Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -98,35 +98,120 @@ 98 98 If there is the "Overvoltage" error, the charging relay and discharging relay opens (if the “Switch off the discharging relay on error” flag is set). 99 99 ))) 100 100 101 -3.6.4 Low temperature protection 101 +== 3.6.4 Low temperature protection == 102 102 103 - 3.6.5 Hightemperature protection103 +The board implements battery protection from too low temperature. 104 104 105 - 3.6.6Battery cover protection105 +To change the battery protection parameters from low temperature, select the menu "Protections → Low temperature protection": 106 106 107 -3.6.7 High humidity protection 108 108 109 -3.6.8 Water protection 110 -3.6.9 Current sensor error 111 -3.6.10 Short circuit protection 112 -3.6.11 Contactor high temperature protection 113 -3.6.12 Unallowable charging protection 114 -3.6.13 Stuck contactor protection 115 -3.6.14 Contactor feedback check 116 -3.6.15 Charging contactor cycles protection 117 -3.6.16 Discharging contactor cycles protection 118 -3.6.17 Temperature sensor error 119 -3.6.18 Logic high temperature protection 120 -3.6.19 Logic offline protection 121 -3.6.20 Cell count protection 122 -3.6.21 Logic count protection 123 -3.6.WDT protection 124 -Insulation monitoring 125 -Critical error parameters 126 -General error parameters 127 -Low SOC signal 128 -High charging current signal 129 -Heater control 130 -Heater (AUX) control 131 -Cooler control 132 -Fault simulation 108 +In this section: 109 + 110 +* Enable – a flag to enable the protection; 111 +* Minimum charging temperature, °C; 112 +* Tolerant charging temperature, °C; 113 +* Minimum discharging temperature, °C; 114 +* Tolerant discharging temperature, °C; 115 +* Delay before setting the error, second; 116 +* Delay before clearing the error, second; 117 +* Lock the error until the device is reset. 118 + 119 +As a result of the operation of the battery protection from low temperature, the "Low CH temperature" or “Low DCH temperature” error is generated. 120 + 121 +Error generation conditions: 122 + 123 +* the minimum temperature among all cells of the battery is less than the “Minimum charging (discharging) temperature” value for the “Delay before setting the error” time. 124 + 125 +Conditions for removing the error: 126 + 127 +* the minimum temperature among all cells of the battery is greater than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time. 128 + 129 +(% class="box infomessage" %) 130 +((( 131 +If there is the "Low CH temperature" error, the charging relay opens. If there is the "Low DCH temperature" error, the discharging relay opens. 132 +))) 133 + 134 +== 3.6.5 High temperature protection == 135 + 136 +The board implements battery protection from too high temperature. 137 + 138 +To change the battery protection parameters from high temperature, select the menu "Protections → High temperature protection": 139 + 140 +In this section: 141 + 142 +* Enable – a flag to enable the protection; 143 +* Maximum charging temperature, °C; 144 +* Tolerant charging temperature, °C; 145 +* Maximum discharging temperature, °C; 146 +* Tolerant discharging temperature, °C; 147 +* Delay before setting the error, second; 148 +* Delay before clearing the error, second; 149 +* Lock the error until the device is reset. 150 + 151 +As a result of the operation of the battery protection from high temperature, the "High CH temperature" or “High DCH temperature” error is generated. 152 + 153 +Error generation conditions: 154 + 155 +* the maximum temperature among all cells of the battery is greater than the “Maximum charging (discharging) temperature” value for the “Delay before setting the error” time. 156 + 157 +Conditions for removing the error: 158 + 159 +* the maximum temperature among all cells of the battery is less than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time. 160 + 161 +(% class="box infomessage" %) 162 +((( 163 +If there is the "High CH temperature" error, the charging relay opens. 164 +If there is the "High DCH temperature" error, the discharging relay opens. 165 +))) 166 + 167 +== 3.6.6 Battery cover protection == 168 + 169 +== 3.6.7 High humidity protection == 170 + 171 +== 3.6.8 Water protection == 172 + 173 +== 3.6.9 Current sensor error == 174 + 175 +== 3.6.10 Short circuit protection == 176 + 177 +== 3.6.11 Contactor high temperature protection == 178 + 179 +== 3.6.12 Unallowable charging protection == 180 + 181 +== 3.6.13 Stuck contactor protection == 182 + 183 +== 3.6.14 Contactor feedback check == 184 + 185 +== 3.6.15 Charging contactor cycles protection == 186 + 187 +== 3.6.16 Discharging contactor cycles protection == 188 + 189 +== 3.6.17 Temperature sensor error == 190 + 191 +== 3.6.18 Logic high temperature protection == 192 + 193 +== 3.6.19 Logic offline protection == 194 + 195 +== 3.6.20 Cell count protection == 196 + 197 +== 3.6.21 Logic count protection == 198 + 199 +== 3.6.22 WDT protection == 200 + 201 +== 3.6.23 Insulation monitoring == 202 + 203 +== 3.6.24 Critical error parameters == 204 + 205 +== 3.6.25 General error parameters == 206 + 207 +== 3.6.26 Low SOC signal == 208 + 209 +== 3.6.27 High charging current signal == 210 + 211 +== 3.6.28 Heater control == 212 + 213 +== 3.6.29 Heater (AUX) control == 214 + 215 +== 3.6.30 Cooler control == 216 + 217 +== 3.6.31 Fault simulation ==