... ... @@ -423,7 +423,7 @@
423 423  
424 424  === Contactor feedback check ===
425 425  
426 -The BMS Main 2.x can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, one of the discrete input must be set as corresponding contactor feedback signal (see [[Input and output signals>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.3 Input and output signals.WebHome]]).
426 +The BMS Main 2.x can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, one of the discrete input must be set as corresponding contactor feedback signal (see [[3.3 Input and output signals>>path:/bin/view/drafts/BMS%20Main%202.1/3.%20Configuration/3.3%20Input%20and%20output%20signals/]]).
427 427  
428 428  To change the contactor feedback check parameters, select the menu "Protections → Contactor feedback check":
429 429  
... ... @@ -626,7 +626,7 @@
626 626  
627 627  * Enable – a flag to enable the protection;
628 628  * Logic count – a number of BMS Logic boards connected to the BMS Main 2.x;
629 -* Fast scanning – a flag to scan BMS Logic boards fast (boards with addresses from 1 to “Logic count” are scanned; this mode reduces BMS system startup time);
629 +* Fast scan – a flag to scan BMS Logic boards fast (boards with addresses from 1 to “Logic count” are scanned; this mode reduces BMS system startup time);
630 630  * Lock the error until the device is reset.
631 631  
632 632  As a result of the operation of the protection from the mismatch of the number of BMS Logic boards, the "Logic count error" is generated.
... ... @@ -678,10 +678,6 @@
678 678  In this section:
679 679  
680 680  * Enable – a flag to enable the protection;
681 -* Algorithm:
682 -** Always;
683 -** On charging;
684 -** Except charging;
685 685  * Delay before setting the error, second;
686 686  * Delay before clearing the error, second;
687 687  * Lock the error until the device is reset.
... ... @@ -746,7 +746,7 @@
746 746  * Lock the error until the device is reset;
747 747  * Errors – a section to select errors that should trigger General error.
748 748  
749 -The general error flag is generated if at least one of the selected errors is generated during the “Delay before setting the error” time.
745 +The critical error flag is generated if at least one of the selected errors is generated during the “Delay before setting the error” time.
750 750  
751 751  The “General error” is cleared if there are no errors from selected list during the “Delay before clearing the error” time.
752 752  