1 The BMS Main 2.x board continuously monitors the state of the cells, BMS Logic boards, the external environment and, when detecting abnormalities, protects the battery and system components from damage.
2
3 == 3.6.1 Overcurrent protection ==
4
5 To change the current protection of the battery, select the menu "Protections → Overcurrent protection":
6
7 [[Overcurrent protection settings>>image:1732211959984-118.png||data-xwiki-image-style-alignment="center" height="266" width="386"]]
8
9 In this section:
10
11 * Enable – a flag to enable the protection;
12 * Maximum charging current, А;
13 * Tolerant charging current, А;
14 * Maximum discharging current, А;
15 * Tolerant discharging current, А;
16 * Delay before setting the error, second;
17 * Delay before clearing the error, second;
18 * Lock the error until the device is reset – a flag to block the error until the board is restarted.
19
20 As a result of operation of the current protection, the "Overcurrent" error is generated.
21
22 Error generation conditions:
23
24 * the current is positive (charging), and its modulo value is greater than the “Maximum charging current” value for the “Delay before setting the error” time;
25 * the current is negative (discharging), and its modulo value is greater than the “Maximum discharging current” value for the “Delay before setting the error” time.
26
27 Conditions for removing the error:
28
29 * the current is positive (charging) or zero, and its modulo value is less than the “Tolerant charging current” value for the “Delay before clearing the error” time;
30 * the current is negative (discharging), and its modulo value is less than the “Tolerant discharging current” value for the “Delay before clearing the error” time.
31
32 (% class="box infomessage" %)
33 (((
34 If there is the "Overcurrent" error, the charging and discharging relay open.
35 )))
36
37 == 3.6.2 Undervoltage protection ==
38
39 The board implements battery protection from too low or too high voltage on the cells.
40
41 To change the battery protection parameters from low voltage on the cells, select the menu "Protections → Undervoltage protection":
42
43 [[Undervoltage protection settings>>image:1732212212350-294.png||data-xwiki-image-style-alignment="center" height="207" width="359"]]
44
45 In this section:
46
47 * Enable – a flag to enable the protection;
48 * Minimum cell voltage, V;
49 * Tolerant cell voltage, V;
50 * Delay before setting the error, second;
51 * Delay before clearing the error, second;
52 * Lock the error until the device is reset.
53
54 As a result of the operation of battery protection from low voltage, the "Undervoltage" error is generated.
55
56 Error generation conditions:
57
58 * the minimum voltage among all cells of the battery is less than the “Minimum cell voltage” value for the “Delay before setting the error” time.
59
60 Conditions for removing the error:
61
62 * the minimum voltage among all cells of the battery is greater than the “Tolerant cell voltage” value for the “Delay before clearing the error” time.
63
64 (% class="box infomessage" %)
65 (((
66 If there is the "Undervoltage" error, the discharging relay opens.
67 )))
68
69 3.6.3 Overvoltage protection
70
71 To change the battery protection parameters from high voltage on the cells, select the menu "Protections → Overvoltage protection":
72
73 [[image:1732212357972-295.png]]
74
75 In this section:
76
77 * Enable – a flag to enable the protection;
78 * Maximum cell voltage, V;
79 * Tolerant cell voltage, V;
80 * Delay before setting the error, second;
81 * Delay before clearing the error, second;
82 * Switch off the discharging relay on error – a flag to open the discharging relay when the "Overvoltage" error is generated;
83 * Lock the error until the device is reset.
84
85 As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated.
86
87 Error generation conditions:
88
89 * the maximum voltage among all cells of the battery is greater than the “Maximum cell voltage” value for the “Delay before setting the error” time.
90
91 Conditions for removing the error:
92
93 * the maximum voltage among all cells of the battery is less than the “Tolerant cell voltage” value for the “Delay before clearing the error” time.
94
95 (% class="box infomessage" %)
96 (((
97 If there is the "Overvoltage" error, the charging relay and discharging relay opens (if the “Switch off the discharging relay on error” flag is set).
98 )))
99
100 == 3.6.4 Low temperature protection ==
101
102 The board implements battery protection from too low temperature.
103
104 To change the battery protection parameters from low temperature, select the menu "Protections → Low temperature protection":
105
106
107 In this section:
108
109 * Enable – a flag to enable the protection;
110 * Minimum charging temperature, °C;
111 * Tolerant charging temperature, °C;
112 * Minimum discharging temperature, °C;
113 * Tolerant discharging temperature, °C;
114 * Delay before setting the error, second;
115 * Delay before clearing the error, second;
116 * Lock the error until the device is reset.
117
118 As a result of the operation of the battery protection from low temperature, the "Low CH temperature" or “Low DCH temperature” error is generated.
119
120 Error generation conditions:
121
122 * the minimum temperature among all cells of the battery is less than the “Minimum charging (discharging) temperature” value for the “Delay before setting the error” time.
123
124 Conditions for removing the error:
125
126 * the minimum temperature among all cells of the battery is greater than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time.
127
128 (% class="box infomessage" %)
129 (((
130 If there is the "Low CH temperature" error, the charging relay opens.
131 If there is the "Low DCH temperature" error, the discharging relay opens.
132 )))
133
134 == 3.6.5 High temperature protection ==
135
136 The board implements battery protection from too high temperature.
137
138 To change the battery protection parameters from high temperature, select the menu "Protections → High temperature protection":
139
140
141 In this section:
142
143 * Enable – a flag to enable the protection;
144 * Maximum charging temperature, °C;
145 * Tolerant charging temperature, °C;
146 * Maximum discharging temperature, °C;
147 * Tolerant discharging temperature, °C;
148 * Delay before setting the error, second;
149 * Delay before clearing the error, second;
150 * Lock the error until the device is reset.
151
152 As a result of the operation of the battery protection from high temperature, the "High CH temperature" or “High DCH temperature” error is generated.
153
154 Error generation conditions:
155
156 * the maximum temperature among all cells of the battery is greater than the “Maximum charging (discharging) temperature” value for the “Delay before setting the error” time.
157
158 Conditions for removing the error:
159
160 * the maximum temperature among all cells of the battery is less than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time.
161
162 (% class="box infomessage" %)
163 (((
164 If there is the "High CH temperature" error, the charging relay opens.
165 If there is the "High DCH temperature" error, the discharging relay opens.
166 )))
167
168 == 3.6.6 Battery cover protection ==
169
170 To change the protection parameters from opening the battery cover, select the menu "Protections → Battery cover protection":
171
172 In this section:
173
174 * Enable – a flag to enable the protection;
175 * Delay before setting the error, second;
176 * Delay before clearing the error, second;
177 * Lock the error until the device is reset.
178
179 As a result of the operation of the protection against opening the battery cover, the “Battery cover error” is generated.
180
181 Error generation conditions:
182
183 * there is a signal from the battery cover during the “Delay before setting the error” time.
184
185 Conditions for removing the error:
186
187 * no signal from the battery cover during the “Delay before clearing the error” time.
188
189 (% class="box warningmessage" %)
190 (((
191 **If there is the "Battery cover error", the “Critical error” is generated and all relays open.**
192 )))
193
194 == 3.6.7 High humidity protection ==
195
196 The board can protect the battery from high humidity and water.
197
198 To change the protection parameters of the battery from high humidity, select the menu "Protections → High humidity protection":
199
200
201 In this section:
202
203 * Enable – a flag to enable the protection;
204 * Maximum humidty, RH%;
205 * Tolerant humidty, RH%;
206 * Delay before setting the error, second;
207 * Delay before clearing the error, second;
208 * Lock the error until the device is reset.
209
210 As a result of the operation of the battery protection from high humidity, the "High humidity" error is generated.
211
212 Error generation conditions:
213
214 * the measured humidity is greater than “Maximum humidity” during the “Delay before setting the error” time.
215
216 Conditions for removing the error:
217
218 * the measured humidity is less than the “Tolerant humidity” during the “Delay before clearing the error” time.
219
220 (% class="box infomessage" %)
221 (((
222 If there is the "High humidity" error, no action is taken. The error is indicative.
223 )))
224
225 == 3.6.8  Water protection ==
226
227 To change the protection parameters of the battery from water, select the menu "Protections → Water protection":
228
229
230 In this section:
231
232 * Enable – a flag to enable the protection;
233 * Maximum (water) humidty, RH%;
234 * Tolerant humidity, RH%;
235 * Delay before setting the error, second;
236 * Delay before clearing the error, second;
237 * Lock the error until the device is reset.
238
239 As a result of the operation of the battery protection from water, the "Water" error is generated.
240
241 Error generation conditions:
242
243 * the measured humidity is greater than the “Maximum (water) humidity” value during the “Delay before setting the error” time.
244
245 Conditions for removing the error:
246
247 * the measured humidity is less than the “Tolerant humidity” value during the “Delay before clearing the error” time.
248
249 (% class="box warningmessage" %)
250 (((
251 **If there is the “Water” error, the “Critical error” is generated and all relays open.**
252 )))
253
254 == 3.6.9 Current sensor error ==
255
256 The board is implemented to check the current sensor connection circuits. The circuits are checked for breakage and short-circuit to the +5 V supply line.
257
258 To change the test parameters of the current sensor connection circuits, select the menu "Protections → Current sensor error":
259
260
261 In this section:
262
263 * Enable – a flag to enable the protection;
264 * Maximum voltage, V;
265 * Minimum voltage, V;
266 * Hysteresis voltage – a hysteresis value to clear the error, V;
267 * Delay before setting the error, second;
268 * Delay before clearing the error, second;
269 * Lock the error until the device is reset.
270
271 If there is an open or short circuit connection of a current sensor, the "Current sensor error" is generated.
272
273 Error generation conditions:
274
275 * the voltage in the signal line or zero level line of the current sensor is greater than the “Maximum voltage” value during the “Delay before setting the error” time;
276 * the voltage in the signal line or zero level line of the current sensor is less than the “Minimum voltage” value during the “Delay before setting the error” time.
277
278 Conditions for removing the error:
279
280 * the voltage in the signal line or zero level line of the current sensor is in range from (Minimum voltage + Hysteresis voltage) to (Maximum voltage - Hysteresis voltage) during the “Delay before clearing the error” time.
281
282 (% class="box warningmessage" %)
283 (((
284 **If there is the “Current sensor error”, the “Critical error” is generated and all relays open.**
285 )))
286
287 == 3.6.10 Short circuit protection ==
288
289 The BMS implements a protection of power circuits (contactors, power cables) against overheating caused by the flow of high current for a long time.
290
291 To change the protection parameters from short circuit, select the menu "Protections → Short circuit protection":
292
293
294 In this section:
295
296 * Level 1, 2, 3 – three protection levels. The following parameters are configured at each level:
297 ** Enable – a flag to enable the protection;
298 ** Maximum current, A;
299 ** Delay before setting the error, second;
300 * Delay before clearing the error, second;
301 * Switch off the charging relay on error – a flag to open the charging relay when the "Short circuit" error occurs;
302 * Switch off the discharging relay on error – a flag to open the discharging relay when the "Short circuit" error occurs;
303 * Lock the error until the device is reset.
304
305 If there is a short circuit, the "Short circuit" error is generated.
306
307 Error generation conditions:
308
309 * at any of the three protection levels, the current modulo is greater than the “Maximum current” value during the “Delay before setting the error” time.
310
311 Conditions for removing the error:
312
313 * the current modulo is lower than the “Maximum current” values for all three protection levels during the “Delay before setting the error” time.
314
315 (% class="box infomessage" %)
316 (((
317 If there is the "Short circuit" error, the charging relay opens (the “Switch off the charging relay on error” flag is set) and the discharging relay opens (the “Switch off the discharging relay on error flag” is set).
318 )))
319
320 == 3.6.11 Contactor high temperature protection ==
321
322 The BMS protects power contactors from overheating. To measure the temperature of the contactor, a thermistor is used, connected to the P13 connector of the board. Configuring of the analog input for temperature measurement is described in section Input signals.
323
324 To change the overheating protection parameters of power contactors, select the menu "Protections → Contactor high temperature protection":
325
326
327 In this section:
328
329 * Enable – a flag to enable the protection;
330 * Maximum temperature, °C;
331 * Tolerant temperature, °C;
332 * Delay before setting the error, second;
333 * Delay before clearing the error, second;
334 * Switch off the charging relay on error – a flag to open the charging relay when the "Contactor high temperature" error occurs;
335 * Switch off the discharging relay on error – a flag to open the discharging relay when the "Contactor high temperature" error occurs;
336 * Lock the error until the device is reset.
337
338 If there is a contactor overheat, the "Contactor high temperature" error is generated.
339
340 Error generation conditions:
341
342 * the contactor temperature is greater than the “Maximum temperature” value during the “Delay before setting the error” time.
343
344 Conditions for removing the error:
345
346 * the contactor temperature is lower than the “Tolerant temperature” value during the “Delay before clearing the error” time.
347
348 (% class="box infomessage" %)
349 (((
350 If there is the "Contactor high temperature" error, the charging relay opens (the “Switch off the charging relay on error” flag is set) and the discharging relay opens (the “Switch off the discharging relay on error flag” is set).
351 )))
352
353 == 3.6.12 Unallowable charging protection ==
354
355 The BMS can detect that the battery is charging through the discharging circuit and protectively open the discharging relay to prevent unallowable battery operation.
356
357 To change the parameters of the unallowable charging protection, select the menu "Protections → Unallowable charging protection":
358
359
360 In this section:
361
362 * Enable – a flag to enable the protection;
363 * Delay before setting the error, second;
364 * Delay before clearing the error, second;
365 * Lock the error until the device is reset.
366
367 If there is charging the battery through the discharging circuit detected, the "Unallowable charging" error is generated.
368
369 Error generation conditions:
370
371 * the charging relay is open and the battery current is not zero during the “Delay before setting the error” time.
372
373 Conditions for removing the error:
374
375 * the battery current is zero during the “Delay before clearing the error” time.
376
377 (% class="box infomessage" %)
378 (((
379 If there is the "Unallowable charging" error, the discharging relay opens.
380 )))
381
382 == 3.6.13 Stuck contactor protection ==
383
384 The BMS Main 2.x protects contactors against sticking.
385
386 To change the protection parameters against sticking, select the menu "Protections → Stuck contactor protection":
387
388
389 In this section:
390
391 * Enable – a flag to enable the protection;
392 * Delay before setting the error, second;
393 * Delay before clearing the error, second;
394 * Lock the error until the device is reset;
395
396 If there is a stuck contactor, the “Stuck contactor” error is generated.
397
398 Error generation conditions:
399
400 * charging and discharging contactors are open, but the “Charging current present” or “Discharging current present” signal is set.
401
402 == 3.6.14 Contactor feedback check ==
403
404 The BMS Main 2.x can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, one of the discrete input must be set as corresponding contactor feedback signal (see section Input and output signals).
405
406 To change the contactor feedback check parameters, select the menu "Protections → Contactor feedback check":
407
408
409 In this section:
410
411 * Enable – a flag to enable the protection;
412 * Delay before setting the error, second;
413 * Delay before clearing the error, second;
414 * Lock the error until the device is reset;
415
416 If there is a discrepancy at any contactor, the corresponding contactor feedback error is generated. Error generation conditions:
417
418 * discrete output of charging, precharge, discharging, charging/discharging or main contactor not matches its feedback value.
419
420 == 3.6.15 Charging contactor cycles protection ==
421
422
423 == 3.6.16 Discharging contactor cycles protection ==
424
425 == 3.6.17 Temperature sensor error ==
426
427 == 3.6.18 Logic high temperature protection ==
428
429 == 3.6.19 Logic offline protection ==
430
431 == 3.6.20 Cell count protection ==
432
433 == 3.6.21 Logic count protection ==
434
435 == 3.6.22 WDT protection ==
436
437 == 3.6.23 Insulation monitoring ==
438
439 == 3.6.24 Critical error parameters ==
440
441 == 3.6.25 General error parameters ==
442
443 == 3.6.26 Low SOC signal ==
444
445 == 3.6.27 High charging current signal ==
446
447 == 3.6.28 Heater control ==
448
449 == 3.6.29 Heater (AUX) control ==
450
451 == 3.6.30 Cooler control ==
452
453 == 3.6.31 Fault simulation ==