Summary

Details

Page properties
Content
... ... @@ -10,7 +10,7 @@
10 10  
11 11  To change the current protection of the battery, select the menu "Protections → Overcurrent protection":
12 12  
13 -[[image:1732211959984-118.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="266" width="386"]]
13 +[[image:1743588404359-971.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="325" width="450"]]
14 14  
15 15   In this section:
16 16  
... ... @@ -21,6 +21,7 @@
21 21  * Tolerant discharging current, А;
22 22  * Delay before setting the error, second;
23 23  * Delay before clearing the error, second;
24 +* Use other delays if the battery is discharging – a flag to enable alternative timings for
24 24  * Lock the error until the device is reset – a flag to block the error until the board is restarted.
25 25  
26 26  As a result of operation of the current protection, the "Overcurrent" error is generated.
... ... @@ -53,7 +53,7 @@
53 53  * Enable – a flag to enable the protection;
54 54  * Minimum cell voltage, V;
55 55  * Tolerant cell voltage, V;
56 -* Check the open circuit voltage instead of the actual voltage – a flag to enable Uocv correction depending on current ;
57 +* Check the open circuit voltage instead of the actual voltage – a flag to enable U,,ocv,, correction depending on cell current and resistance;
57 57  * Delay before setting the error, second;
58 58  * Delay before clearing the error, second;
59 59  * Lock the error until the device is reset.
... ... @@ -84,6 +84,7 @@
84 84  * Enable – a flag to enable the protection;
85 85  * Maximum cell voltage, V;
86 86  * Tolerant cell voltage, V;
88 +* Check the open circuit voltage instead of the actual voltage – a flag to enable U,,ocv,, correction depending on cell current and resistance;
87 87  * Delay before setting the error, second;
88 88  * Delay before clearing the error, second;
89 89  * Switch off the discharging relay on error – a flag to open the discharging relay when the "Overvoltage" error is generated;