... ... @@ -67,37 +67,4 @@
67 67  If there is the "Undervoltage" error, the discharging relay opens.
68 68  )))
69 69  
70 -3.6.3 Overvoltage protection
71 -
72 -To change the battery protection parameters from high voltage on the cells, select the menu "Protections → Overvoltage protection":
73 -
74 -[[image:1732212357972-295.png]]
75 -
76 -In this section:
77 -
78 -* Enable – a flag to enable the protection;
79 -* Maximum cell voltage, V;
80 -* Tolerant cell voltage, V;
81 -* Delay before setting the error, second;
82 -* Delay before clearing the error, second;
83 -* Switch off the discharging relay on error – a flag to open the discharging relay when the "Overvoltage" error is generated;
84 -* Lock the error until the device is reset.
85 -
86 -As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated.
87 -
88 -Error generation conditions:
89 -
90 -* the maximum voltage among all cells of the battery is greater than the “Maximum cell voltage” value for the “Delay before setting the error” time.
91 -
92 -Conditions for removing the error:
93 -
94 -* the maximum voltage among all cells of the battery is less than the “Tolerant cell voltage” value for the “Delay before clearing the error” time.
95 -
96 -(% class="box infomessage" %)
97 -(((
98 -If there is the "Overvoltage" error, the charging relay and discharging relay opens (if the “Switch off the discharging relay on error” flag is set).
99 -)))
100 -
101 -3.6.4 Low temperature protection
102 -
103 -3.6.5 High temperature protecti