Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -10,7 +10,7 @@ 10 10 11 11 To change the current protection of the battery, select the menu "Protections → Overcurrent protection": 12 12 13 -[[image:173 2211959984-118.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="266" width="386"]]13 +[[image:1743588404359-971.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="325" width="450"]] 14 14 15 15 In this section: 16 16 ... ... @@ -21,6 +21,9 @@ 21 21 * Tolerant discharging current, А; 22 22 * Delay before setting the error, second; 23 23 * Delay before clearing the error, second; 24 +* Use other delays if the battery is discharging – a flag to enable alternative timings for battery discharging; 25 +* Discharging: Delay before setting the error, second; 26 +* Discharging: Delay before clearing the error, second; 24 24 * Lock the error until the device is reset – a flag to block the error until the board is restarted. 25 25 26 26 As a result of operation of the current protection, the "Overcurrent" error is generated. ... ... @@ -53,7 +53,7 @@ 53 53 * Enable – a flag to enable the protection; 54 54 * Minimum cell voltage, V; 55 55 * Tolerant cell voltage, V; 56 -* Check the open circuit voltage instead of the actual voltage – a flag to enable Uocv correction depending on cu; 59 +* Check the open circuit voltage instead of the actual voltage – a flag to enable U,,ocv,, correction depending on cell current and resistance; 57 57 * Delay before setting the error, second; 58 58 * Delay before clearing the error, second; 59 59 * Lock the error until the device is reset. ... ... @@ -84,6 +84,7 @@ 84 84 * Enable – a flag to enable the protection; 85 85 * Maximum cell voltage, V; 86 86 * Tolerant cell voltage, V; 90 +* Check the open circuit voltage instead of the actual voltage – a flag to enable U,,ocv,, correction depending on cell current and resistance; 87 87 * Delay before setting the error, second; 88 88 * Delay before clearing the error, second; 89 89 * Switch off the discharging relay on error – a flag to open the discharging relay when the "Overvoltage" error is generated;
- 1743588404359-971.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.7 KB - Content