... ... @@ -21,7 +21,9 @@
21 21  * Tolerant discharging current, А;
22 22  * Delay before setting the error, second;
23 23  * Delay before clearing the error, second;
24 -* Use other delays if the battery is discharging – a flag to enable alternative timings for
24 +* Use other delays if the battery is discharging – a flag to enable alternative timings for battery discharging;
25 +* Discharging: Delay before setting the error, second;
26 +* Discharging: Delay before clearing the error, second;
25 25  * Lock the error until the device is reset – a flag to block the error until the board is restarted.
26 26  
27 27  As a result of operation of the current protection, the "Overcurrent" error is generated.
... ... @@ -54,7 +54,7 @@
54 54  * Enable – a flag to enable the protection;
55 55  * Minimum cell voltage, V;
56 56  * Tolerant cell voltage, V;
57 -* Check the open circuit voltage instead of the actual voltage – a flag to enable U,,ocv,, correction depending on cell current and resistance;
59 +* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage;
58 58  * Delay before setting the error, second;
59 59  * Delay before clearing the error, second;
60 60  * Lock the error until the device is reset.
... ... @@ -85,7 +85,7 @@
85 85  * Enable – a flag to enable the protection;
86 86  * Maximum cell voltage, V;
87 87  * Tolerant cell voltage, V;
88 -* Check the open circuit voltage instead of the actual voltage – a flag to enable U,,ocv,, correction depending on cell current and resistance;
90 +* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage;
89 89  * Delay before setting the error, second;
90 90  * Delay before clearing the error, second;
91 91  * Switch off the discharging relay on error – a flag to open the discharging relay when the "Overvoltage" error is generated;