46 46  
47 47  To change the battery protection parameters from low voltage on the cells, select the menu "Protections → Undervoltage protection":
48 48  
49 -[[image:1739960999969-617.png||alt="1739961158202-478.png" data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="228" width="351"]]
49 +[[image:1732212212350-294.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="207" width="359"]]
50 50  
51 51   In this section:
52 52  
... ... @@ -53,7 +53,6 @@
53 53  * Enable – a flag to enable the protection;
54 54  * Minimum cell voltage, V;
55 55  * Tolerant cell voltage, V;
56 -* Check the open circuit voltage instead of the actual voltage – a flag to enable Uocv correction depending on cu;
57 57  * Delay before setting the error, second;
58 58  * Delay before clearing the error, second;
59 59  * Lock the error until the device is reset.
... ... @@ -77,7 +77,7 @@
77 77  
78 78  To change the battery protection parameters from high voltage on the cells, select the menu "Protections → Overvoltage protection":
79 79  
80 -[[image:1739961158202-478.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="237" width="353"]]
79 +[[image:1732212357972-295.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="218" width="338"]]
81 81  
82 82  In this section:
83 83  
... ... @@ -627,7 +627,7 @@
627 627  
628 628  * Enable – a flag to enable the protection;
629 629  * Logic count – a number of BMS Logic boards connected to the BMS Main 2.x;
630 -* Fast scanning – a flag to scan BMS Logic boards fast (boards with addresses from 1 to “Logic count” are scanned; this mode reduces BMS system startup time);
629 +* Fast scan – a flag to scan BMS Logic boards fast (boards with addresses from 1 to “Logic count” are scanned; this mode reduces BMS system startup time);
631 631  * Lock the error until the device is reset.
632 632  
633 633  As a result of the operation of the protection from the mismatch of the number of BMS Logic boards, the "Logic count error" is generated.
... ... @@ -679,10 +679,6 @@
679 679  In this section:
680 680  
681 681  * Enable – a flag to enable the protection;
682 -* Algorithm:
683 -** Always;
684 -** On charging;
685 -** Except charging;
686 686  * Delay before setting the error, second;
687 687  * Delay before clearing the error, second;
688 688  * Lock the error until the device is reset.