Changes for page 3.6 Battery protection

Last modified by Admin on 2025/04/09 12:25

From version 46.1
edited by Admin
on 2025/04/02 10:06
Change comment: Uploaded new attachment "1743588404359-971.png", version {1}
To version 41.1
edited by Admin
on 2025/01/10 09:49
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -46,7 +46,7 @@
46 46  
47 47  To change the battery protection parameters from low voltage on the cells, select the menu "Protections → Undervoltage protection":
48 48  
49 -[[image:1739960999969-617.png||alt="1739961158202-478.png" data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="228" width="351"]]
49 +[[image:1732212212350-294.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="207" width="359"]]
50 50  
51 51   In this section:
52 52  
... ... @@ -53,7 +53,6 @@
53 53  * Enable – a flag to enable the protection;
54 54  * Minimum cell voltage, V;
55 55  * Tolerant cell voltage, V;
56 -* Check the open circuit voltage instead of the actual voltage – a flag to enable U,,ocv,, correction depending on cell current and resistance;
57 57  * Delay before setting the error, second;
58 58  * Delay before clearing the error, second;
59 59  * Lock the error until the device is reset.
... ... @@ -77,7 +77,7 @@
77 77  
78 78  To change the battery protection parameters from high voltage on the cells, select the menu "Protections → Overvoltage protection":
79 79  
80 -[[image:1739961158202-478.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="237" width="353"]]
79 +[[image:1732212357972-295.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="218" width="338"]]
81 81  
82 82  In this section:
83 83  
... ... @@ -84,7 +84,6 @@
84 84  * Enable – a flag to enable the protection;
85 85  * Maximum cell voltage, V;
86 86  * Tolerant cell voltage, V;
87 -* Check the open circuit voltage instead of the actual voltage – a flag to enable U,,ocv,, correction depending on cell current and resistance;
88 88  * Delay before setting the error, second;
89 89  * Delay before clearing the error, second;
90 90  * Switch off the discharging relay on error – a flag to open the discharging relay when the "Overvoltage" error is generated;
... ... @@ -628,7 +628,7 @@
628 628  
629 629  * Enable – a flag to enable the protection;
630 630  * Logic count – a number of BMS Logic boards connected to the BMS Main 2.x;
631 -* Fast scanning – a flag to scan BMS Logic boards fast (boards with addresses from 1 to “Logic count” are scanned; this mode reduces BMS system startup time);
629 +* Fast scan – a flag to scan BMS Logic boards fast (boards with addresses from 1 to “Logic count” are scanned; this mode reduces BMS system startup time);
632 632  * Lock the error until the device is reset.
633 633  
634 634  As a result of the operation of the protection from the mismatch of the number of BMS Logic boards, the "Logic count error" is generated.
... ... @@ -680,10 +680,6 @@
680 680  In this section:
681 681  
682 682  * Enable – a flag to enable the protection;
683 -* Algorithm:
684 -** Always;
685 -** On charging;
686 -** Except charging;
687 687  * Delay before setting the error, second;
688 688  * Delay before clearing the error, second;
689 689  * Lock the error until the device is reset.
1739960999969-617.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -19.8 KB
Content
1739961158202-478.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -22.3 KB
Content
1743588404359-971.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -29.7 KB
Content