... ... @@ -46,7 +46,7 @@
46 46  
47 47  To change the battery protection parameters from low voltage on the cells, select the menu "Protections → Undervoltage protection":
48 48  
49 -[[image:1732212212350-294.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="207" width="359"]]
49 +[[image:1739960999969-617.png||alt="1739961158202-478.png" data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="228" width="351"]]
50 50  
51 51   In this section:
52 52  
... ... @@ -53,6 +53,7 @@
53 53  * Enable – a flag to enable the protection;
54 54  * Minimum cell voltage, V;
55 55  * Tolerant cell voltage, V;
56 +* Check the open circuit voltage instead of the actual voltage – a flag to enable Uocv correction depending on current ;
56 56  * Delay before setting the error, second;
57 57  * Delay before clearing the error, second;
58 58  * Lock the error until the device is reset.
... ... @@ -76,7 +76,7 @@
76 76  
77 77  To change the battery protection parameters from high voltage on the cells, select the menu "Protections → Overvoltage protection":
78 78  
79 -[[image:1732212357972-295.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="218" width="338"]]
80 +[[image:1739961158202-478.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="237" width="353"]]
80 80  
81 81  In this section:
82 82  
... ... @@ -626,7 +626,7 @@
626 626  
627 627  * Enable – a flag to enable the protection;
628 628  * Logic count – a number of BMS Logic boards connected to the BMS Main 2.x;
629 -* Fast scan – a flag to scan BMS Logic boards fast (boards with addresses from 1 to “Logic count” are scanned; this mode reduces BMS system startup time);
630 +* Fast scanning – a flag to scan BMS Logic boards fast (boards with addresses from 1 to “Logic count” are scanned; this mode reduces BMS system startup time);
630 630  * Lock the error until the device is reset.
631 631  
632 632  As a result of the operation of the protection from the mismatch of the number of BMS Logic boards, the "Logic count error" is generated.
... ... @@ -678,6 +678,10 @@
678 678  In this section:
679 679  
680 680  * Enable – a flag to enable the protection;
682 +* Algorithm:
683 +** Always;
684 +** On charging;
685 +** Except charging;
681 681  * Delay before setting the error, second;
682 682  * Delay before clearing the error, second;
683 683  * Lock the error until the device is reset.