... ... @@ -56,7 +56,7 @@
56 56  * Enable – a flag to enable the protection;
57 57  * Minimum cell voltage, V;
58 58  * Tolerant cell voltage, V;
59 -* Check the open circuit voltage instead of the actual voltage – a flag to enable U,,ocv,, correction depending on cell current and resistance;
59 +* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage;
60 60  * Delay before setting the error, second;
61 61  * Delay before clearing the error, second;
62 62  * Lock the error until the device is reset.
... ... @@ -87,7 +87,7 @@
87 87  * Enable – a flag to enable the protection;
88 88  * Maximum cell voltage, V;
89 89  * Tolerant cell voltage, V;
90 -* Check the open circuit voltage instead of the actual voltage – a flag to enable U,,ocv,, correction depending on cell current and resistance;
90 +* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage;
91 91  * Delay before setting the error, second;
92 92  * Delay before clearing the error, second;
93 93  * Switch off the discharging relay on error – a flag to open the discharging relay when the "Overvoltage" error is generated;