**0x21C6**|(% style="width:94px" %)2|(% style="width:368px" %)Calibrated voltage in the reference line of the auxiliary current sensor, V|(% style="width:96px" %)REAL32 451 -|(% style="width:92px" %)**0x21CA**|(% style="width:94px" %)2|(% style="width:368px" %)Average cell voltage, V|(% style="width:96px" %)REAL32 450 +|(% style="width:92px" %)**0x21C6-0x21C7**|(% style="width:94px" %)2|(% style="width:368px" %)Calibrated voltage in the reference line of the auxiliary current sensor, V|(% style="width:96px" %)REAL32 451 +|(% style="width:92px" %)**0x21CA-0x21CB**|(% style="width:94px" %)2|(% style="width:368px" %)Average cell voltage, V|(% style="width:96px" %)REAL32 452 452 |(% style="width:92px" %)**0x2200-0x2203**|(% style="width:94px" %)4|(% style="width:368px" %)((( 453 453 Record #1 from the errors journal. First 32-bit word contains a timestamp, second 32-bit word contains errors 1 flags (see 0x2007-0x2008). 454 454 ... ... @@ -470,12 +470,12 @@ 470 470 |(% style="width:92px" %)**0x2208-0x227B**|(% style="width:94px" %) |(% style="width:368px" %)Records #3-31 from the errors journal|(% style="width:96px" %) 471 471 |(% style="width:92px" %)**0x227C-0x227F**|(% style="width:94px" %)4|(% style="width:368px" %)Record #32 from the errors journal|(% style="width:96px" %)U32[2] 472 472 |(% style="width:92px" %)**0x2300**|(% style="width:94px" %)1|(% style="width:368px" %)Number of the last record from the errors journal (1..32)|(% style="width:96px" %)U16 473 -|(% style="width:92px" %)**0x2380**|(% style="width:94px" %)4|(% style="width:368px" %)Record data #1 from the errors journal. First 32-bit word contains errors 2 flags (see 0x200E-0x200F).|(% style="width:96px" %)U32[2] 473 +|(% style="width:92px" %)**0x2380-0x2383**|(% style="width:94px" %)4|(% style="width:368px" %)Record data #1 from the errors journal. First 32-bit word contains errors 2 flags (see 0x200E-0x200F).|(% style="width:96px" %)U32[2] 474 474 |(% style="width:92px" %)**0x2384-0x2387**|(% style="width:94px" %)4|(% style="width:368px" %)Record data #2 from the errors journal|(% style="width:96px" %)U32[2] 475 475 |(% style="width:92px" %)**0x2388-0x23FB**|(% style="width:94px" %) |(% style="width:368px" %)Records data #3-31 from the errors journal|(% style="width:96px" %) 476 476 |(% style="width:92px" %)**0x23FC-0x23FF**|(% style="width:94px" %)4|(% style="width:368px" %)Record data #32 from the errors journal|(% style="width:96px" %)U32[2] 477 -|(% style="width:92px" %)**0x2400**|(% style="width:94px" %)2|(% style="width:368px" %)Current measured by the auxiliary current sensor, A|(% style="width:96px" %)REAL32 478 -|(% style="width:92px" %)**0x2402**|(% style="width:94px" %)2|(% style="width:368px" %)((( 477 +|(% style="width:92px" %)**0x2400-0x2401**|(% style="width:94px" %)2|(% style="width:368px" %)Current measured by the auxiliary current sensor, A|(% style="width:96px" %)REAL32 478 +|(% style="width:92px" %)**0x2402-0x2403**|(% style="width:94px" %)2|(% style="width:368px" %)((( 479 479 Final battery current, A 480 480 481 481 Note — Typically it is the sum of the values measured by the main and auxiliary current sensors