Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -10,7 +10,7 @@ 10 10 11 11 To change the current protection of the battery, select the menu "Protections → Overcurrent protection": 12 12 13 -[[image:173 2211959984-118.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="266" width="386"]]13 +[[image:1743588404359-971.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="325" width="450"]] 14 14 15 15 In this section: 16 16 ... ... @@ -21,6 +21,7 @@ 21 21 * Tolerant discharging current, А; 22 22 * Delay before setting the error, second; 23 23 * Delay before clearing the error, second; 24 +* Use other delays if the battery is discharging – a flag to enable alternative timings for 24 24 * Lock the error until the device is reset – a flag to block the error until the board is restarted. 25 25 26 26 As a result of operation of the current protection, the "Overcurrent" error is generated. ... ... @@ -46,7 +46,7 @@ 46 46 47 47 To change the battery protection parameters from low voltage on the cells, select the menu "Protections → Undervoltage protection": 48 48 49 -[[image:173 2212212350-294.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="207" width="359"]]50 +[[image:1739960999969-617.png||alt="1739961158202-478.png" data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="228" width="351"]] 50 50 51 51 In this section: 52 52 ... ... @@ -53,6 +53,7 @@ 53 53 * Enable – a flag to enable the protection; 54 54 * Minimum cell voltage, V; 55 55 * Tolerant cell voltage, V; 57 +* Check the open circuit voltage instead of the actual voltage – a flag to enable U,,ocv,, correction depending on cell current and resistance; 56 56 * Delay before setting the error, second; 57 57 * Delay before clearing the error, second; 58 58 * Lock the error until the device is reset. ... ... @@ -76,7 +76,7 @@ 76 76 77 77 To change the battery protection parameters from high voltage on the cells, select the menu "Protections → Overvoltage protection": 78 78 79 -[[image:173 2212357972-295.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="218" width="338"]]81 +[[image:1739961158202-478.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="237" width="353"]] 80 80 81 81 In this section: 82 82 ... ... @@ -83,6 +83,7 @@ 83 83 * Enable – a flag to enable the protection; 84 84 * Maximum cell voltage, V; 85 85 * Tolerant cell voltage, V; 88 +* Check the open circuit voltage instead of the actual voltage – a flag to enable U,,ocv,, correction depending on cell current and resistance; 86 86 * Delay before setting the error, second; 87 87 * Delay before clearing the error, second; 88 88 * Switch off the discharging relay on error – a flag to open the discharging relay when the "Overvoltage" error is generated;
- 1743588404359-971.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.7 KB - Content