Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -6,9 +6,8 @@ 6 6 7 7 [[Overcurrent protection settings>>image:1732211959984-118.png||data-xwiki-image-style-alignment="center" height="266" width="386"]] 8 8 9 + In this section: 9 9 10 -In this section: 11 - 12 12 * Enable – a flag to enable the protection; 13 13 * Maximum charging current, А; 14 14 * Tolerant charging current, А; ... ... @@ -32,7 +32,7 @@ 32 32 33 33 (% class="box infomessage" %) 34 34 ((( 35 -If there is the "Overcurrent" error, the charging relay and discharging relay open.34 +If there is the "Overcurrent" error, the charging and discharging relay open. 36 36 ))) 37 37 38 38 == 3.6.2 Undervoltage protection == ... ... @@ -98,35 +98,230 @@ 98 98 If there is the "Overvoltage" error, the charging relay and discharging relay opens (if the “Switch off the discharging relay on error” flag is set). 99 99 ))) 100 100 101 -3.6.4 Low temperature protection 100 +== 3.6.4 Low temperature protection == 102 102 103 - 3.6.5 Hightemperature protection102 +The board implements battery protection from too low temperature. 104 104 105 - 3.6.6Battery cover protection104 +To change the battery protection parameters from low temperature, select the menu "Protections → Low temperature protection": 106 106 107 -3.6.7 High humidity protection 108 108 109 -3.6.8 Water protection 110 -3.6.9 Current sensor error 111 -3.6.10 Short circuit protection 112 -3.6.11 Contactor high temperature protection 113 -3.6.12 Unallowable charging protection 114 -3.6.13 Stuck contactor protection 115 -3.6.14 Contactor feedback check 116 -3.6.15 Charging contactor cycles protection 117 -3.6.16 Discharging contactor cycles protection 118 -3.6.17 Temperature sensor error 119 -3.6.18 Logic high temperature protection 120 -3.6.19 Logic offline protection 121 -3.6.20 Cell count protection 122 -3.6.21 Logic count protection 123 -3.6.22 WDT protection 124 -3.6.23 Insulation monitoring 125 -3.6.24 Critical error parameters 126 -3.6.25 General error parameters 127 -3.6.26 Low SOC signal 128 -3.6.27 High charging current signal 129 -Heater control 130 -Heater (AUX) control 131 -Cooler control 132 -Fault simulation 107 +In this section: 108 + 109 +* Enable – a flag to enable the protection; 110 +* Minimum charging temperature, °C; 111 +* Tolerant charging temperature, °C; 112 +* Minimum discharging temperature, °C; 113 +* Tolerant discharging temperature, °C; 114 +* Delay before setting the error, second; 115 +* Delay before clearing the error, second; 116 +* Lock the error until the device is reset. 117 + 118 +As a result of the operation of the battery protection from low temperature, the "Low CH temperature" or “Low DCH temperature” error is generated. 119 + 120 +Error generation conditions: 121 + 122 +* the minimum temperature among all cells of the battery is less than the “Minimum charging (discharging) temperature” value for the “Delay before setting the error” time. 123 + 124 +Conditions for removing the error: 125 + 126 +* the minimum temperature among all cells of the battery is greater than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time. 127 + 128 +(% class="box infomessage" %) 129 +((( 130 +If there is the "Low CH temperature" error, the charging relay opens. 131 +If there is the "Low DCH temperature" error, the discharging relay opens. 132 +))) 133 + 134 +== 3.6.5 High temperature protection == 135 + 136 +The board implements battery protection from too high temperature. 137 + 138 +To change the battery protection parameters from high temperature, select the menu "Protections → High temperature protection": 139 + 140 + 141 +In this section: 142 + 143 +* Enable – a flag to enable the protection; 144 +* Maximum charging temperature, °C; 145 +* Tolerant charging temperature, °C; 146 +* Maximum discharging temperature, °C; 147 +* Tolerant discharging temperature, °C; 148 +* Delay before setting the error, second; 149 +* Delay before clearing the error, second; 150 +* Lock the error until the device is reset. 151 + 152 +As a result of the operation of the battery protection from high temperature, the "High CH temperature" or “High DCH temperature” error is generated. 153 + 154 +Error generation conditions: 155 + 156 +* the maximum temperature among all cells of the battery is greater than the “Maximum charging (discharging) temperature” value for the “Delay before setting the error” time. 157 + 158 +Conditions for removing the error: 159 + 160 +* the maximum temperature among all cells of the battery is less than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time. 161 + 162 +(% class="box infomessage" %) 163 +((( 164 +If there is the "High CH temperature" error, the charging relay opens. 165 +If there is the "High DCH temperature" error, the discharging relay opens. 166 +))) 167 + 168 +== 3.6.6 Battery cover protection == 169 + 170 +To change the protection parameters from opening the battery cover, select the menu "Protections → Battery cover protection": 171 + 172 +In this section: 173 + 174 +* Enable – a flag to enable the protection; 175 +* Delay before setting the error, second; 176 +* Delay before clearing the error, second; 177 +* Lock the error until the device is reset. 178 + 179 +As a result of the operation of the protection against opening the battery cover, the “Battery cover error” is generated. 180 + 181 +Error generation conditions: 182 + 183 +* there is a signal from the battery cover during the “Delay before setting the error” time. 184 + 185 +Conditions for removing the error: 186 + 187 +* no signal from the battery cover during the “Delay before clearing the error” time. 188 + 189 +(% class="box warningmessage" %) 190 +((( 191 +**If there is the "Battery cover error", the “Critical error” is generated and all relays open.** 192 +))) 193 + 194 +== 3.6.7 High humidity protection == 195 + 196 +The board can protect the battery from high humidity and water. 197 + 198 +To change the protection parameters of the battery from high humidity, select the menu "Protections → High humidity protection": 199 + 200 + 201 +In this section: 202 + 203 +* Enable – a flag to enable the protection; 204 +* Maximum humidty, RH%; 205 +* Tolerant humidty, RH%; 206 +* Delay before setting the error, second; 207 +* Delay before clearing the error, second; 208 +* Lock the error until the device is reset. 209 + 210 +As a result of the operation of the battery protection from high humidity, the "High humidity" error is generated. 211 + 212 +Error generation conditions: 213 + 214 +* the measured humidity is greater than “Maximum humidity” during the “Delay before setting the error” time. 215 + 216 +Conditions for removing the error: 217 + 218 +* the measured humidity is less than the “Tolerant humidity” during the “Delay before clearing the error” time. 219 + 220 +(% class="box infomessage" %) 221 +((( 222 +If there is the "High humidity" error, no action is taken. The error is indicative. 223 +))) 224 + 225 +== 3.6.8 Water protection == 226 + 227 +To change the protection parameters of the battery from water, select the menu "Protections → Water protection": 228 + 229 + 230 +In this section: 231 + 232 +* Enable – a flag to enable the protection; 233 +* Maximum (water) humidty, RH%; 234 +* Tolerant humidity, RH%; 235 +* Delay before setting the error, second; 236 +* Delay before clearing the error, second; 237 +* Lock the error until the device is reset. 238 + 239 +As a result of the operation of the battery protection from water, the "Water" error is generated. 240 + 241 +Error generation conditions: 242 + 243 +* the measured humidity is greater than the “Maximum (water) humidity” value during the “Delay before setting the error” time. 244 + 245 +Conditions for removing the error: 246 + 247 +* the measured humidity is less than the “Tolerant humidity” value during the “Delay before clearing the error” time. 248 + 249 +(% class="box warningmessage" %) 250 +((( 251 +**If there is the “Water” error, the “Critical error” is generated and all relays open.** 252 +))) 253 + 254 +== 3.6.9 Current sensor error == 255 + 256 +The board is implemented to check the current sensor connection circuits. The circuits are checked for breakage and short-circuit to the +5 V supply line. 257 + 258 +To change the test parameters of the current sensor connection circuits, select the menu "Protections → Current sensor error": 259 + 260 + 261 +In this section: 262 + 263 +* Enable – a flag to enable the protection; 264 +* Maximum voltage, V; 265 +* Minimum voltage, V; 266 +* Hysteresis voltage – a hysteresis value to clear the error, V; 267 +* Delay before setting the error, second; 268 +* Delay before clearing the error, second; 269 +* Lock the error until the device is reset. 270 + 271 +If there is an open or short circuit connection of a current sensor, the "Current sensor error" is generated. 272 + 273 +Error generation conditions: 274 + 275 +* the voltage in the signal line or zero level line of the current sensor is greater than the “Maximum voltage” value during the “Delay before setting the error” time; 276 +* the voltage in the signal line or zero level line of the current sensor is less than the “Minimum voltage” value during the “Delay before setting the error” time. 277 + 278 +Conditions for removing the error: 279 + 280 +* the voltage in the signal line or zero level line of the current sensor is in range from (Minimum voltage + Hysteresis voltage) to (Maximum voltage - Hysteresis voltage) during the “Delay before clearing the error” time. 281 + 282 +**If there is the “Current sensor error”, the “Critical error” is generated and all relays open.** 283 + 284 +== 3.6.10 Short circuit protection == 285 + 286 +== 3.6.11 Contactor high temperature protection == 287 + 288 +== 3.6.12 Unallowable charging protection == 289 + 290 +== 3.6.13 Stuck contactor protection == 291 + 292 +== 3.6.14 Contactor feedback check == 293 + 294 +== 3.6.15 Charging contactor cycles protection == 295 + 296 +== 3.6.16 Discharging contactor cycles protection == 297 + 298 +== 3.6.17 Temperature sensor error == 299 + 300 +== 3.6.18 Logic high temperature protection == 301 + 302 +== 3.6.19 Logic offline protection == 303 + 304 +== 3.6.20 Cell count protection == 305 + 306 +== 3.6.21 Logic count protection == 307 + 308 +== 3.6.22 WDT protection == 309 + 310 +== 3.6.23 Insulation monitoring == 311 + 312 +== 3.6.24 Critical error parameters == 313 + 314 +== 3.6.25 General error parameters == 315 + 316 +== 3.6.26 Low SOC signal == 317 + 318 +== 3.6.27 High charging current signal == 319 + 320 +== 3.6.28 Heater control == 321 + 322 +== 3.6.29 Heater (AUX) control == 323 + 324 +== 3.6.30 Cooler control == 325 + 326 +== 3.6.31 Fault simulation ==