Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -98,35 +98,146 @@ 98 98 If there is the "Overvoltage" error, the charging relay and discharging relay opens (if the “Switch off the discharging relay on error” flag is set). 99 99 ))) 100 100 101 -3.6.4 Low temperature protection 101 +== 3.6.4 Low temperature protection == 102 102 103 - 3.6.5 Hightemperature protection103 +The board implements battery protection from too low temperature. 104 104 105 - 3.6.6Battery cover protection105 +To change the battery protection parameters from low temperature, select the menu "Protections → Low temperature protection": 106 106 107 -3.6.7 High humidity protection 108 108 109 -3.6.8 Water protection 110 -3.6.9 Current sensor error 111 -3.6.10 Short circuit protection 112 -3.6.11 Contactor high temperature protection 113 -3.6.12 Unallowable charging protection 114 -3.6.13 Stuck contactor protection 115 -3.6.14 Contactor feedback check 116 -3.6.15 Charging contactor cycles protection 117 -3.6.16 Discharging contactor cycles protection 118 -3.6.17 Temperature sensor error 119 -3.6.18 Logic high temperature protection 120 -3.6.19 Logic offline protection 121 -3.6.20 Cell count protection 122 -3.6.21 Logic count protection 123 -3.6.WDT protection 124 -Insulation monitoring 125 -Critical error parameters 126 -General error parameters 127 -Low SOC signal 128 -High charging current signal 129 -Heater control 130 -Heater (AUX) control 131 -Cooler control 132 -Fault simulation 108 +In this section: 109 + 110 +* Enable – a flag to enable the protection; 111 +* Minimum charging temperature, °C; 112 +* Tolerant charging temperature, °C; 113 +* Minimum discharging temperature, °C; 114 +* Tolerant discharging temperature, °C; 115 +* Delay before setting the error, second; 116 +* Delay before clearing the error, second; 117 +* Lock the error until the device is reset. 118 + 119 +As a result of the operation of the battery protection from low temperature, the "Low CH temperature" or “Low DCH temperature” error is generated. 120 + 121 +Error generation conditions: 122 + 123 +* the minimum temperature among all cells of the battery is less than the “Minimum charging (discharging) temperature” value for the “Delay before setting the error” time. 124 + 125 +Conditions for removing the error: 126 + 127 +* the minimum temperature among all cells of the battery is greater than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time. 128 + 129 +(% class="box infomessage" %) 130 +((( 131 +If there is the "Low CH temperature" error, the charging relay opens. 132 +If there is the "Low DCH temperature" error, the discharging relay opens. 133 +))) 134 + 135 +== 3.6.5 High temperature protection == 136 + 137 +The board implements battery protection from too high temperature. 138 + 139 +To change the battery protection parameters from high temperature, select the menu "Protections → High temperature protection": 140 + 141 + 142 +In this section: 143 + 144 +* Enable – a flag to enable the protection; 145 +* Maximum charging temperature, °C; 146 +* Tolerant charging temperature, °C; 147 +* Maximum discharging temperature, °C; 148 +* Tolerant discharging temperature, °C; 149 +* Delay before setting the error, second; 150 +* Delay before clearing the error, second; 151 +* Lock the error until the device is reset. 152 + 153 +As a result of the operation of the battery protection from high temperature, the "High CH temperature" or “High DCH temperature” error is generated. 154 + 155 +Error generation conditions: 156 + 157 +* the maximum temperature among all cells of the battery is greater than the “Maximum charging (discharging) temperature” value for the “Delay before setting the error” time. 158 + 159 +Conditions for removing the error: 160 + 161 +* the maximum temperature among all cells of the battery is less than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time. 162 + 163 +(% class="box infomessage" %) 164 +((( 165 +If there is the "High CH temperature" error, the charging relay opens. 166 +If there is the "High DCH temperature" error, the discharging relay opens. 167 +))) 168 + 169 +== 3.6.6 Battery cover protection == 170 + 171 +To change the protection parameters from opening the battery cover, select the menu "Protections → Battery cover protection": 172 + 173 +In this section: 174 + 175 +* Enable – a flag to enable the protection; 176 +* Delay before setting the error, second; 177 +* Delay before clearing the error, second; 178 +* Lock the error until the device is reset. 179 + 180 +As a result of the operation of the protection against opening the battery cover, the “Battery cover error” is generated. 181 + 182 +Error generation conditions: 183 + 184 +* there is a signal from the battery cover during the “Delay before setting the error” time. 185 + 186 +Conditions for removing the error: 187 + 188 +* no signal from the battery cover during the “Delay before clearing the error” time. 189 + 190 +(% class="box warningmessage" %) 191 +((( 192 +**If there is the "Battery cover error", the “Critical error” is generated and all relays open.** 193 +))) 194 + 195 +== 3.6.7 High humidity protection == 196 + 197 +== 3.6.8 Water protection == 198 + 199 +== 3.6.9 Current sensor error == 200 + 201 +== 3.6.10 Short circuit protection == 202 + 203 +== 3.6.11 Contactor high temperature protection == 204 + 205 +== 3.6.12 Unallowable charging protection == 206 + 207 +== 3.6.13 Stuck contactor protection == 208 + 209 +== 3.6.14 Contactor feedback check == 210 + 211 +== 3.6.15 Charging contactor cycles protection == 212 + 213 +== 3.6.16 Discharging contactor cycles protection == 214 + 215 +== 3.6.17 Temperature sensor error == 216 + 217 +== 3.6.18 Logic high temperature protection == 218 + 219 +== 3.6.19 Logic offline protection == 220 + 221 +== 3.6.20 Cell count protection == 222 + 223 +== 3.6.21 Logic count protection == 224 + 225 +== 3.6.22 WDT protection == 226 + 227 +== 3.6.23 Insulation monitoring == 228 + 229 +== 3.6.24 Critical error parameters == 230 + 231 +== 3.6.25 General error parameters == 232 + 233 +== 3.6.26 Low SOC signal == 234 + 235 +== 3.6.27 High charging current signal == 236 + 237 +== 3.6.28 Heater control == 238 + 239 +== 3.6.29 Heater (AUX) control == 240 + 241 +== 3.6.30 Cooler control == 242 + 243 +== 3.6.31 Fault simulation ==