Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - Battery managementystems.BMS Main 2\.1.3\. Configuration.WebHome1 +drafts.BMS Main 2\.1.3\. Configuration.WebHome - Content
-
... ... @@ -46,7 +46,7 @@ 46 46 47 47 To change the battery protection parameters from low voltage on the cells, select the menu "Protections → Undervoltage protection": 48 48 49 -[[image:173 9960999969-617.png||alt="1739961158202-478.png"data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="228" width="351"]]49 +[[image:1732212212350-294.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="207" width="359"]] 50 50 51 51 In this section: 52 52 ... ... @@ -53,7 +53,6 @@ 53 53 * Enable – a flag to enable the protection; 54 54 * Minimum cell voltage, V; 55 55 * Tolerant cell voltage, V; 56 -* Check the open circuit voltage instead of the actual voltage – a flag to enable Uocv correction depending on current ; 57 57 * Delay before setting the error, second; 58 58 * Delay before clearing the error, second; 59 59 * Lock the error until the device is reset. ... ... @@ -77,7 +77,7 @@ 77 77 78 78 To change the battery protection parameters from high voltage on the cells, select the menu "Protections → Overvoltage protection": 79 79 80 -[[image:173 9961158202-478.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="237" width="353"]]79 +[[image:1732212357972-295.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="218" width="338"]] 81 81 82 82 In this section: 83 83 ... ... @@ -424,7 +424,7 @@ 424 424 425 425 === Contactor feedback check === 426 426 427 -The BMS Main 2.x can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, one of the discrete input must be set as corresponding contactor feedback signal (see [[Input and output signals>>doc: Battery managementystems.BMS Main 2\.1.3\. Configuration.3\.3 Input and output signals.WebHome]]).426 +The BMS Main 2.x can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, one of the discrete input must be set as corresponding contactor feedback signal (see [[Input and output signals>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.3 Input and output signals.WebHome]]). 428 428 429 429 To change the contactor feedback check parameters, select the menu "Protections → Contactor feedback check": 430 430 ... ... @@ -627,7 +627,7 @@ 627 627 628 628 * Enable – a flag to enable the protection; 629 629 * Logic count – a number of BMS Logic boards connected to the BMS Main 2.x; 630 -* Fast scan ning– a flag to scan BMS Logic boards fast (boards with addresses from 1 to “Logic count” are scanned; this mode reduces BMS system startup time);629 +* Fast scan – a flag to scan BMS Logic boards fast (boards with addresses from 1 to “Logic count” are scanned; this mode reduces BMS system startup time); 631 631 * Lock the error until the device is reset. 632 632 633 633 As a result of the operation of the protection from the mismatch of the number of BMS Logic boards, the "Logic count error" is generated. ... ... @@ -679,10 +679,6 @@ 679 679 In this section: 680 680 681 681 * Enable – a flag to enable the protection; 682 -* Algorithm: 683 -** Always; 684 -** On charging; 685 -** Except charging; 686 686 * Delay before setting the error, second; 687 687 * Delay before clearing the error, second; 688 688 * Lock the error until the device is reset. ... ... @@ -747,7 +747,7 @@ 747 747 * Lock the error until the device is reset; 748 748 * Errors – a section to select errors that should trigger General error. 749 749 750 -The general error flag is generated if at least one of the selected errors is generated during the “Delay before setting the error” time.745 +The critical error flag is generated if at least one of the selected errors is generated during the “Delay before setting the error” time. 751 751 752 752 The “General error” is cleared if there are no errors from selected list during the “Delay before clearing the error” time. 753 753
- 1739960999969-617.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -19.8 KB - Content
- 1739961158202-478.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -22.3 KB - Content