Changes for page 3.6 Battery protection
Last modified by Admin on 2025/04/09 12:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -67,66 +67,4 @@ 67 67 If there is the "Undervoltage" error, the discharging relay opens. 68 68 ))) 69 69 70 -3.6.3 Overvoltage protection 71 - 72 -To change the battery protection parameters from high voltage on the cells, select the menu "Protections → Overvoltage protection": 73 - 74 -[[image:1732212357972-295.png]] 75 - 76 -In this section: 77 - 78 -* Enable – a flag to enable the protection; 79 -* Maximum cell voltage, V; 80 -* Tolerant cell voltage, V; 81 -* Delay before setting the error, second; 82 -* Delay before clearing the error, second; 83 -* Switch off the discharging relay on error – a flag to open the discharging relay when the "Overvoltage" error is generated; 84 -* Lock the error until the device is reset. 85 - 86 -As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated. 87 - 88 -Error generation conditions: 89 - 90 -* the maximum voltage among all cells of the battery is greater than the “Maximum cell voltage” value for the “Delay before setting the error” time. 91 - 92 -Conditions for removing the error: 93 - 94 -* the maximum voltage among all cells of the battery is less than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 95 - 96 -(% class="box infomessage" %) 97 -((( 98 -If there is the "Overvoltage" error, the charging relay and discharging relay opens (if the “Switch off the discharging relay on error” flag is set). 99 -))) 100 - 101 -3.6.4 Low temperature protection 102 - 103 -3.6.5 High temperature protection 104 - 105 -3.6.6 Battery cover protection 106 - 107 -3.6.7 High humidity protection 108 - 109 -3.6.8 Water protection 110 -3.6.9 Current sensor error 111 -3.6.10 Short circuit protection 112 -3.6.11 Contactor high temperature protection 113 -3.6.12 Unallowable charging protection 114 -3.6.13 Stuck contactor protection 115 -3.6.14 Contactor feedback check 116 -3.6.15 Charging contactor cycles protection 117 -3.6.16 Discharging contactor cycles protection 118 -3.6.17 Temperature sensor error 119 -3.6.18 Logic high temperature protection 120 -3.6.19 Logic offline protection 121 -3.6.20 Cell count protection 122 -3.6.21 Logic count protection 123 -3.6.WDT protection 124 -Insulation monitoring 125 -Critical error parameters 126 -General error parameters 127 -Low SOC signal 128 -High charging current signal 129 -Heater control 130 -Heater (AUX) control 131 -Cooler control 132 -Fault simulation 70 +
- 1732212357972-295.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -19.5 KB - Content