Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -6,9 +6,8 @@ 6 6 7 7 [[Overcurrent protection settings>>image:1732211959984-118.png||data-xwiki-image-style-alignment="center" height="266" width="386"]] 8 8 9 + In this section: 9 9 10 -In this section: 11 - 12 12 * Enable – a flag to enable the protection; 13 13 * Maximum charging current, А; 14 14 * Tolerant charging current, А; ... ... @@ -32,7 +32,7 @@ 32 32 33 33 (% class="box infomessage" %) 34 34 ((( 35 -If there is the "Overcurrent" error, the charging relay and discharging relay open.34 +If there is the "Overcurrent" error, the charging and discharging relay open. 36 36 ))) 37 37 38 38 == 3.6.2 Undervoltage protection == ... ... @@ -98,35 +98,172 @@ 98 98 If there is the "Overvoltage" error, the charging relay and discharging relay opens (if the “Switch off the discharging relay on error” flag is set). 99 99 ))) 100 100 101 -3.6.4 Low temperature protection 100 +== 3.6.4 Low temperature protection == 102 102 103 - 3.6.5 Hightemperature protection102 +The board implements battery protection from too low temperature. 104 104 105 - 3.6.6Battery cover protection104 +To change the battery protection parameters from low temperature, select the menu "Protections → Low temperature protection": 106 106 107 -3.6.7 High humidity protection 108 108 109 -3.6.8 Water protection 110 -3.6.9 Current sensor error 111 -3.6.10 Short circuit protection 112 -3.6.11 Contactor high temperature protection 113 -3.6.12 Unallowable charging protection 114 -3.6.13 Stuck contactor protection 115 -3.6.14 Contactor feedback check 116 -3.6.15 Charging contactor cycles protection 117 -3.6.16 Discharging contactor cycles protection 118 -3.6.17 Temperature sensor error 119 -3.6.18 Logic high temperature protection 120 -3.6.19 Logic offline protection 121 -3.6.20 Cell count protection 122 -3.6.21 Logic count protection 123 -3.6.22 WDT protection 124 -3.6.23 Insulation monitoring 125 -3.6.24 Critical error parameters 126 -3.6.25 General error parameters 127 -3.6.26 Low SOC signal 128 -3.6.27 High charging current signal 129 -Heater control 130 -Heater (AUX) control 131 -Cooler control 132 -Fault simulation 107 +In this section: 108 + 109 +* Enable – a flag to enable the protection; 110 +* Minimum charging temperature, °C; 111 +* Tolerant charging temperature, °C; 112 +* Minimum discharging temperature, °C; 113 +* Tolerant discharging temperature, °C; 114 +* Delay before setting the error, second; 115 +* Delay before clearing the error, second; 116 +* Lock the error until the device is reset. 117 + 118 +As a result of the operation of the battery protection from low temperature, the "Low CH temperature" or “Low DCH temperature” error is generated. 119 + 120 +Error generation conditions: 121 + 122 +* the minimum temperature among all cells of the battery is less than the “Minimum charging (discharging) temperature” value for the “Delay before setting the error” time. 123 + 124 +Conditions for removing the error: 125 + 126 +* the minimum temperature among all cells of the battery is greater than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time. 127 + 128 +(% class="box infomessage" %) 129 +((( 130 +If there is the "Low CH temperature" error, the charging relay opens. 131 +If there is the "Low DCH temperature" error, the discharging relay opens. 132 +))) 133 + 134 +== 3.6.5 High temperature protection == 135 + 136 +The board implements battery protection from too high temperature. 137 + 138 +To change the battery protection parameters from high temperature, select the menu "Protections → High temperature protection": 139 + 140 + 141 +In this section: 142 + 143 +* Enable – a flag to enable the protection; 144 +* Maximum charging temperature, °C; 145 +* Tolerant charging temperature, °C; 146 +* Maximum discharging temperature, °C; 147 +* Tolerant discharging temperature, °C; 148 +* Delay before setting the error, second; 149 +* Delay before clearing the error, second; 150 +* Lock the error until the device is reset. 151 + 152 +As a result of the operation of the battery protection from high temperature, the "High CH temperature" or “High DCH temperature” error is generated. 153 + 154 +Error generation conditions: 155 + 156 +* the maximum temperature among all cells of the battery is greater than the “Maximum charging (discharging) temperature” value for the “Delay before setting the error” time. 157 + 158 +Conditions for removing the error: 159 + 160 +* the maximum temperature among all cells of the battery is less than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time. 161 + 162 +(% class="box infomessage" %) 163 +((( 164 +If there is the "High CH temperature" error, the charging relay opens. 165 +If there is the "High DCH temperature" error, the discharging relay opens. 166 +))) 167 + 168 +== 3.6.6 Battery cover protection == 169 + 170 +To change the protection parameters from opening the battery cover, select the menu "Protections → Battery cover protection": 171 + 172 +In this section: 173 + 174 +* Enable – a flag to enable the protection; 175 +* Delay before setting the error, second; 176 +* Delay before clearing the error, second; 177 +* Lock the error until the device is reset. 178 + 179 +As a result of the operation of the protection against opening the battery cover, the “Battery cover error” is generated. 180 + 181 +Error generation conditions: 182 + 183 +* there is a signal from the battery cover during the “Delay before setting the error” time. 184 + 185 +Conditions for removing the error: 186 + 187 +* no signal from the battery cover during the “Delay before clearing the error” time. 188 + 189 +(% class="box warningmessage" %) 190 +((( 191 +**If there is the "Battery cover error", the “Critical error” is generated and all relays open.** 192 +))) 193 + 194 +== 3.6.7 High humidity protection == 195 + 196 +The board can protect the battery from high humidity and water. 197 + 198 +To change the protection parameters of the battery from high humidity, select the menu "Protections → High humidity protection": 199 + 200 +In this section: 201 + 202 +* Enable – a flag to enable the protection; 203 +* Maximum humidty, RH%; 204 +* Tolerant humidty, RH%; 205 +* Delay before setting the error, second; 206 +* Delay before clearing the error, second; 207 +* Lock the error until the device is reset. 208 + 209 +As a result of the operation of the battery protection from high humidity, the "High humidity" error is generated. 210 + 211 +Error generation conditions: 212 + 213 +* the measured humidity is greater than “Maximum humidity” during the “Delay before setting the error” time. 214 + 215 +Conditions for removing the error: 216 + 217 +* the measured humidity is less than the “Tolerant humidity” during the “Delay before clearing the error” time. 218 + 219 +If there is the "High humidity" error, no action is taken. The error is indicative. 220 + 221 + 222 +== 3.6.8 Water protection == 223 + 224 +== 3.6.9 Current sensor error == 225 + 226 +== 3.6.10 Short circuit protection == 227 + 228 +== 3.6.11 Contactor high temperature protection == 229 + 230 +== 3.6.12 Unallowable charging protection == 231 + 232 +== 3.6.13 Stuck contactor protection == 233 + 234 +== 3.6.14 Contactor feedback check == 235 + 236 +== 3.6.15 Charging contactor cycles protection == 237 + 238 +== 3.6.16 Discharging contactor cycles protection == 239 + 240 +== 3.6.17 Temperature sensor error == 241 + 242 +== 3.6.18 Logic high temperature protection == 243 + 244 +== 3.6.19 Logic offline protection == 245 + 246 +== 3.6.20 Cell count protection == 247 + 248 +== 3.6.21 Logic count protection == 249 + 250 +== 3.6.22 WDT protection == 251 + 252 +== 3.6.23 Insulation monitoring == 253 + 254 +== 3.6.24 Critical error parameters == 255 + 256 +== 3.6.25 General error parameters == 257 + 258 +== 3.6.26 Low SOC signal == 259 + 260 +== 3.6.27 High charging current signal == 261 + 262 +== 3.6.28 Heater control == 263 + 264 +== 3.6.29 Heater (AUX) control == 265 + 266 +== 3.6.30 Cooler control == 267 + 268 +== 3.6.31 Fault simulation ==