Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -46,7 +46,7 @@ 46 46 47 47 To change the battery protection parameters from low voltage on the cells, select the menu "Protections → Undervoltage protection": 48 48 49 -[[image:173 2212212350-294.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="207" width="359"]]49 +[[image:1739960999969-617.png||alt="1739961158202-478.png" data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="228" width="351"]] 50 50 51 51 In this section: 52 52 ... ... @@ -53,6 +53,7 @@ 53 53 * Enable – a flag to enable the protection; 54 54 * Minimum cell voltage, V; 55 55 * Tolerant cell voltage, V; 56 +* Check the open circuit voltage instead of the actual voltage – a flag to enable Uocv correction depending on current ; 56 56 * Delay before setting the error, second; 57 57 * Delay before clearing the error, second; 58 58 * Lock the error until the device is reset. ... ... @@ -76,7 +76,7 @@ 76 76 77 77 To change the battery protection parameters from high voltage on the cells, select the menu "Protections → Overvoltage protection": 78 78 79 -[[image:173 2212357972-295.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="218" width="338"]]80 +[[image:1739961158202-478.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="237" width="353"]] 80 80 81 81 In this section: 82 82 ... ... @@ -626,7 +626,7 @@ 626 626 627 627 * Enable – a flag to enable the protection; 628 628 * Logic count – a number of BMS Logic boards connected to the BMS Main 2.x; 629 -* Fast scan – a flag to scan BMS Logic boards fast (boards with addresses from 1 to “Logic count” are scanned; this mode reduces BMS system startup time); 630 +* Fast scanning – a flag to scan BMS Logic boards fast (boards with addresses from 1 to “Logic count” are scanned; this mode reduces BMS system startup time); 630 630 * Lock the error until the device is reset. 631 631 632 632 As a result of the operation of the protection from the mismatch of the number of BMS Logic boards, the "Logic count error" is generated. ... ... @@ -678,6 +678,10 @@ 678 678 In this section: 679 679 680 680 * Enable – a flag to enable the protection; 682 +* Algorithm: 683 +** Always; 684 +** On charging; 685 +** Except charging; 681 681 * Delay before setting the error, second; 682 682 * Delay before clearing the error, second; 683 683 * Lock the error until the device is reset.
- 1739960999969-617.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.8 KB - Content
- 1739961158202-478.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.3 KB - Content