Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -616,252 +616,20 @@ 616 616 To change the parameters of the watchdog protection, select the menu "Protections → WDT protection": 617 617 618 618 619 -In this section: 620 - 621 -* Enable – a flag to enable the protection; 622 -* Delay before clearing the error, second; 623 -* Lock the error until the device is reset. 624 - 625 -Conditions for removing the error: 626 - 627 -* the “Delay before clearing the error” time has passed from the board startup. 628 - 629 -(% class="box warningmessage" %) 630 -((( 631 -**If there is the "WDT reset" error, the “Critical error” is generated and all relays open.** 632 -))) 633 - 634 634 == 3.6.23 Insulation monitoring == 635 635 636 -BMS Main 2.x can detect a signal from an external insulation monitoring device (such as Bender IR155) to monitor the insulation quality. 637 - 638 -To change the insulation monitoring parameters, select the menu "Protections → Insulation monitoring": 639 - 640 - 641 -In this section: 642 - 643 -* Enable – a flag to enable the protection; 644 -* Delay before setting the error, second; 645 -* Delay before clearing the error, second; 646 -* Lock the error until the device is reset. 647 - 648 -Error is set if corresponding discrete input is set up and it received logical zero. 649 - 650 650 == 3.6.24 Critical error parameters == 651 651 652 -To change the critical error parameters, select the menu "Protections → Critical error parameters": 653 - 654 - 655 -In this section: 656 - 657 -* Enable – a flag to enable the protection; 658 -* Delay before setting the error, second; 659 -* Delay before clearing the error, second; 660 -* Lock the error until the device is reset. 661 - 662 -The critical error flag is generated if at least one of the following errors is generated during the “Delay before setting the error” time: 663 - 664 -* “Battery cover error”; 665 -* “Water”; 666 -* “Logic offline”; 667 -* “Cell count error”; 668 -* “Logic count error”; 669 -* “ADC error”; 670 -* “No temp. sensors”; 671 -* “Temp. sensor is shorted”; 672 -* “Current sensor error”; 673 -* “Shunt offline”; 674 -* “Shunt error”; 675 -* “Settings error”; 676 -* “WDT reset”. 677 - 678 -The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 679 - 680 -(% class="box warningmessage" %) 681 -((( 682 -**If there is the “Critical error”, all relays open.** 683 -))) 684 - 685 685 == 3.6.25 General error parameters == 686 686 687 687 == 3.6.26 Low SOC signal == 688 688 689 -To change the parameters of the generation a signal about low battery level, select the menu "Protections → Low SOC signal": 690 - 691 - 692 -In this section: 693 - 694 -* Enable – a flag to enable signal generation; 695 -* Minimum SOC, %; 696 -* Tolerant SOC, %; 697 -* Delay before setting the signal, second; 698 -* Delay before clearing the signal, second; 699 -* Lock the signal until the device is reset. 700 - 701 -Signal generation conditions: 702 - 703 -* the battery SOC is less than the “Minimum SOC” value during the “Delay before setting the signal” time. 704 - 705 -Conditions for clearing the signal: 706 - 707 -* the battery SOC is greater than the “Tolerant SOC” during the “Delay before clearing the signal” time. 708 - 709 -The "Low SOC signal" is //indicative //and can be linked to any discrete output of the board. 710 - 711 711 == 3.6.27 High charging current signal == 712 712 713 -To change the parameters of the generation high-current signal, select the menu "Protections → High charging current signal": 714 - 715 - 716 -In this section: 717 - 718 -* Enable – a flag to enable signal generation; 719 -* Maximum charging current, А; 720 -* Tolerant charging current, А; 721 -* Delay before setting the signal, second; 722 -* Delay before clearing the signal, second; 723 -* Lock the signal until the device is reset. 724 - 725 -Signal generation conditions: 726 - 727 -* the measured current is greater than the “Maximum charging current” value during the “Delay before setting the signal” time. 728 - 729 -Conditions for clearing the signal: 730 - 731 -* the measured current is less than the “Tolerant charging current” value during the “Delay before clearing the signal” time. 732 - 733 -The "High charging current" signal is //indicative //and can be linked to any discrete output of the board. 734 - 735 735 == 3.6.28 Heater control == 736 736 737 -To change the parameters of the heater control algorithm, select the menu "Protections → Heater control": 738 - 739 - 740 -In this section: 741 - 742 -* Enable – a flag to enable heater control; 743 -* Minimum cell temperature, °C; 744 -* Tolerant cell temperature, °C; 745 -* Delay before setting the signal, second; 746 -* Delay before clearing the signal, second; 747 -* Lock the signal until the device is reset; 748 -* Switch off the heater relay on errors (Undervoltage, Overcurrent, High temperature, Short circuit or Critical error). 749 - 750 -As a result of operating the heating algorithm, the “Heater” signal is generated. 751 - 752 -Conditions of signal generation: 753 - 754 -* The minimum temperature among all cells of the battery is less than the “Minimum cell temperature” value during the “Delay before setting the signal” time. 755 - 756 -Conditions for clearing the signal: 757 - 758 -* the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before clearing the signal” time. 759 - 760 -(% class="box infomessage" %) 761 -((( 762 -If there is the "Heater" signal, the heater relay closes and/or a signal is output to the corresponded digital output. 763 -))) 764 - 765 765 == 3.6.29 Heater (AUX) control == 766 766 767 -To change the parameters of the auxiliary heater control algorithm, select the menu "Protections → Heater (AUX) control": 768 - 769 - 770 -In this section: 771 - 772 -* Enable – a flag to enable heater control; 773 -* Minimum cell temperature, °C; 774 -* Tolerant cell temperature, °C; 775 -* Delay before setting the signal, second; 776 -* Delay before clearing the signal, second; 777 -* Lock the signal until the device is reset; 778 -* Switch off the heater relay on errors (Undervoltage, Overcurrent, High temperature, Short circuit or Critical error). 779 - 780 -As a result of operating the heating algorithm, the “Heater (AUX)” signal is generated. 781 - 782 -Conditions of signal generation: 783 - 784 -* The minimum temperature among all cells of the battery is less than the “Minimum cell temperature” value during the “Delay before setting the signal” time. 785 - 786 -Conditions for clearing the signal: 787 - 788 -* the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before clearing the signal” time. 789 - 790 -(% class="box infomessage" %) 791 -((( 792 -If there is the "Heater (AUX)" signal, the auxiliary heater relay closes and/or a signal is output to the corresponded digital output. 793 -))) 794 - 795 795 == 3.6.30 Cooler control == 796 796 797 -To change the parameters of the cooler control algorithm, select the menu "Protections → Cooler control": 798 - 799 - 800 -In this section: 801 - 802 -* Enable – a flag to enable cooler control; 803 -* Maximum cell temperature, °C; 804 -* Tolerant cell temperature, °C; 805 -* Delay before setting the signal, second; 806 -* Delay before clearing the signal, second; 807 -* Lock the signal until the device is reset; 808 -* Switch off the cooler relay on errors (Undervoltage, Overcurrent, Low temperature, Short circuit or Critical error). 809 - 810 -As a result of operating the cooling algorithm, the "Cooler" signal is generated. 811 - 812 -Conditions of signal generation: 813 - 814 -* the maximum temperature among all cells of the battery is greater than the “Maximum cell temperature” value during the “Delay before setting the signal” time. 815 - 816 -Conditions for clearing the signal: 817 - 818 -* the maximum temperature among all cells of the battery is less than the “Tolerant cell temperature” value during the “Delay before clearing the signal” time. 819 - 820 -(% class="box infomessage" %) 821 -((( 822 -If there is the "Cooler" signal, the cooler relay closes and/or a signal is output to the corresponded digital output. 823 -))) 824 - 825 825 == 3.6.31 Fault simulation == 826 - 827 -The board provides the ability to manually generate error flags bypassing the protection algorithms. This functionality is intended for commissioning. 828 - 829 -To simulate battery and BMS errors, select the menu "Protections → Fault simulation": 830 - 831 - 832 -In this section: 833 - 834 -* Overcurrent; 835 -* Undervoltage; 836 -* Overvoltage; 837 -* Low CH temperature; 838 -* Low DCH temperature; 839 -* High CH temperature; 840 -* High DCH temperature; 841 -* Battery cover error; 842 -* High humidity; 843 -* Water; 844 -* Current sensor error; 845 -* Short circuit; 846 -* Contactor high temperature; 847 -* Unallowable charging; 848 -* Stuck contactor; 849 -* CH contactor feedback error; 850 -* DCH contactor feedback error; 851 -* PCH contactor feedback error; 852 -* CH/DCH contactor feedback error; 853 -* Main contactor feedback error; 854 -* CH contactor cycles error; 855 -* DCH contactor cycles error; 856 -* Logic high temperature; 857 -* Logic offline; 858 -* Cell count error; 859 -* Logic count error; 860 -* Insulation error; 861 -* Critical error; 862 -* Low SOC; 863 -* High charging current; 864 -* Heater; 865 -* Cooler. 866 - 867 -To simulate errors, set the necessary flags and click on the "Save" button.
- 1732213953083-955.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -22.0 KB - Content
- 1732213990755-759.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -22.7 KB - Content